Primary Air Insulated Switchgear

  • Primary Air Insulated Switchgear
  • Primary Air Insulated Switchgear
  • Primary Air Insulated Switchgear
  • Primary Air Insulated Switchgear
  • Primary Air Insulated Switchgear

Key attributes

Brand ROCKWILL
Series RMR,REC

Description

Medium-voltage metal-enclosed switchgear insulated by conditioned air, built for primary distribution networks. No SF6, no fluorinated gas, with sealed vacuum circuit breakers for clean, dependable protection of incoming and feeder circuits.

12–24kV              Primary MV class
630–1250A          Rated current
20kA/3s               Short-time withstand
Air                        SF6-free insulation

Primary Air Insulated Switchgear

What is primary air insulated switchgear?

Metal-enclosed MV switchgear where the high-voltage compartment is insulated by conditioned air rather than SF6, engineered for primary distribution — the upstream part of the network feeding secondary rings.

Primary air insulated switchgear uses conditioned air for phase-to-earth and phase-to-phase insulation, while a sealed vacuum circuit breaker handles current interruption. The panels are built for the higher reliability demands of primary networks — incomers, feeders, metering and bus-tie — and are type-tested to IEC 62271-200. With no SF6 sealed in, the switchgear has zero global-warming potential and no fluorinated-gas compliance burden.

Air insulation

Conditioned air provides clean, breathable, non-toxic insulation with zero GWP.

Vacuum breaker

Sealed vacuum circuit breakers handle load, fault and transformer currents independently of the gas.

Primary-grade ratings

Type-tested withstand levels for the reliability demands of primary distribution networks.

Primary Air Insulated Switchgear

Advantages for primary networks

SF6-free

No fluorinated gas — zero GWP and no F-gas reporting or recovery at end of life.

Safe on site

Air does not displace oxygen; no asphyxiation risk in switchrooms and cable areas.

Low maintenance

No gas-density top-ups; sealed vacuum parts and condition monitoring keep service simple.

Long service life

Sealed construction and vacuum breakers designed for decades of primary-network duty.

Recyclable

Steel enclosure and copper busbar recycle as standard materials at end of life.

OEM / ODM

Panels built to your one-line diagram and brand, with IEC 62271 documentation for tenders.

Primary Air Insulated Switchgear

Typical specifications

Representative values; the certified datasheet is prepared on request — contact us.

Parameter Typical value
Rated voltage 12kV / 24kV (36kV on request)
Power frequency withstand 50kV (1 min)
Lightning impulse withstand 125kV
Rated frequency 50 / 60 Hz
Insulation medium Conditioned air — SF6-free, GWP 0
Breaking device Sealed vacuum circuit breaker
Rated normal current 630A / 1250A (up to 2000A on request)
Rated short-time withstand 20kA / 3s (25kA on request)
Panel types Incomer, feeder, metering, bus-tie, transformer protection
Standard IEC 62271-1, IEC 62271-200

Solutions for Primary Air Insulated Switchgear

  • Rockwill Medium-Voltage SF6-Free Gas-Insulated Switchgear Series – From RMR to REC and RAR
    Within Rockwill's SF6-free product portfolio, the RMR, REC, and RAR series all adopt gas-insulated, hermetically sealed structures that fully enclose high-voltage live parts in stainless steel tanks, ensuring complete sealing and maintenance-free operation. The three series share a similar modular design philosophy, but differ significantly in insulation medium, technical positioning, voltage coverage, and application scenarios.Core DifferencesIn terms of insulation medium and environmental char
  • Optimization Design Scheme for the 12kV Air-Insulated Ring Main Unit Isolating Gap to Reduce Breakdown Discharge Probability
    With the rapid development of the power industry, the ecological concept of low-carbon, energy-saving, and environmental protection has been deeply integrated into the design and manufacturing of power supply and distribution electrical products. The Ring Main Unit (RMU) is a key electrical device in distribution networks. Safety, environmental protection, operational reliability, energy efficiency, and economy are inevitable trends in its development. Traditional RMUs are primarily represented

Reference Projects for Primary Air Insulated Switchgear

  • Rockwill RGIS Case Study and Gas Insulated Switchgear Project in Ghana
    Focusing on the demand for improved distribution network reliability in Ghana, 11kV R-GIS gas-insulated switchgear is adopted. Integrating advantages of compact design, weather-resistant protection and intelligent management, it adapts to limited installation space and complex tropical local environments. It supports the upgrading of regional power distribution infrastructure and realizes safe, stable, maintenance-free and efficient operation.01 Project Overview1.1 Project BackgroundGhana, as a

Documentation Resource Library Primary Air Insulated Switchgear

RGIS type C-GIS switchgear
Restricted.
RGIS type C-GIS switchgear
Catalogue
English
PDF
PDF
KYN28 Metal Clad Switchgear-7.2/12/15/24
Restricted.
KYN28 Metal Clad Switchgear-7.2/12/15/24
Catalogue
English
PDF
PDF
Technical Specification for Outdoor 33kV Switchgear
Public.
Technical Specification for Outdoor 33kV Switchgear
Technical Specifications
English
ZHW-145-HGIS HV Gas Insulated Switchgear
Restricted.
ZHW-145-HGIS HV Gas Insulated Switchgear
Catalogue
English
PDF
PDF
ZF HV Gas-Insulated Switchgear (GIS)
Restricted.
ZF HV Gas-Insulated Switchgear (GIS)
Catalogue
English
PDF
PDF

Certifications Primary Air Insulated Switchgear

FAQ for Primary Air Insulated Switchgear

Can it be built under our brand?

Yes. We manufacture primary air insulated switchgear under OEM/ODM with your nameplate, manuals and documentation.

Is it really SF6-free?

Yes. No SF6 or fluorinated gas is sealed in the panels; the global warming potential is zero.

Is air insulation reliable for primary networks?

Yes. When dimensioned and type-tested to the IEC 62271-200 withstand levels, conditioned air provides reliable insulation with sealed vacuum interruption.

What does "primary air insulated switchgear" mean?

It is MV metal-enclosed switchgear insulated by conditioned air, built for primary distribution — the upstream network — using vacuum circuit breakers instead of SF6.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
WhatsApp
WhatsApp
Chat
Chen/CEO