Model NO. Pole Mounted outdoor vacuum recloser/Reclosure-38kV
Rated voltage 38kV
Rated normal current 400A
Rated short circuit breaking current 12.5kA
Power frequency withstand voltage 85kV/min
Rated lightning impulse voltage 185kV
manual closing No
Series RCW

Description

As a pioneering OEM in China's recloser sector, we leverage decades of R&D expertise to set industry benchmarks, operate a fully autonomous production system, and deliver reliable solutions for power grid projects.

The RCW series automatic circuit recloser is specifically designed for 38kV overhead distribution lines and substation applications in 50/60Hz power systems. It integrates control, protection, measurement, communication, fault detection, and online monitoring of switching status. The RCW series combines a vacuum interrupter, current transformers, a permanent magnetic actuator, and an intelligent controller into a compact, high-performance unit.

Features

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

  • Solving the dual challenges of tropical heat and humidity

  • Resistant to salt fog corrosion, suitable for offshore / coastal power applications

  • Fully sealed design, preventing sand and dust from affecting

  • Operable in wide temperature range: -30°C to +40°C, handling extreme temperature variations

RCW Vacuum Reclosers Spring mechanism

Pole Mounted outdoor vacuum recloser/Reclosure Spring mechanism

Product Showcase Video

Parameters

Rated maximum voltage

38kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

12.5kA

Rated peak value withstand current

31.5kA

Rated 1min power frequency withstand voltage (Three-phase Epoxy resin pole)

85kV

Rated lightning impulse voltage (Three-phase Epoxy resin pole)

185kV

Operation sequence

C-0.3-CO-180-CO (Spring mechanism)

Mechanical life

n:10000 (Spring mechanism)

Power supply and operating voltage     

110/220V (Customized)

Ratio of current transformer

400/1A (Customized)

Number of voltage sensors (Three-phase Epoxy resin pole)

≤6

Opening time

≤50ms (Spring mechanism)

Closing time

≤60ms (Spring mechanism)

Minimum creepage distance

31, level 4 (mm/kV)

Minimum distance between phases

360mm

Potential transformer

110/220V (Customized)

Cable length

6,8,12m (Customized)

Cable clamp (Three-phase Epoxy resin pole)

4-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

 

With optional relay protection & logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(⁽¹⁾)

Over-voltage protection / Under voltage protection

Programmable protection relay curves (total 10 nos ANSI/IEC curves)

Cold load pickup protection TCC + Hot line tag

Earth protection E/F SEF + Zone- Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support

Modbus communication protocol is optional

IEC 60870-501 communication protocol support

IEC 60870-5-104 communication protocol support

The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language

With optional functions for use

Rated currents, System phase current,

Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency

power (kWh), reactive power (kVarh), power factor

With optional reclosing interval for user pre-program

reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note:mean should customized by manufacturer if needed

External dimensions

Pole Mounted outdoor vacuum recloser/Reclosure-38kV

RCW Vacuum Reclosers Physical Photo

Pole Mounted outdoor vacuum recloser/Reclosure Physical Photo

Environmental requirement

Maximum temperature:

+40°C

Minimum temperature:

-30°C

Monthly average humidity

95%

Humidity:

90%

Above sea level:

2500m or higher

Ambient air Not apparently polluted by corrosive and flammable gas, vapor

 

What are the mechanical failures of outdoor vacuum reclosers?

Operating Mechanism Faults:

Spring-Operated Mechanism:

  • Spring Fatigue: Spring fatigue is a common issue. If the spring remains compressed for a long time or is frequently operated, it may lose its elasticity, causing the closing speed to slow down or the closing position to be inaccurate. Additionally, mechanical transmission components of the spring-operated mechanism, such as connecting rods and toggle arms, can wear out, deform, or become stuck, affecting the accuracy and reliability of the opening and closing operations.

Permanent Magnet-Operated Mechanism:

  • Magnet Demagnetization: Demagnetization of the permanent magnet is a potential fault in permanent magnet-operated mechanisms. High-temperature environments, strong vibrations, or prolonged exposure to high currents can weaken the magnetic properties of the permanent magnet, affecting the performance of the operating mechanism. Furthermore, faults in the control circuit of the permanent magnet-operated mechanism, such as capacitor aging or electronic component failure, can also lead to abnormal opening and closing operations.

Transmission Component Faults:

  • Loose or Detached Connecting Rods: In outdoor vacuum reclosers, the transmission connecting rods may loosen or even detach over time due to vibration, corrosion, or other factors. This can prevent the opening and closing actions from being transmitted properly, causing the recloser to fail to operate correctly.

  • Wear or Breakage of Pivot Pins: Pivot pins can wear out during rotation. Severe wear can increase the clearance between transmission components, affecting the precision of the opening and closing actions. If a pivot pin breaks, it can directly interrupt the transmission chain of the recloser, preventing it from performing opening and closing operations.

Solutions for outdoor vacuum Auto Circuit recloser

  • Revolutionizing Outdoor High-Voltage Grid Protection over Conventional Breakers-- Reclosers
    Ⅰ. Core Functional Positioning Differences1. Recloser: Intelligent Self-Healing Switch Essence: Integrates arc-extinguishing system, operating mechanism, and intelligent control unit. Capable of autonomous fault detection → tripping → time-delayed reclosing → locking. Core Advantages: Programmable Operation Sequences: Supports customizable sequences (e.g., "one fast + three delayed" or "two fast + two delayed") to distinguish transient/permanent faults. Example: First fast trip clears transien

Reference Projects for outdoor vacuum Auto Circuit recloser

  • Rockwill Ukraine 186 Units 12kV Outdoor Vacuum Recloser Project Success Case
    In response to the operational characteristics of Ukraine’s local power grid and targeting harsh high-latitude outdoor working conditions, we rely on core technologies of intelligent reclosing and self-healing to precisely adapt to the complex grid environment with frequent thunderstorms and drastic diurnal temperature variations, steadily promoting the automatic and intelligent upgrade of regional rural power grids and suburban distribution networks.01 Project Overview1.1 Project BackgroundIn 2

Documentation Resource Library outdoor vacuum Auto Circuit recloser

RCW-F38N/630-20 MV Outdoor Vacuum Recloser
Public.
RCW-F38N/630-20 MV Outdoor Vacuum Recloser
Drawings
English
DEKRA Recloser Test Report
Public.
DEKRA Recloser Test Report
Test Report
English
15kV/27kV/38kV outdoor auto break vacuum recloser
Restricted.
15kV/27kV/38kV outdoor auto break vacuum recloser
Brochure
English
PDF
PDF
10 to 38kV auto vacuum break recloser Catalog
Restricted.
10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
PDF
PDF
38kV automatic recloser technology specification
Restricted.
38kV automatic recloser technology specification
Technical Data
English
PDF
PDF

Certifications outdoor vacuum Auto Circuit recloser

FAQ for outdoor vacuum Auto Circuit recloser

What are the key differences between Rockwill's RCW series recloser and a ZW32-type vacuum circuit breaker?

The ZW32-type VCB is a basic circuit breaker or demarcation switch without built-in auto-reclosing logic, whereas the RCW series is specifically engineered as a full-function recloser with integrated protection, sensors, and communication for smart grid applications.

Unlike the ZW32, which requires an external controller for automation, the RCW series complies with IEC 62271-111 and ANSI C37.60, and is supported by complete type test reports.With silicone rubber or epoxy insulation offering superior aging resistance and low water absorption, the RCW series is the professional choice for international distribution automation projects.

Does Rockwill offer a cost-effective alternative that is more budget-friendly than the standard RCW+ series?

Yes. The RCWP, a cost-optimized option in the RCW+ series, features dual sensors, flagship controller, and 30,000 operations with permanent magnet three-phase linkage, while offering downgrade options (lock box removal, lockout removal, sensor/controller downgrade) so customers pay only for what they need.

Related Q&A for outdoor vacuum Auto Circuit recloser

Q: Rockwill Recloser commissioning questions collection
4
2 8
4
2 8
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO