| Brand | ROCKWILL |
| Series | RSS |
| Rated current | 630A |
| Rated peak withstand current | 50(63)kA |
| Rated short-circuit breaking current | 31kA |
| Mechanical life of load switchtimes | M2 10000 times |
This product integrates the R&D experience of air-insulated switchgear and gas-insulated switchgear, representing a major technological breakthrough in the medium-voltage field with high operational safety. As a core unit of the power distribution network, it adopts a vacuum interrupter for arc extinction. The high-voltage live parts are molded from solid insulating materials (epoxy resin), eliminating the need for a pressurized gas compartment and achieving full insulation, full sealing, and maintenance-free operation.
The product is equipped with an intelligent online monitoring system that monitors the status of key components inside the switchgear in real time, acquires status parameters, and automatically evaluates the possibility of faults, providing strong protection for the normal operation of the switchgear and the entire distribution line.
The voltage classes of some of these eco-friendly switchgears include 6kV- 69kV. and customization is available.
|
Item |
Unit |
Parameter |
|
Rated short-time withstand current |
kA/s |
20/4(25/4) |
|
Rated peak withstand current |
kA |
50(63) |
|
Load Switch Unit |
||
|
Rated current |
A |
630 |
|
Rated short-circuit making current |
kA |
50 |
|
Rated short-time withstand current |
kA/s |
20/4 |
|
Mechanical life of load switch |
times |
M2 10000 |
|
Mechanical life of three-position disconnector |
times |
M1 3000 |
|
Electrical life of load switch |
times |
E2 100 |
|
Circuit Breaker Unit |
||
|
Rated current |
A |
630 (1250) |
|
Rated short-circuit breaking current |
kA |
20(25) |
|
Rated short-circuit making current |
kA |
50(63) |
|
Rated short-time withstand current |
kA/s |
20/4(25/4) |
|
Mechanical life of circuit breaker |
times |
M2 10000 |
|
Mechanical life of three-position disconnector |
times |
M1 3000 |
|
Electrical life of circuit breaker |
times |
E2 |
|
Rated operation sequence |
0 - 0.3s - CO - 180s - CO |
|
|
Load Switch-Fuse Combination Unit |
||
|
Rated current (maximum) |
A |
200 |
|
Rated short-circuit breaking current |
kA |
31.5 |
|
Rated short-circuit making current |
kA |
80 |
|
Rated transfer current |
A |
3150 |
Note: Customized designs are available for special environmental conditions.
This product is a green and eco-friendly solid insulated switchgear that has undergone type testing and is suitable for various distribution systems, including extremely harsh environmental conditions:
Substations:
Industrial Field:
Yes. We can dispatch experienced engineers for on-site installation guidance, commissioning, and operator training. Remote technical support is also available 24/7.
It monitors the status of key components inside the switchgear in real time, including temperature, humidity, partial discharge, and switch position. It automatically evaluates the possibility of faults and provides early warnings to ensure safe operation of the distribution line.
Yes. High-voltage live parts are fully molded in epoxy resin, achieving full insulation, full sealing, and no pressurized gas compartment, ensuring lifelong maintenance-free operation. The design life is typically over 30 years.