占位边距

Three-phase vacuum Smart recloser/Reclosure for overhead power network-27kV

  • Three-phase vacuum Smart recloser/Reclosure for overhead power network-27kV
  • Three-phase vacuum Smart recloser/Reclosure for overhead power network-27kV
  • Three-phase vacuum Smart recloser/Reclosure for overhead power network-27kV

Key attributes

Brand ROCKWILL
Series RCW
Rated voltage 27kV
Rated current 400A 630A 800A 1250A
Rated short-circuit breaking current 12.5kA 16kA 20kA 25kA
Power frequency withstand voltage 45kV/min
Rated lightning impulse voltage 125kV
Standard IEC 62271‑1 IEC 62271-111

Description

Description:

As a pioneering original equipment manufacturer (OEM) in China’s recloser industry, we have accumulated decades of R&D expertise, taken the lead in establishing the original industry standards, built a fully independent end-to-end production system, and delivered reliable product solutions for power grid construction.

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes  at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions ofcontrol, protection, measurement, communication, fault detection, on-linemonitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Automatic Fault Isolation: Accurately identifies and isolates permanent faults within milliseconds, reducing outage scope by over 85%.

  • Automatic Service Restoration: Restores power to non-faulted sections within 2 seconds via intelligent topology reconfiguration, ensuring continuous operation of critical loads.

  • Fault Detection and Protection: Employs high-frequency transient recording and AI diagnostics to accurately identify 32 types of fault characteristics, enabling adaptive protection.

  • Sectionalizing Protection: Supports four-level grading coordination and virtual segmentation with ±10ms timing accuracy, eliminating the need for additional physical switches.

  • High Reliability and Durability: Core components are validated for 100,000 mechanical operations, featuring wide-temperature operation (-40°C to 75°C) and IP68 protection rating.

  • Environmentally Friendly: Utilizes vacuum arc-extinguishing technology with zero SF6 gas usage,

Parameters:

The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.

Rated maximum voltage

15kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

12.5kA

Rated peak value withstand current

31.5kA

Rated 1min power frequency withstand voltage (Three-phase Silicone rubber pole (unable the gas))

45kV

Rated lightning impulse voltage (Three-phase Silicone rubber pole (unable the gas))

120kV

Operation sequence

C-0.5-CO-2-CO-5-CO (Magnetic actuator)

Mechanical life

n:30000 (Magnetic actuator)

Power supply and operating voltage

110/220V (Customized)

Ratio of current transformer

400/1A (Customized)

Number of voltage sensors (Three-phase Silicone rubber pole (unable the gas))

≤3

Opening time

≤30ms (Magnetic actuator)

Closing time

≤40ms (Magnetic actuator)

Minimum creepage distance

31, level4 (mm/kV)

Minimum distance between phases

360mm

Potential transformer

110/220V (Customized)

Cable length

6,8,12m (Customized)

Cable clamp (Three-phase Silicone rubber pole (unable the gas))

2-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection & logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(⁽¹⁾)

Over-voltage protection / Under voltage protection

Programmable protection relay curves (total 10 nos ANSI/IEC curves)

Cold load pickup protection TCC + Hot line tag

Earth protection E/F SEF + Zone- Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support

Modbus communication protocol is optional

IEC 60870-501 communication protocol support

IEC 60870-5-104 communication protocol support

The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language

With optional functions for use

Rated currents, System phase current,

Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency

power (kWh), reactive power (kVarh), power factor

With optional reclosing interval for user pre-program

reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note:mean should customized by manufacturer if needed

Environmental requirement:

Maximum temperature:

+40°C

Minimum temperature:

-30°C

Monthly average humidity

95%

Humidity:

90%

Above sea level:

2500m or higher

Ambient air Not apparently polluted by corrosive and flammable gas, vapor



Product show:

正方形最新环氧聚脂带手和.png

Solutions for Auto Circuit vacuum recloser

  • High-Load Intelligent Recloser Solution for Nigeria's Industrial Zones
    Reclosers: Powering Nigeria’s Industrial Resurgence with Smart Grid Resilience​Nigeria’s "re-industrialization" drive—spanning automotive manufacturing, mineral processing, and energy-intensive sectors—faces crippling grid constraints. Industrial zones grapple with three critical challenges:​Chronic Power Instability​Aging infrastructure triggers frequent faults (e.g., short circuits in Lagos factories, overloads in Delta State gas hubs). Traditional fuses and circuit bre

Reference Projects for Auto Circuit vacuum recloser

  • Successful Case of 170 Sets of 11kV Automatic Recloser Project in Kenya
    Against the backdrop of quality upgrading for Kenya’s urban and rural power grids, 11kV auto-reclosers deliver reliable performance to suit local climates and grid conditions. It enables rapid fault isolation and efficient operation and maintenance, forming a core safeguard for the upgrading of Kenya’s urban and rural distribution networks.01 Project Overview1.1 Project BackgroundIn May 2023, 170 sets of 11kV Automatic Reclosers (Model: RCW12M) were officially supplied and applied to

Documentation Resource Library Auto Circuit vacuum recloser

BREB 11kV Automatic Circuit Reclose Specification Submission Sheet
Restricted.
BREB 11kV Automatic Circuit Reclose Specification Submission Sheet
Others
English
Consulting
Consulting
11kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Restricted.
11kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Others
English
Consulting
Consulting
15 kV Pole Mount Auto Recloser Technical Specifications for Guyana Power & Light Incorporated (GPL)
Restricted.
15 kV Pole Mount Auto Recloser Technical Specifications for Guyana Power & Light Incorporated (GPL)
Others
English
Consulting
Consulting
15kV Switching Station requirements in Ethiopia
Restricted.
15kV Switching Station requirements in Ethiopia
Others
English
Consulting
Consulting
15kV/27kV/38kV outdoor auto break vacuum recloser brochure
Restricted.
15kV/27kV/38kV outdoor auto break vacuum recloser brochure
Brochure
English
Consulting
Consulting
10 to 38kV auto vacuum break recloser Catalog
Restricted.
10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
Consulting
Consulting
15kV automatic recloser technology specification
Restricted.
15kV automatic recloser technology specification
Technical Data
English
Consulting
Consulting

Certifications Auto Circuit vacuum recloser

FAQ for Auto Circuit vacuum recloser

Q: Does Rockwill offer a cost-effective alternative that is more budget-friendly than the standard RCW+ series?
A:

Yes. The RCWP, a cost-optimized option in the RCW+ series, features dual sensors, flagship controller, and 30,000 operations with permanent magnet three-phase linkage, while offering downgrade options (lock box removal, lockout removal, sensor/controller downgrade) so customers pay only for what they need.

Q: Does Rockwill really provide a 10-year quality warranty and free replacement?
A:

Yes. Rockwill stands behind the RCW series with one of the most comprehensive warranties in the recloser industry: a full 10-year warranty covering the complete recloser, including the vacuum interrupter, permanent magnet operating mechanism, and control electronics. Any failure resulting from material or manufacturing defects during the warranty period is eligible for free replacement. Our warranty terms are straightforward and transparent, with no hidden conditions or complex exclusions, giving you complete peace of mind.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO