占位边距

Access Rockwill’s comprehensive library of technical resources — including white papers, product manuals, installation guides, and certification documents. Download expert insights and operational support for power systems, EV charging, and smart grid solutions.

Access Rockwill’s comprehensive library of technical resources — including white papers, product manuals, installation guides, and certification documents. Download expert insights and operational support for power systems, EV charging, and smart grid solutions.

Explore Rockwill’s centralized resource hub for critical technical documentation and industry knowledge. We provide downloadable white papers on smart grid trends, fault detection technologies, and energy transition strategies — ideal for engineers, project planners, and utility operators.
RCW-15KV Outdoor Automatic Recloser
Public.
RCW-15KV Outdoor Automatic Recloser
Technical Data English
PDF
This OEM technical specification document is compiled in accordance with prevailing IEC 62271 series and relevant international standards for high‑voltage switchgear and control‑gear. The document contains complete breaker parameter tables, controller performance indexes, EMC requirements, protection function list and supported communication protocols. It integrates vacuum interruption unit, intelligent protection‑control unit and multi‑media communication capability, supports hot‑stick manual o
Outdoor High-Voltage Vacuum Load Break Switch 35kV
Public.
Outdoor High-Voltage Vacuum Load Break Switch 35kV
Technical Data English
PDF
This PDF product flyer serves for tender comparison, overhead‑distribution‑project selection and pre‑sales technical evaluation. The equipment complies with IEC 62271‑1 general specifications for high‑voltage switchgear and IEC 62271‑103 for AC load‑break switches up to 52 kV. Adopting three‑phase vacuum‑interrupter interruption medium, it delivers stable performance for both 50 Hz and 60 Hz power grids. Equipped with modular spring operating mechanism supporting convenient manual operation, it
12kV/17.5kV/24kV Indoor MV Vacuum Circuit-Breaker
Restricted.
12kV/17.5kV/24kV Indoor MV Vacuum Circuit-Breaker
Technical Data English
PDF
VSC is lateral fixed‑type indoor vacuum circuit‑breaker with simple‑reliable high‑endurance spring mechanism, optional counter & 8NO‑8NC auxiliary switch. Insulation medium, secondary wiring and ratings are optional with special dimension custom‑order available, complying with IEC 62271‑100 for MV circuit‑breakers.
33 kV On Load Automatic Voltage Regulator
Restricted.
33 kV On Load Automatic Voltage Regulator
Technical Data English
PDF
This oil‑immersed voltage regulator adopts ONAN cooling, on‑load tap‑changer with battery backup, Auto‑Local‑Manual operation mode and comprehensive alarm signal outputs. It complies with IEC 60076‑1/5/7/10/21, IEC 60137 and other standards, suitable for C5 high atmospheric corrosivity environment.
RPS 15/27kV SF6 Load break switch(LBS) technology specification
Restricted.
RPS 15/27kV SF6 Load break switch(LBS) technology specification
Technical Data English
PDF
This is OEM technical specification for outdoor overhead‑line load break switch, complying with prevailing IEC high‑voltage switchgear series standards. This document defines comprehensive switch‑body performance indexes, controller protection‑measurement functions, EMC requirements, supported communication protocols and network access modes, manual/remote operation logic, gas‑monitoring requirements, counter function, and scope of supporting mounting accessories. It specifies performance classe
RPS 38kV SF6 Load break switch(LBS) technology specification
Restricted.
RPS 38kV SF6 Load break switch(LBS) technology specification
Technical Data English
PDF
This is OEM technical specification for high‑voltage outdoor overhead‑line load break switch, complying with prevailing IEC high‑voltage switchgear series standards. This specification defines controller measurement‑protection capability, complete EMC immunity requirements, diverse communication protocols and wireless network access options, multi‑path operation logic, gas‑monitoring and counter requirements, and supporting mounting accessories. It clarifies backup‑battery working conditions, AN
38kV automatic recloser technology specification
Restricted.
38kV automatic recloser technology specification
Technical Data English
PDF
This is OEM technical specification for outdoor overhead‑feeder automatic recloser, complying with prevailing IEC high‑voltage switch‑gear series standards. This document defines controller protection‑measurement functions, comprehensive EMC immunity requirements, rich communication protocols including IEC 61850 and diverse wireless network access modes, multi‑mode local‑remote operation logic, trip‑counter and optional mechanical‑lock‑in function, and supporting mounting‑accessory scope. It spe
15kV automatic recloser technology specification
Public.
15kV automatic recloser technology specification
Technical Data English
PDF
This OEM technical specification complies with prevailing IEC high‑voltage switchgear standards. It covers controller protection & metering functions, full EMC immunity tests, multiple communication protocols including IEC 61850, local & remote operation logic, trip counter, optional mechanical lock, and full accessory scope. It defines backup battery working conditions, ANSI protection element mapping and supports custom tender‑oriented configuration. Contact us for compliance certifica
27kV automatic recloser technology specification
Public.
27kV automatic recloser technology specification
Technical Data English
PDF
This OEM technical parameter datasheet follows prevailing IEC high‑voltage switchgear standards. Widely used for overhead distribution networks, rural power grids and industrial feeder renovation projects. This document lists complete electrical & mechanical parameter tables, defines controller protection and metering functions, EMC performance, communication protocols including IEC 61850, operation logic, trip counter and optional mechanical lock. It covers backup battery requirements, ANSI
138kV Dead‑Tank Circuit Breaker Technical Specification | IEEE & ANSI Compliant
Restricted.
138kV Dead‑Tank Circuit Breaker Technical Specification | IEEE & ANSI Compliant
Technical Data English
PDF
This OEM technical parameter datasheet complies with current IEEE and ANSI high voltage circuit breaker standards, widely applied in power transmission substation new construction and capacity expansion renovation. This document contains complete electrical and mechanical parameter tables, defines insulation design, mechanical operation characteristics, protection & monitoring functions, communication interfaces and anti-corrosion treatment requirements. It specifies type test requirements,
138kV Dead-Tank Circuit Breaker Technical Specification | IEC Compliant
Restricted.
138kV Dead-Tank Circuit Breaker Technical Specification | IEC Compliant
Technical Data Chinese
PDF
This OEM technical parameter datasheet complies with current IEC standards for high‑voltage circuit breakers and is applicable to power transmission substation projects. The document contains complete electrical and mechanical parameter tables, and defines insulation design, mechanical operating characteristics, protection and monitoring functions, communication interfaces and anti‑corrosion requirements. It specifies type‑test requirements and key points for on‑site installation, and supports c
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO