| Marca | ROCKWILL |
| Numero modello | Single-phase Vacuum Recloser (Reclosure) Wholesaler-15.6kV |
| tensione nominale | 15.6kV |
| corrente nominale | 1250A |
| corrente di cortocircuito nominale | 25kA |
| tensione di prova a frequenza industriale | 60kV/min |
| tensione di impulso fulmineo nominale | 125kV |
| Chiusura manuale | Yes |
| Serie | RCW |
As a pioneering original equipment manufacturer (OEM) in China’s recloser/reclosure industry, we have accumulated decades of R&D expertise, taken the lead in establishing the original industry standards, built a fully independent end-to-end production system, and delivered reliable product solutions for power grid construction.
The 15.6kV Single-phase outdoor Automatic Smart recloser/reclosure is an intelligent outdoor switching device specifically designed for medium-voltage distribution networks. Using vacuum as the arc-extinguishing medium, this equipment can quickly interrupt fault currents and effectively isolate short-circuits, overloads, and other faults in the distribution grid.
It features an automatic reclosing function that restores power supply automatically after fault elimination, significantly reducing power outage time and improving power supply reliability. With its compact and rugged outdoor structure design, it adapts to various harsh natural environments—stable operation in high temperatures, severe cold, high humidity, or sandy conditions—making it a vital device for ensuring safe and efficient operation of medium-voltage power lines.

High-efficiency Arc Extinguishing Performance
Adopting vacuum arc extinguishing technology, it features strong insulation and rapid arc extinction. It prevents arc reignition, extends the equipment's service life, and reduces maintenance costs.
Precise Automatic Reclosing
Automatically closes the circuit according to the preset program. It can distinguish between transient and permanent faults. For transient faults, it restores power supply rapidly; for permanent faults, it locks immediately to minimize the power outage scope.
Excellent Environmental Adaptability
With a high-strength and corrosion-resistant outer shell and internal protective treatment, it can operate stably in harsh environments, adapting to temperatures ranging from -40°C to +70°C.
Intelligent Monitoring and Remote Control
It can monitor key parameters such as current and voltage in real-time and upload data. Supporting remote opening and closing operations, it improves fault handling efficiency and the intelligent level of grid operation and maintenance.
High Safety and Reliability
Equipped with complete mechanical and electrical interlocking devices to prevent misoperation, it has a long-life design with tens of thousands of mechanical operation cycles, ensuring stable power supply.
This recloser controller offers a variety of optional relay protection logics including over‑current, negative‑sequence, directional, over‑/under‑voltage and earth‑fault protection, with support for ANSI/IEC curves and customizable functions.
Equipped with RS‑232/RS‑485 interfaces and multiple power communication protocols, it supports GPRS/GSM communication, allows pre‑programming of reclosure parameters, and provides electrical parameter measurement together with up to 10 000 SOE event and fault records.

The following information describes the curve timing for the curve and time dial settings made for the time‑overcurrent elements. The time‑overcurrent relay curves in conform to IEEE C37.112‑1996 IEEE Standard Inverse‑Time Characteristic Equations for Overcurrent Relays.

|
Rated maximum voltage |
15.6kV |
|
Rated maximum current |
1250A |
|
Rated frequency |
50Hz |
|
Rated short circuit breaking current |
12.5kA |
|
Rated peak value withstand current |
31.5kA |
|
Rated 1min power frequency withstand voltage(Single-phase Silicone rubber pole (unable the gas)) |
60kV |
|
Rated lightning impulse voltage(Single-phase Silicone rubber pole (unable the gas)) |
125kV |
|
Operation sequence |
C-0.5-CO-2-CO-5-CO(Magnetic actuator) |
|
Mechanical life |
n:30000(Magnetic actuator) |
|
Power supply and operating voltage |
110/220V (Customized) |
|
Ratio of current transformer |
400/1A (Customized) |
|
Number of voltage sensors(Single-phase Silicone rubber pole (unable the gas)) |
≤1 |
|
Opening time |
≤20ms(Magnetic actuator) |
|
Closing time |
≤30ms(Magnetic actuator) |
|
Minimum creepage distance |
31, level4(mm/kV) |
|
Minimum distance between phases |
360mm |
|
Potential transformer |
110/220V (Customized) |
|
Cable length |
6,8,12m (Customized) |
|
Cable clamp(Single-phase Silicone rubber pole (unable the gas)) |
2-hole NEMA |
|
Lightning arrester |
≤6 |
|
Mounting type |
Single / double column |
|
With optional relay protection & logics for user choice |
Instantaneous over-current protection Timing over-current protection Negative sequence over-current protection Directional over-current protection(⁽¹⁾) Over-voltage protection / Under voltage protection Programmable protection relay curves (total 10 nos ANSI/IEC curves) Cold load pickup protection TCC + Hot line tag Earth protection E/F SEF + Zone- Sequence Co-ordination More relay functions can be customized |
|
With optional communication protocols & I/O port for user choice |
RS-232 and RS-485 ports supporting DNP3.0 communication protocol support Modbus communication protocol is optional IEC 60870-501 communication protocol support IEC 60870-5-104 communication protocol support The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language |
|
With optional functions for use |
Rated currents, System phase current, Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency power (kWh), reactive power (kVarh), power factor |
|
With optional reclosing interval for user pre-program |
reclosing times setting support Dead time setting support |
|
With events recording function |
SOE 10000 operations record Fault record and normal operation record Note:mean should customized by manufacturer if needed |
|
Maximum temperature: |
+40°C |
|
Minimum temperature: |
-30°C |
|
Monthly average humidity |
95% |
|
Humidity: |
90% |
|
Above sea level: |
2500m or higher |
|
Ambient air Not apparently polluted by corrosive and flammable gas, vapor |
Sì. Oltre alla gamma standard da 2A a 16.000A, Rockwill fornisce unità configurate su misura per la misurazione e la protezione di correnti ultra-basse nell'intervallo da 0,1A a 2A.
Il richiusore automatico intelligente standard Rockwill offre un'elevata precisione con un ampio intervallo di misurazione (2A–16.000A). Assicurarsi semplicemente che la corrente normale rientri in questo intervallo standard in fase di selezione.
Mentre lo ZW32 è un interruttore automatico di base che richiede un controllore esterno, l'RCW è un richiusore automatico per smart grid completamente integrato, dotato di protezione integrata, sensori e comunicazione.
Inoltre, l'RCW è strettamente conforme agli standard IEC 62271-111 e ANSI C37.60, caratterizzato da un isolamento di alta qualità su misura per i progetti internazionali di automazione della distribuzione.
Sì, Rockwill offre programmi OEM/ODM completi per il richiusore sottovuoto monofase RCW. Per mantenere i nostri elevati standard di qualità, collaboriamo esclusivamente con produttori e distributori regionali che possiedono solide competenze ingegneristiche e capacità di assistenza locale.
Il nostro obiettivo è costruire alleanze strategiche che offrano non solo hardware di prima qualità, ma anche un eccezionale supporto tecnico locale per la modernizzazione della rete intelligente.
I guasti alla rete di distribuzione si verificano occasionalmente con lunghi cicli di accumulo dei dati. I richiusori sono installati su pali aerei e possono incontrare guasti solo una volta ogni svariati mesi o anni.
Le unità di controllo convenzionali possono memorizzare solo centinaia di record e i vecchi dati verranno sovrascritti dai nuovi eventi. L'archiviazione SOE ad alta capacità da 10.000 punti impedisce la perdita dei primi record di guasto, preservando registri degli eventi completi e ordinati in sequenza temporale per le analisi successive.