占位边距

Reliable SF6 Load Break Switch for Power Grids 24kV

  • Reliable SF6 Load Break Switch for Power Grids 24kV

Key attributes

Brand ROCKWILL
Series RLS
Rated voltage 24kV
Rated current 630/800A
Lightning impulse withstand voltage 125/150kV
Rated frequency 50/60Hz

Description

This SF6 load break switch, an switchgear with the rated voltage of 12kV/24kV/36kV, adopted with SF6 gas as an arc-extinguishing and insulation medium, including the three contactors for switching-on and switching-off and to ground, and is characteistic in its small volume, its convenient for installation and operation and its the great adaptability with surroundings.

The SF6 load break switch and RLS-24D of SF6 load switch plus fuse combination can function to protect and control the electric equipments for power supply and transformer substations especially being suitable for ring net cabinet, cable branch cabinet and distribution switching substation.
The SF6 load break switch and RLS-24D load switch plus fuse combination 

SF6 Load Break Switch Finished Product Showcase Video

Key Features

  • Hermetic epoxy gas tank, stable SF6 insulation, low leakage risk
  • Split external spring mechanism, visible 5-proof interlock, easy maintenance
  • Tall upward bushings, ample space for large cable wiring
  • Integrated 3-position (close/open/earth) design, reliable breaking capacity
  • Standard size compatible with domestic RMUs, direct FLN36 replacement
  • Long mechanical service life, stable performance for grid renovation
  • Wide temperature & altitude adaptability for indoor cabinet installation

Technical data

Unit
Parameter
 
Rated voltage
kV
24
Rated frequency
Hz
50/60
Rated current
A
630/800
wet
1min Power frequency  withstand voltage
dry
 
kV
50
 
60
Lightning impulse withstand voltage
kV
125/150
Rated short circuit breaking current (peak)
kA
Acc to CB & Fuse
Rated activeload and close circuit breaking current
A
630
Rated transferring current
A
1200
Rated short circuit making current (peak)
kA
40
Rated cable(line) charging breaking current
A
50 and 10
Cable charge breaking current in earthing fault
A
20
Rated withstand current (peak)
kA
40
Short time withstand current (2s)
kA
25
Mechanism life
times
2000

Dimension Drawing

SF6 Load Break Switch Dimension Drawing

Load Break Switch Assembly

SF6 Load Break Switch Assembly

Service environment

  • Air temperature:Maximum temperature: +40℃; Minimum temperature:-5℃
  • Humidity:Monthly average humidity 95%; Daily average humidity 90%.
  • Altitude above sea level:Maximum installation altitude: 2500m
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  • No frequent violent shake

Note: For short circuit breaking and peak current isbased on Fuseplus combination.

Application Scenarios

  • Ring main unit (RMU) installations
  • Cable distribution networks
  • Compact substations
  • Industrial power distribution
  • Renewable energy integration

Solutions for Load Break Switch

  • Tanzania 33kV SF6 Load Break Switch Seal Failure Solution: EPDM Material Upgrade and IEC 62271 Repair Guide
    1.What Extreme Challenges Does the Tanzania 33kV LBS Seal System Face?This report provides in-depth technical countermeasures for the high-frequency failure ofSF6 Load Break Switch (LBS) seal systemsin Tanzania's 33kV distribution network. Based on field data from Dar es Salaam (coastal) and Dodoma (semi-arid), the primary failure drivers areaccelerated O-ring degradation and electrochemical corrosion. According to our team's operational statistics in East Africa from 2019–2025, leaks at t

Reference Projects for Load Break Switch

  • 84 Units 33kV Outdoor SF6 Load Break Switches for Tanzania White City Power Project
    Rockwill has successfully delivered 84 units of 33kV outdoor SF6 load break disconnectors. The equipment has been officially commissioned and connected to the grid for operation in the White City Power Project of Tanzania REA Phase II, empowering the upgrading and improvement of rural power grids in Tanzania.01 General Overview: Tanzania White City 33 kV Grid Upgrade Project1.1 Project BackgroundThe Phase II project (REA II) of the Tanzania Rural Energy Agency (REA) is one of the largest rural e
  • Rockwill Strengthens Partnership in Indonesia with Bulk Delivery of RLS SF6 Load Break Switches
    Project SummaryIn July 2022, Rockwill successfully completed a significant bulk shipment of RLS SF6 Load Break Switches to the Indonesian market. This large-scale delivery underscores the growing demand for Rockwill's high-performance electrical components in Southeast Asia and marks another milestone in our long-standing and trusted partnership with local clients.Solution at a GlanceThe RLS SF6 Load Break Switches supplied are designed for reliable circuit isolation and protection in medium-vol

Documentation Resource Library Load Break Switch

RPS Pole-Mounted SF6 Load Break Switch(LBS)
Restricted.
RPS Pole-Mounted SF6 Load Break Switch(LBS)
Catalogue
English
PDF
PDF
Wear-Resistant 15kV SF6 Load Break Switch
Public.
Wear-Resistant 15kV SF6 Load Break Switch
Brochure
English
Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English
RLS type Indoor SF6 Load Break Switch
Restricted.
RLS type Indoor SF6 Load Break Switch
Catalogue
English
PDF
PDF

Certifications Load Break Switch

FAQ for Load Break Switch

Are you the manufacturer of this SF6 load break switch and RLS-24D? Can you do OEM/ODM?

Yes, we are a China Manufacturer. OEM/ODM is available for bushings, parameters, marking and custom requirements.

Can this SF6 load break switch directly replace FLN36?

Yes, standard dimension design, compatible with common RMUs for direct FLN36 replacement.

What is the limitation for short-circuit current of RLS-24D?

Its short-circuit breaking and peak current capacity depends on the matched fuse.

What is the advantage of split external spring mechanism for this SF6 load break switch?

This SF6 load break switch adopts split external spring mechanism with visible 5-proof interlock, convenient inspection and simpler on-site maintenance.

What is the advantage of tall upward bushings for this SF6 load break switch?

The tall upward bushings of this SF6 load break switch reserve sufficient space for large-diameter cable wiring.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO