Outdoor MV Triple‑single Auto Recloser Source Manufacturer-15kV to 38kV

  • Outdoor MV Triple‑single Auto Recloser Source Manufacturer-15kV to 38kV

Key attributes

Brand ROCKWILL
Series RCW
Rated maximum voltage 15kV 27kV 38kV
Rated maximum current 400/630/800/1250A
Rated short circuit breaking current 12.5/16/20/25*kA
Rated peak value withstand current 31.5/40/50/63*kA
Mechanical life 30000

Description

The RCW series outdoor medium-voltage triple-single automatic circuit recloser is an intelligent protection and control device designed for 15kV~38kV power distribution lines, complying with IEC 62271 and ANSI standards.

Adopting vacuum interrupter, permanent magnetic actuator and integrated stainless steel tank, it integrates protection, measurement, communication, fault location and online monitoring. It can quickly isolate line faults and automatically restore power supply, significantly improving the reliability of distribution networks, suitable for overhead lines, distribution substations and new energy grid-connected applications.

Product Showcase Video

Controller

The controller is equipped with complete relay protection and programmable logic, supports various standard communication protocols and remote communication, accurately measures electrical parameters, flexibly configures reclosing settings, and provides large-capacity event recording. It supports customized expansion to fully meet the intelligent control requirements of distribution automation.

Outdoor MV Triple‑single Auto Recloser Controller

Core Advantages

  • With vacuum interrupter and permanent magnetic actuator, the switching operation is precise and stable, with mechanical life up to 30,000 operations, long maintenance-free period, suitable for long-term unattended outdoor operation.

  • It supports multiple operation modes including independent phase control and three-phase linkage, featuring single-phase tripping, single-phase reclosing and single-phase lockout, which can accurately handle single-phase grounding and phase-to-phase faults, greatly reducing power outages in non-fault areas.

  • It integrates a full set of protection logic such as overcurrent, instantaneous overcurrent, zero-sequence, directional, over-voltage and under-voltage protection, supporting 10 ANSI/IEC protection curves to flexibly adapt to various line protection schemes.

  • Standard with RS485, Modbus, DNP3.0, IEC 60870-5-101/104 protocols, supporting GPRS/GSM remote communication, it can be connected to distribution automation systems for remote monitoring, fault recording and event logging.

  • The whole unit adopts 304 stainless steel tank with IP54 protection, resistant to high and low temperatures, corrosion and vibration. It can operate stably for a long time in extreme environments from -45℃ to +85℃, adapting to plateaus, coastal areas, cold and hot climates.

  • Flexible installation including single-pole, double-pole mounting and substation installation, with standard interfaces and cable configuration for easy on-site wiring and commissioning, suitable for both renovation and new projects.

Technical Parameters

N Item Unit Data
1 Rated maximum voltage kV 15、27、38
2 Rated maximum current A 400/630/800/1250
3 Rated frequency Hz 50/60
4 Rated short circuit breaking current kA 12.5/16/20/25*
5 Rated peak value withstand current kA 31.5/40/50/63*
6 Rated 1min power frequency withstand voltage (Dry/Wet) kV 28/36 60 70
7 Rated lightning impulse voltage kV 95、125、170
8 Operation sequence s C‑0.5‑CO‑2‑CO‑5‑CO
9 Mechanical life n 30000
10 Power supply and operating voltage V 110/220, Customized
11 Ratio of current transformer A 400/1, Customized
12 Number of voltage sensors n ≤6
13 Opening time ms ≤40
14 Closing time ms ≤50
15 Minimum creepage distance mm/kV 31, Level 4
16 Minimum distance between phases mm 360、380、435
17 Potential transformer V 110/220, Customized
18 Cable length m 6, 8, 12, Customized
19 Cable clamp 4‑hole NEMA
20 Lightning arrester n ≤6
21 Mounting type Single / double column

External dimensions

Outdoor MV Triple‑single Auto Recloser Source Manufacturer-15kV to 38kV

Application & Performance

  • Practical Application: Widely used in urban and rural distribution networks, industrial parks, new energy stations, mines and infrastructure lines at home and abroad. It realizes millisecond-level fault handling for common faults such as lightning strikes, tree barriers and single-phase grounding, with high automatic reclosing success rate, significantly reducing power outage time and manual inspection costs.

  • Core Technical Strengths: No oxidation and no gas leakage with vacuum interrupter; no jamming and no spring fatigue with permanent magnetic actuator; triple-single independent control better matches actual distribution network fault characteristics; all-condition design adapts to harsh environments with long-term stable performance.

Service Environment Specification Table

Item Specification
Air Temperature Maximum temperature: +85℃

 

Minimum temperature: -45℃
Humidity Monthly average humidity: 99%

 

Daily average humidity: 100%
Installation Altitude Maximum installation altitude: 2500m or higher
Ambient Environment Requirements Ambient air shall not be significantly polluted by corrosive, flammable gases or vapors; no frequent violent vibration

For more product details, technical drawings and selection guides, please click the button below to download the full documentation!

Solutions for Auto Recloser

  • Indonesia's Smart Recloser System: Integrated Solution for Volcanic Ash and Coastal Salt Corrosion Mitigation
    Project BackgroundIndonesia is situated within the Pacific Ring of Fire, experiencing frequent natural disasters that pose multiple threats to its power system:Geographical Risks: Volcanic Ash: The country has 127 active volcanoes. Eruptions produce Volcanic Ash containing sulfides and dust, accelerating corrosion of electrical equipment and causing insulator flashovers. Coastal High Salt Fog & Corrosion: With an 81,000 km coastline, salt fog permeation leads to severe Coastal Salt Corrosion
  • High-Load Intelligent Recloser Solution for Nigeria's Industrial Zones
    Reclosers: Powering Nigeria’s Industrial Resurgence with Smart Grid ResilienceNigeria’s "re-industrialization" drive—spanning automotive manufacturing, mineral processing, and energy-intensive sectors—faces crippling grid constraints. Industrial zones grapple with three critical challenges: Chronic Power InstabilityAging infrastructure triggers frequent faults (e.g., short circuits in Lagos factories, overloads in Delta State gas hubs). Traditional fuses and circuit breakers respond sluggishly,
  • Philippines Vacuum Recloser — Typhoon Failure Analysis and Wind-Resistant Remote O&M Solution for 13.2kV/34.5kV Distribution Networks
    I. Core Challenges Facing the Philippine Distribution Network1.1 Frequent Typhoons — Mechanical Impact and Post-Disaster RestorationDimensionDataImpact on Distribution NetworkAverage annual typhoon landfalls20 (PAGASAdata)Lines endure continuous mechanical stress during the May-December typhoon seasonSuper typhoon maximum wind speed>250 km/h (e.g., 2024 Typhoon Gaemi)Broken conductors, collapsed poles, hardware fatigue fracturePost-typhoon area outage duration3-14 days (industry survey

Reference Projects for Auto Recloser

  • DTEK Grid Upgrade: Operation of Rockwill 10kV Smart Recloser in -40°C Extreme Cold Environment Ukraine Case Study
    As a benchmark for Chinese‑manufactured medium‑voltage distribution equipment going global, Rockwill established in‑depth cooperation with DTEK Kyiv Power Grid, Ukraine. Tailored outdoor vacuum recloser solutions were mass‑deployed to address existing weaknesses in local 10 kV distribution networks, comprehensively improving regional power supply reliability and automation to build a flagship distribution grid modernization project in Kyiv.01 Project Background: Core Pain Points of DTEK Kyiv Dis
  • Rockwill Ukraine 186 Units 12kV Outdoor Vacuum Recloser Project Success Case
    In response to the operational characteristics of Ukraine’s local power grid and targeting harsh high-latitude outdoor working conditions, we rely on core technologies of intelligent reclosing and self-healing to precisely adapt to the complex grid environment with frequent thunderstorms and drastic diurnal temperature variations, steadily promoting the automatic and intelligent upgrade of regional rural power grids and suburban distribution networks.01 Project Overview1.1 Project BackgroundIn 2
  • Successful Case of 170 Sets of 11kV Automatic Recloser Project in Kenya
    Against the backdrop of quality upgrading for Kenya’s urban and rural power grids, 11kV auto-reclosers deliver reliable performance to suit local climates and grid conditions. It enables rapid fault isolation and efficient operation and maintenance, forming a core safeguard for the upgrading of Kenya’s urban and rural distribution networks.01 Project Overview1.1 Project BackgroundIn May 2023, 170 sets of 11kV Automatic Reclosers (Model: RCW12M) were officially supplied and applied to the medium-

Documentation Resource Library Auto Recloser

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English
RCW MV Triple-single Recloser catalog
Restricted.
RCW MV Triple-single Recloser catalog
Catalogue
English
PDF
PDF
RCW MV Triple-single recloser Brochure
Public.
RCW MV Triple-single recloser Brochure
Brochure
English

FAQ for Auto Recloser

Where is RCW MV Triple-single Recloser normally installed?

It is pole-mounted, widely applied on overhead MV distribution lines and smart grid distribution automation projects.

What is the biggest advantage of RCW MV Triple-single Recloser compared with common three-phase ganged recloser?

It supports independent phase trip. Single-phase fault will not cut off all three phases, reduce outage scope.

What standards does RCW MV Triple-single Recloser comply with?

Mainly IEC 62271-111, ANSI/IEEE C37.60 and IEC 62271-1.

What is RCW MV Triple-single Recloser?

It is outdoor pole-mounted vacuum recloser with three independent single-phase poles, can trip and reclose per phase individually for overhead distribution network.

What are the key differences between Rockwill's RCW series recloser and a ZW32-type vacuum circuit breaker?

The ZW32-type VCB is a basic circuit breaker or demarcation switch without built-in auto-reclosing logic, whereas the RCW series is specifically engineered as a full-function recloser with integrated protection, sensors, and communication for smart grid applications.

Unlike the ZW32, which requires an external controller for automation, the RCW series complies with IEC 62271-111 and ANSI C37.60, and is supported by complete type test reports.With silicone rubber or epoxy insulation offering superior aging resistance and low water absorption, the RCW series is the professional choice for international distribution automation projects.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO