6-35KV 33KV oil-immersed neutral grounding resistance to transformer (earthing transfoemer)
  • 6-35KV 33KV oil-immersed neutral grounding resistance to transformer (earthing transfoemer)
  • 6-35KV 33KV oil-immersed neutral grounding resistance to transformer (earthing transfoemer)
Key attributes
Brand ROCKWILL
Model NO. 6-35KV 33KV oil-immersed neutral grounding resistance to transformer (earthing transfoemer)
Rated voltage 33kV
Rated frequency 50/60Hz
Rated capacity 800kVA
Series JDS
Product descriptions from the supplier
Description

Product Introduction

Our 6-35kV (including 33kV) oil-immersed neutral grounding resistance transformers, also known as earthing transformers, are designed for medium-voltage grids. Using oil cooling technology, they safely dissipate heat. By creating a neutral point connection with a grounding resistance, these transformers quickly detect and limit ground faults. Ideal for enhancing grid reliability, they offer robust protection against electrical failures, ensuring stable power supply for industrial and commercial applications.

Operating Conditions

  • Altitude: ≤1,000 meters

Ambient Temperature:

  • Maximum ambient temperature: +40°C

  • Maximum daily average temperature: +30°C

  • Maximum annual average temperature: +20°C

  • Minimum outdoor temperature: -25°C

Performance Advantages

  • Energy-Efficient & Eco-Friendly: Low-loss, low-noise, and high-efficiency design reduces energy consumption and environmental impact.

  • Fully Sealed & Maintenance-Free: No oil storage tank required. Corrugated tank design automatically adjusts for oil volume changes, eliminating leakage risks.

  • Extended Lifespan: Sealed structure isolates oil from air, slowing degradation and insulation aging. Reduces maintenance costs and extends operational life.

Main technical specifications

The following table details the key technical specifications of the product, comprehensively covering electrical performance, mechanical characteristics, and dimensional parameters to provide a clear reference for technical selection and application scenarios.

 

FAQ
Q: What are the special design requirements for earthing/grounding transformers used on ships or offshore platforms?
A:

The characteristics of the marine environment such as salt spray, humidity, vibration, and limited space require earthing/grounding transformers to meet special design requirements: ① Insulation protection: Use salt spray and mold resistant insulation materials (such as salt spray resistant cast resin), and coat the winding surface with anti-corrosion coating; ② Structural design: Adopt a compact modular structure to adapt to the narrow space of ships/platforms; dry-type (oil-free) is preferred to avoid oil leakage polluting the marine environment; ③ Vibration resistance: Enhance the winding fixing and core clamping structure to meet the mechanical requirements of ship sway and vibration (vibration grade ≥ IEC 60076-5 Class 3); ④ Voltage and frequency: Need to adapt to ship-specific voltage (such as 6.6kV) and frequency (such as 60Hz), and the auxiliary winding needs to meet the power demand of the ship's power station (such as 440V/220V); ⑤ Cooling method: Adopt natural air cooling (KNAN) to avoid fan failure affecting operation and adapt to the closed cabin environment.

Q: What parameters need to be focused on checking when replacing an earthing/grounding transformer to ensure compatibility with the original system?
A:

Six core parameters must be checked one by one during replacement to avoid compatibility issues: ① System line voltage: Must be consistent with the original (for example, 110kV grade must be replaced for the original 110kV); ② Zero-sequence impedance: The deviation from the original value must be ≤ ±10% to ensure that the protection setting value does not need to be adjusted; ③ Short-time capacity and fault withstand time: Must not be lower than the original grade (for example, the original 30 seconds/5MVA, the new product must meet or be better than this index); ④ Winding structure: Must be consistent with the original type (for example, the original zigzag type cannot be replaced with the wye-delta type) to avoid changes in grounding performance; ⑤ Insulation and cooling method: Must adapt to the original installation scenario (for example, the original outdoor oil-immersed type cannot be replaced with the indoor dry-type); ⑥ Auxiliary winding specifications (if any): The voltage level and capacity must match the original (for example, the original 400V/200kVA, the new product must be consistent) to ensure the normal power supply of the auxiliary load of the substation.

Related Products
Related Solutions
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
To Boss
IEE Business
Source professional electrical partners, experts, and explore smart grid & energy solutions.