占位边距

SF6 Gas Insulated Metal-clad switchgear for MV Substation Distribution- 25.8 to 40.5kV

  • SF6 Gas Insulated Metal-clad switchgear for MV Substation Distribution- 25.8 to 40.5kV

Key attributes

Brand ROCKWILL
Model NO. SF6 Gas Insulated Metal-clad switchgear for MV Substation Distribution- 25.8 to 40.5kV
Rated voltage 40.5kV
Rated frequency 50/60Hz
Maximum operating voltage 40.5kV
Series RGIS

Description

The RGIS series of SF6 gas - insulated metal - clad switchgear is specifically designed for three - phase three - wire 50/60 Hz systems with a maximum voltage of 40.5 kV. With a rated voltage reaching up to 40.5 kV, it features either horizontally or vertically installed vacuum circuit breakers. The switchgear encompasses a comprehensive set of components like vacuum circuit breakers, meters, and relays.

Key Features

  • Excellent Insulation Performance

  • Reliable Arc - Extinguishing Performance

  • Fully Enclosed Structure

  • Modular Design

  • Good Explosion - Proof Performance

  • Perfect Anti - Misoperation Function

  • Low Maintenance Workload

Technology parameters

Designation of type Unit RGIS - G10 RGIS - G20 RGIS - G80 RGIS - G90
Rated voltage kV 25.8 40.5 40.5 27.5
Rated power frequency withstand voltage kV 50 95 95 95
Rated lightning impulse withstand voltage kV 125 185 185 185
All voltage values apply for an insulating gas pressure, absolute, 20℃ kPa 110 110 110 110
Rated frequency Hz 50/60 50/60 50/60 50/60
Rated busbar current A up to 2000 up to 1250 up to 1250 up to 1250
Rated feeder current A 630/ 1250/ 2000 630/ 1250 630/ 1250/ 2000 630/ 1250/ 2000
Rated peak withstand current kA 63 80 80 80
Rated short time current 4 seconds kA 25 31.5 31.5 31.5
Rated short circuit breaking current of circuit breaker kA 25 31.5 31.5 31.5
Rated short circuit making current of circuit breaker kA 63 80 80 80
Rated operating sequence - O - 0.3s - CO - 3min - CO
Closing time ms 75 60±5 60±5 60±5
Opening time ms 60 40±5 40±5 40±5
Insulating gas - SF₆
Rated filling pressure, absolute, 20℃ kPa 130
Minimum operating pressure, absolute, 20 ℃kPa kPa 120
Rated data: Auxiliary voltage V 220DC /110-125V DC

Device structure

SF6 Gas Insulated Metal-clad switchgear Device structure

 

SF6 Gas Insulated Metal-clad switchgear Device structure

Working Environment Conditions

Environmental Parameter Standard Value
Ambient air temperature — upper limit +40 °C
Ambient air temperature — 24 h average +35 °C
Ambient air temperature — lower limit –25 °C
Altitude above sea level ≤ 1 000 m
Relative humidity — 24 h average ≤ 95% (at +40 °C)
Relative humidity — monthly average ≤ 90%
Water vapour pressure — 24 h average ≤ 2.2 kPa
Water vapour pressure — monthly average ≤ 1.8 kPa
Solar radiation ≤ 1 000 W/m²
Wind speed (outdoor) ≤ 34 m/s (mild)
Pollution degree (indoor) Class II
SF₆ gas decomposition products ≤ 1 μL/L (SO₂F₂)

Typical Application Scenarios

  • Medium-Voltage Substation Distribution
  • Industrial Plant Power Distribution
  • Urban Rail Transit Power Supply
  • Renewable Energy Generation (Solar/Wind)
  • Data Center Power Distribution
  • Commercial Complex Distribution

Reference Projects for RMU

  • Rockwill RGIS Case Study and Gas Insulated Switchgear Project in Ghana
    Focusing on the demand for improved distribution network reliability in Ghana, 11kV R-GIS gas-insulated switchgear is adopted. Integrating advantages of compact design, weather-resistant protection and intelligent management, it adapts to limited installation space and complex tropical local environments. It supports the upgrading of regional power distribution infrastructure and realizes safe, stable, maintenance-free and efficient operation.01 Project Overview1.1 Project BackgroundGhana, as a

Documentation Resource Library RMU

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

FAQ for RMU

Does the RGIS support intelligent monitoring?

Yes. The switchgear encompasses comprehensive components including meters, relays, and control units, supporting intelligent grid control and automation. Compatible with SCADA and remote monitoring systems.

Is the RGIS series maintenance-free?

The fully enclosed SF₆ insulated structure isolates all live parts from external environmental impacts, ensuring low maintenance workload throughout the service life. SF₆ gas insulation eliminates dust, moisture, and corrosion concerns.

What operating mechanism is used?

The RGIS features vacuum circuit breakers (horizontally or vertically installed) with an operating sequence of O-0.3s-CO-3min-CO. Closing time is 60±5 ms and opening time is 40±5 ms — providing rapid and reliable switching.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO