| Brand | ROCKWILL |
| Model NO. | Single-phase vacuum Auto recloser OEM ODM Manufacturer-21.9kV |
| Rated voltage | 21.9kV |
| Rated normal current | 400A |
| Rated short circuit breaking current | 12.5kA |
| Power frequency withstand voltage | 85kV/min |
| Rated lightning impulse voltage | 185kV |
| manual closing | No |
| Series | RCW |
This recloser is highly customizable, offering a wide range of relay protection logics (such as instantaneous/timed over-current, directional over-current, zero-sequence/earth fault protection, and programmable ANSI/IEC curves) as well as comprehensive communication protocols (RS-232/485, DNP3.0, Modbus, IEC 60870-5-101/104, and GPRS).
It also allows users to customize rated parameters and reclosing intervals, and features an event recording capacity of up to 10,000 records, including fault and normal operation logs.

RWK351 tool: Configure, Manage, Control and Design. Protection and Communications Configuration tools for ROCKWILL’s Products
Configuration Management Software‑Class defining protection settings management for ROCKWILL devices. Locally and Remotely configure and control ROCKWILL Reclosers.

| Item | Unit | data |
|---|---|---|
| Rated maximum voltage | kV | 21.9 |
| Rated maximum current | A | 400/630/800/1250 |
| Rated frequency | Hz | 50/60 |
| Rated short circuit breaking current | kA | 12.5/16/20/25* |
| Rated peak value withstand current | kA | 31.5/40/50/63* |
| Rated 1min power frequency withstand voltage (Dry/Wet) | kV |
E: 70 F: 85 G: 90 |
| Rated lightning impulse voltage | kV |
E: 170 F: 185 G: 195 |
| Operation sequence | s | C-0.5-CO-2-CO-5-CO |
| Mechanical life | n. | 30000 |
| Power supply and operating voltage | V | 110/220, Customized |
| Ratio of current transformer | A | 400/1, Customized |
| Number of voltage sensors | n | E: ≤1F: ≤2M: ≤2 |
| Opening time | ms | M: ≤20 |
| Closing time | ms | M: ≤30 |
| Minimum creepage distance | mm/kV | 31, Level 4 |
| Potential transformer | V | 110/220, Customized |
| Cable length | m | 6, 8, 12, Customized |
| Cable clamp | — |
E: 2-hole NEMA F: 4-hole NEMA |
| Lightning arrester | n | ≤2 |
| Mounting type | — | Single / double column |
| 3-phase combination | — | provide |
Note:All parameters in the above table can be customized according to project requirements. As a professional Vacuum Recloser/Reclosure China Supplier, we provide flexible OEM/ODM solutions for voltage rating, current rating, CT configuration, control logic and communication options.
This single-phase automatic recloser is also available as an Outdoor Recloser/Reclosure For Sale product for distribution network and rural line applications.

|
With optional relay protection & logics for user choice |
Instantaneous over-current protection Timing over-current protection Negative sequence over-current protection Directional over-current protection(⁽¹⁾) Over-voltage protection / Under voltage protection Programmable protection relay curves (total 10 nos ANSI/IEC curves) Cold load pickup protection TCC + Hot line tag Earth protection E/F SEF + Zone- Sequence Co-ordination More relay functions can be customized |
|
With optional communication protocols & I/O port for user choice |
RS-232 and RS-485 ports supporting DNP3.0 communication protocol support Modbus communication protocol is optional IEC 60870-501 communication protocol support IEC 60870-5-104 communication protocol support The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language |
|
With optional functions for use |
Rated currents, System phase current, Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency power (kWh), reactive power (kVarh), power factor |
|
With optional reclosing interval for user pre-program |
reclosing times setting support Dead time setting support |
|
With events recording function |
SOE 10000 operations record Fault record and normal operation record Note:mean should customized by manufacturer if needed |


|
Maximum temperature: |
+40°C |
|
Minimum temperature: |
-30°C |
|
Monthly average humidity |
95% |
|
Humidity: |
90% |
|
Above sea level: |
2500m or higher |
|
Ambient air Not apparently polluted by corrosive and flammable gas, vapor |
This controller for Outdoor Single-phase vacuum recloser integrates a dedicated local operation panel. On-site parameter configuration, local operation and fault information review can be realized directly. Many general controllers do not have built-in panels and need to connect an external third-party HMI for local human-machine interaction.
Ordinary distribution controllers mostly only collect position signals from auxiliary switches. This controller, matched for Outdoor Single-phase vacuum recloser, is natively integrated with on-line monitoring of closing and opening. It can monitor the operating status of closing and opening in real time and grasp the operation condition of the recloser body.
It supports multiple MV voltage classes including 21.9kV/22kV/24kV/25.8kV, while most ordinary reclosers are built for a single fixed voltage.
Built on full-chain independent R&D and production instead of simple assembly. It achieves 10,000+ mechanical operations, longer than economy-grade reclosers and cuts utility maintenance expenses.
The Rockwill standard smart recloser offers high precision with a wide measuring range (2A–16,000A). Simply ensure your normal current is within this standard range when making a selection.
Yes. In addition to the standard 2A–16,000A range, Rockwill provides custom-configured units for ultra-low current measurement and protection in the 0.1A–2A range.