Reliable SF6 Insulated Switchgear/RMU for power distribution system-24kV

  • Reliable SF6 Insulated Switchgear/RMU for power distribution system-24kV

Key attributes

Brand ROCKWILL
Model NO. Reliable SF6 Insulated Switchgear/RMU for power distribution system-24kV
Rated voltage 24kV
Rated frequency 50/60Hz
Series RMR

Description

RMR-24 SF6 gas insulated ring main unit has passed type tests at a national electrical testing center. It is widely used in 24kV/12kV power distribution systems, making it a preferred switchgear solution for urban and rural networks.

The cabinet adopts a modular unit design, configurable for different applications through a combination of fixed and expandable units. This modular approach, supporting both full and half modules, offers exceptional flexibility. The switchgear complies with GB standards and has a design life exceeding 30 years under indoor conditions (20℃).

Product Showcase Video

Features

  • High-efficiency insulation performance: SF₆ gas with high insulation strength for stable 24kV operation

  • Compact design: space-saving for urban and industrial installations

  • High reliability: sealed structure, dustproof/moisture-proof/corrosion-resistant

  • Safety: complete interlocking protection, SF₆ leakage detection

  • Flexible adaptability: supports multiple wiring schemes

  • Environmental and economical: SF₆ recyclable, long service life

Parameters 

Rated voltage 24 kV
Rated frequency 50/60 Hz
Rated current 630 A
Rated short-time withstand current 20 kA / 3s
Rated peak withstand current 50 kA
Power frequency withstand voltage (1 min) 50 kV (phase-to-earth/between phases)
60 kV (across isolating distance)
Lightning impulse withstand voltage (peak) 125 kV (phase-to-earth/between phases)
145 kV (across isolating distance)
Degree of protection IP67

Environmental Conditions

  • Suitable Altitude: ≤ 2000m Suitable

  • Temperature: -40℃ ~ +55℃

  • Humidity: Daily mean ≤ 95%, monthly mean ≤ 90%

  • Gradation of Earthquake Damage: ≤ Level 8

Solutions for RMU

  • Rockwill's SF6 Circuit Breaker Solution for 33kV Substations in Nigeria
    Project BackgroundNigeria’s tropical climate, characterized by year-round high temperatures (annual average of 35°C) and humidity (≥80%), poses significant challenges to the sealing integrity, insulation performance, and gas management of electrical equipment. Rockwill was contracted to upgrade a 33kV substation, deploying its proprietary HV-type SF6 circuit breaker to address critical issues: Sealing Failure Risks: Accelerated aging of seals due to heat and water ingres

Documentation Resource Library RMU

Metropolitan Electricity Authority Technical Specification NO.108 for 12/24kV Ring Main Units
Restricted.
Metropolitan Electricity Authority Technical Specification NO.108 for 12/24kV Ring Main Units
Technical Specifications
English
PDF
PDF
Bidding Document Supply, Test and Commissioning of MV Switching Stations (RMU) for Addis Ababa Distribution Network
Restricted.
Bidding Document Supply, Test and Commissioning of MV Switching Stations (RMU) for Addis Ababa Distribution Network
Technical Specifications
English
PDF
PDF
EEHC Distribution materials specification for 24kv ring mian units
Restricted.
EEHC Distribution materials specification for 24kv ring mian units
Others
English
PDF
PDF
Electric Du Cambodge Technical Specification for 22 kV Ring Main Units
Restricted.
Electric Du Cambodge Technical Specification for 22 kV Ring Main Units
Others
English
PDF
PDF
Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

FAQ for RMU

Does the RMR-24 support SF₆ gas leakage monitoring?

Yes. The RMR-24 is equipped with SF₆ gas leakage detection, combined with a fully sealed structure for real-time gas integrity monitoring and safe operation.

How does the modular design support flexible configuration?

The RMR-24 features a modular unit design, configurable through combinations of fixed and expandable units. It supports full and half modules, providing exceptional flexibility for on-site deployment.

What distribution systems is the RMR-24 suitable for?

The RMR-24 is widely used in 24kV/12kV distribution systems and is a preferred switchgear solution for urban and rural power networks.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
WhatsApp
WhatsApp
Chat
Chen/CEO