占位边距

Access Rockwill’s comprehensive library of technical resources — including white papers, product manuals, installation guides, and certification documents. Download expert insights and operational support for power systems, EV charging, and smart grid solutions.

Access Rockwill’s comprehensive library of technical resources — including white papers, product manuals, installation guides, and certification documents. Download expert insights and operational support for power systems, EV charging, and smart grid solutions.

Explore Rockwill’s centralized resource hub for critical technical documentation and industry knowledge. We provide downloadable white papers on smart grid trends, fault detection technologies, and energy transition strategies — ideal for engineers, project planners, and utility operators.
SEC SPECIFICATION FOR SURGE ARRESTERS FOR 13.8KV AND 33KV MEDIUM-VOLTAGE OVERHEAD DISTRIBUTION NETWORK
Restricted.
SEC SPECIFICATION FOR SURGE ARRESTERS FOR 13.8KV AND 33KV MEDIUM-VOLTAGE OVERHEAD DISTRIBUTION NETWORK
Others English
PDF
This PDF is SEC utility technical specification for 13.8kV‑33kV overhead‑network surge arresters, intended for EPC contractors, bidders and design‑institutes for tender response, gap‑analysis and technical evaluation. This gapless metal‑oxide surge arrester complies with IEC 60099‑4 and SEC local project specifications. It covers two classes: heavy‑duty with 20kA short‑circuit rating and riser‑pole type with 31.5kA short‑circuit rating, 10kA nominal discharge‑current, 60Hz system, defined MCOV a
SEC SPECIFICATIONS FOR SMART MV AUTO-RECLOSER
Restricted.
SEC SPECIFICATIONS FOR SMART MV AUTO-RECLOSER
Others English
PDF
This PDF is Saudi Electricity Company utility‑grade technical specification for pole‑mounted smart medium‑voltage auto‑recloser, for EPC contractors, bidders and design‑institutes for tender response, technical gap‑analysis and pre‑award evaluation. The pole‑mounted auto‑recloser complies with IEC 62271‑100, IEEE C37.60, IEC 60870‑5, IEC 61850 and SEC local project requirements.Key ratings cover 13.8‑36 kV, 560A continuous current, 12kA 3‑second short‑time withstand & breaking capacity, adju
RSP specification for mv smart line sectionalizer
Restricted.
RSP specification for mv smart line sectionalizer
Others English
PDF
This PDF is SEC’s utility‑grade technical specification for pole‑mounted smart line sectionalizer, for EPCs, bidders and design institutes for tender submission, gap analysis and pre‑award review. It follows IEC 62271‑103, ANSI C37.63, IEC 60870‑5, IEC 61850 and SEC requirements. Ratings: 13.8‑36 kV, 400A continuous current, 10kA‑3s short‑time withstand; adjustable 16‑640A phase‑fault, 3.5‑320A earth‑fault, 1‑3 configurable trip counts. Equipped with vacuum/SF6 interruption, sealed stainless‑ste
EEHC Distribution materials specification for 24kv ring mian units
Restricted.
EEHC Distribution materials specification for 24kv ring mian units
Others English
PDF
This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of  Ring Main Units  on EEHC in 24kV HV Switchgear.ROCKWILL 24kV Ring Main Unit is engineered to fully comply with EEHC Distribution Materials Specification EDMS 02-202-1 for Egyptian medium voltage distribution network. It covers both gas-insulated (GIS) and air-insulated (AIS) type, rated voltage 24kV, rated current up to 630A
Specification for 33kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Restricted.
Specification for 33kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Others English
PDF
This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of automatic reclosing on 33kV columns in Kenya Power and Lighting Company Limited (KPLC) 33kV 50Hz medium voltage distribution network.ROCKWILL 33kV Vacuum Automatic Recloser is pole-mounted outdoor equipment fully engineered to satisfy KPLC specification for Kenya’s 33kV overhead distribution network. Nominal system voltage 33k
Electric Du Cambodge Technical Specification for 22 kV Ring Main Units
Restricted.
Electric Du Cambodge Technical Specification for 22 kV Ring Main Units
Others English
PDF
This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of  Ring Main Units  on Electric Du Cambodge in 22kV 50Hz HV Switchgear.ROCKWILL 22kV Ring Main Unit is engineered to fully comply with EDC-DTS-MV003 specification for Cambodia’s 22kV underground distribution network. Rated equipment voltage 24kV, nominal system voltage 22kV, rated continuous current 630A, rated short-time withst
Specification for 11kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Restricted.
Specification for 11kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Others English
PDF
This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of automatic reclosing on 11kV columns in Kenya Power and Lighting Company Limited (KPLC) 11kV 50Hz medium voltage distribution network.ROCKWILL 11kV Vacuum Automatic Recloser is pole-mounted outdoor apparatus fully engineered to comply with KPLC specification for Kenya’s 11kV overhead distribution network. Nominal system voltage
BREB 33kV Automatic Circuit Reclose Specification Submission Sheet
Restricted.
BREB 33kV Automatic Circuit Reclose Specification Submission Sheet
Others English
PDF
This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of automatic reclosing on 33kV columns in Bangladesh Rural Electrification Board (BREB) 33kV 50Hz medium voltage distribution network.ROCKWILL 33kV Automatic Circuit Recloser is three-phase pole-mounted vacuum recloser designed to satisfy BREB 33kV Automatic Circuit Reclose Specification Submission Sheet for Bangladesh rural over
BREB 11kV Automatic Circuit Reclose Specification Submission Sheet
Restricted.
BREB 11kV Automatic Circuit Reclose Specification Submission Sheet
Others English
PDF
This document applies to the technical requirements for the design, testing, supply, installation, and related supporting equipment (sensors, controllers, cables, etc.) of automatic reclosing on 11kV columns in Bangladesh Rural Electrification Board (BREB) 11kV 50Hz medium voltage distribution network.ROCKWILL 11kV Automatic Circuit Recloser is three-phase pole-mounted vacuum recloser designed to comply with BREB 11kV Automatic Circuit Reclose Specification Submission Sheet for Bangladesh rural
33kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Restricted.
33kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Others English
PDF
BREB Class III 33KV three-phase solid dielectric automatic circuit recloser, compliant with ANSI/IEEE standards, suits tropical climates. Features vacuum interruption, adjustable operation, 3-year warranty, for REB overhead distribution & substations.ROCKWILL Class III 33kV Automatic Circuit Recloser is three-phase pole-mounted vacuum recloser designed in compliance with IEEE C37.60 Class III and IEC 62271-111 for Bangladesh 33kV overhead distribution feeders. Nominal system voltage 33kV, ra
11kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Restricted.
11kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Others English
PDF
BREB Class III 11KV three-phase solid dielectric automatic circuit recloser, compliant with ANSI/IEEE standards, suits tropical climates. Features vacuum interruption, adjustable operation, 3-year warranty, for REB overhead distribution & substations.ROCKWILL Class III 11kV Automatic Circuit Recloser is three-phase pole-mounted vacuum recloser designed in compliance with IEEE C37.60 Class III and IEC 62271-111 for Bangladesh 11kV overhead distribution feeders. Nominal system voltage 11kV, ra
15kV Switching Station requirements in Ethiopia Tender Documents
Restricted.
15kV Switching Station requirements in Ethiopia Tender Documents
Others English
PDF
This is African Development Bank‑financed complete bidding document issued by Ethiopian Electric Utility, targeted for EPC contractors, tenderers and design institutes for tender preparation and bid response.It complies with current IEC series, ISO and local Ethiopian project requirements, covering full bidding procedures, employer’s technical requirements, test & inspection rules, qualification criteria, contract general & particular conditions, environmental‑social safeguard clauses, d
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO