Three-Phase Dry Type Zigzag Earthing Transformer Manufacturer-35 kV

  • Three-Phase Dry Type Zigzag Earthing Transformer Manufacturer-35 kV

Key attributes

Brand ROCKWILL
Series DKSC
Rated voltage 35 kV
Connection group Z (zigzag) / ZNyn11
Rated capacity range 100 – 5,500 kVA
Rated frequency 50 / 60 Hz

Description

Rockwill three-phase cast resin dry-type Z-type earthing transformers are engineered to create a reliable artificial neutral point for medium-voltage power systems. Utilizing advanced vacuum casting technology with high-quality epoxy resin, these Zigzag Earthing Transformers provide stable neutral grounding for ungrounded or delta-connected systems, specifically optimized for 35 kV applications.
Designed for safety and durability, they are maintenance-free, flame-retardant, and resistant to harsh environmental conditions, making them ideal for indoor substations and enclosed outdoor installations. As a leading Dry-type Earthing Transformer Manufacturer, Rockwill ensures full compliance with IEC standards, offering robust solutions for industrial facilities, renewable energy plants, and critical infrastructure requiring high reliability.

Key Features

  • Medium-Voltage Neutral Grounding :Provides an artificial neutral point for ungrounded or delta-connected systems at 35 kV, enabling connection of arc suppression coils or neutral grounding resistors.
  • Optimized Z-Type Winding :Zigzag winding configuration delivers low zero-sequence impedance, ensuring efficient fault current path and sensitive relay protection.
  • Cast Resin Dry-Type Construction :Epoxy resin vacuum casting with glass fiber reinforcement provides excellent insulation, moisture resistance, and flame-retardant performance. Maintenance-free throughout service life.
  • High Insulation Class :Class F insulation system rated for reliable operation in demanding environments.
  • Customizable Configuration :Available with or without secondary auxiliary winding; optional enclosure for outdoor installation.

Why Dry-Type for 35kV Grounding?

Consideration Oil-Immersed Solution Rockwill Cast Resin Solution
Fire risk in indoor or underground substations Requires oil containment / bund walls Flame-retardant epoxy — self-extinguishing
Maintenance during service life Oil sampling, level monitoring, gasket checks Maintenance-free cast winding
Environmental spills Oil leak = soil/groundwater contamination Zero liquid inventory
Space footprint Oil conservator + wider clearance Compact resin body, suited for cabinets
Installation environment Primarily outdoor Ideal for indoor, underground, or enclosed outdoor

 Product Showcase Video

Technical Parameters

Parameter Value
Rated voltage 35 kV
Rated frequency 50 / 60 Hz
Number of phases Three
Connection group Z (zigzag) / ZNyn11
Rated capacity range 100 – 5,500 kVA
Rated short-time duration 10 s / 30 s / 60 s (customizable)
Zero-sequence impedance (Zo) Per project specification
Insulation class F (IEC 60076-11)
Cooling method AN (air natural) / AF (air forced)
Auxiliary winding Optional (0.4 kV)
Ambient temperature –25 °C to +40 °C
Installation Indoor or outdoor (with enclosure)

Note:We support flexible customization for multi-voltage levels and specific technical parameters to match diverse project requirements. As a specialized manufacturer, we provide tailored solutions for rated capacity, impedance, and cooling methods to ensure optimal system compatibility.

Insulation Level

System Voltage Um (kV) PF (kV) LI (kV)
35 kV 40.5 95 200

Environmental Conditions

Max ambient air temperature +40°C
Max 24h average ambient air temperature +35°C
Min ambient air temperature -25°C
Altitude ≤ 1000 m
Max relative humidity (24h average) ≤ 95%
Max relative humidity (1 month average) ≤ 90%
Max water vapor pressure (24h average) 2.2 kPa
Max water vapor pressure (1 month average) 1.8 kPa
Solar radiation ≤ 1000 W/m²
Pollution level II

Outline Drawing

Zigzag earthing transformer structure drawing showing coil connections.

Dimensional drawing of 3-phase cast resin zigzag grounding transformer.

Applications

  • Medium-voltage distribution network neutral grounding at 35 kV
  • Industrial power systems requiring a neutral grounding point
  • Renewable energy plants (wind and solar farms) with ungrounded sources
  • Indoor substations and commercial building power systems
  • Utility and mining power distribution networks

Start Your Project

Send your system voltage, neutral current and time rating, target zero-sequence impedance, cooling preference, and installation environment to our MV engineering team. You will receive a tailored datasheet, outline drawing, and commercial quotation for your 35 kV grounding project.

Solutions for Earthing Transformer Manufacturer

  • Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid Stability
    Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid StabilityZig-Zag transformers (also known as Z-connected grounding transformers) offer significant advantages in Southeast Asian power systems due to their unique design, which addresses tropical climates, grid structures, and development needs. Below is an analysis of their core benefits and application scenarios:I. Cost Efficiency & Space Optimization Low-Cost SolutionSimplified constructio
  • Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding Transformers
    Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding TransformersZ-type grounding transformers are critical for stabilizing ungrounded or delta-connected power systems by providing a low-impedance path for zero-sequence currents during faults. Integrating intelligent maintenance and sustainability practices enhances their reliability while minimizing environmental impact. Below is a structured analysis of advanced solutions:I. Intelligent Maintenance Services Real-Time

Documentation Resource Library Earthing Transformer Manufacturer

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

Certifications Earthing Transformer Manufacturer

FAQ for Earthing Transformer Manufacturer

Can the technical design be revised after order confirmation if the grid scheme changes later?

Minor adjustments such as modification of auxiliary winding voltage, sensor configuration or enclosure accessories are usually feasible before casting starts.

Once the epoxy winding casting and curing process is completed, core electrical parameters including zero-sequence impedance and vector group cannot be changed.

If the grid grounding scheme, required fault current or short-time withstand duration changes after casting, a redesign and remanufacture will be required.

Any design change request should be submitted as early as possible, and we will issue an updated technical datasheet, cost and delivery revision for approval.

Is site commissioning guidance included, and what work will the technical engineer cover on site?

Remote commissioning guidance is included as standard. On-site engineer attendance is an optional service that can be added under the contract.

When engineers attend site, they will check mechanical installation, earthing connection, cable termination quality, sensor wiring, and coordinate with the protection team to verify zero-sequence loop logic.

They will also cross-check measured zero-sequence impedance against factory values, guide energization steps and record initial running data.

The on-site service does not cover civil construction, cable laying or protection relay programming unless these extra items are clearly listed in the service scope.

Can you support third-party witness testing or independent inspection before shipment?

Third-party witness testing is available upon request. We can coordinate the factory test schedule to accommodate inspectors from the buyer, engineering consultant, certification body or power utility.

Witnessed tests typically include winding resistance, vector group verification, insulation resistance, zero-sequence impedance measurement, power frequency withstand and partial discharge tests. All test procedures follow IEC standards, and the full test data will be signed off by both sides.

If the client requires additional special tests beyond the standard routine scope, we can assess feasibility, timeline and extra cost separately in advance.

Is Rockwill earthing transformer available in both oil-immersed and dry-type versions?

Yes. Rockwill earthing transformers are available in both oil-immersed and cast-resin dry-type versions. Oil-immersed units suit outdoor high-capacity applications. Dry cast resin models are preferred for indoor sites with strict fire safety requirements (substations, data centers). Auxiliary secondary winding, PT/CT monitoring assemblies can be equipped for both types.

What are the advantages of the dry-type design and copper foil windings?

Vacuum-cast epoxy thin insulation (1–3mm) resists thermal-cycling cracks, is moisture resistant and flame retardant, and is maintenance-free. Both HV and LV windings use copper foil for partial discharge <10 pC, excellent lightning impulse withstand, and high short-circuit resistance.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO