占位边距

Single-phase vacuum Auto recloser OEM ODM Manufacturer-21.9kV

  • Single-phase vacuum Auto recloser OEM ODM Manufacturer-21.9kV
  • Single-phase vacuum Auto recloser OEM ODM Manufacturer-21.9kV

Key attributes

Brand ROCKWILL
Model NO. Single-phase vacuum Auto recloser OEM ODM Manufacturer-21.9kV
Rated voltage 21.9kV
Rated normal current 1250A
Rated short circuit breaking current 25kA
Power frequency withstand voltage 85kV/min
Rated lightning impulse voltage 185kV
manual closing No
Series RCW

Description

The 21.9kV single-phase automatic recloser is an intelligent outdoor switching device designed for medium-voltage distribution networks. Using vacuum arc-extinguishing technology, it can quickly interrupt fault currents and effectively isolate short-circuit, overload and abnormal operating conditions. The single-phase structure makes it especially suitable for single-phase laterals, rural distribution lines, long feeders and sectionalizing applications.
Equipped with an intelligent controller, the unit supports automatic reclosing to restore power after transient faults while locking out permanent faults. Its compact outdoor design, vacuum interrupter and corrosion-resistant housing allow stable operation in high temperature, severe cold, high humidity and dusty environments.
As a professional Vacuum Recloser/Reclosure China Supplier, we provide reliable single-phase reclosing solutions for distribution automation, fault isolation and grid reliability improvement. This product is also available as an Outdoor Recloser/Reclosure For Sale option for projects requiring flexible OEM/ODM configuration and dependable outdoor performance.

Product Showcase Video

Single-phase Outdoor Vacuum Reclosers Controller

This recloser is highly customizable, offering a wide range of relay protection logics (such as instantaneous/timed over-current, directional over-current, zero-sequence/earth fault protection, and programmable ANSI/IEC curves) as well as comprehensive communication protocols (RS-232/485, DNP3.0, Modbus, IEC 60870-5-101/104, and GPRS).

It also allows users to customize rated parameters and reclosing intervals, and features an event recording capacity of up to 10,000 records, including fault and normal operation logs.

Single-phase vacuum Auto Circuit recloser Controller

Key Features

  • Single-phase Vacuum Design: Uses vacuum arc-extinguishing technology to achieve fast fault interruption, low maintenance and long service life.
  • Automatic Reclosing Logic: Distinguishes between transient and permanent faults, restoring power quickly for temporary faults and locking out permanent faults.
  • Compact Outdoor Structure: Rugged enclosure with strong environmental adaptability, suitable for -40°C to +70°C operating conditions.
  • Intelligent Monitoring: Supports real-time measurement of current, voltage and other electrical parameters, with data upload and remote control capability.
  • High Safety and Reliability: Equipped with mechanical and electrical interlocks to prevent misoperation, with a long-life design supporting tens of thousands of mechanical operations.
  • Flexible OEM/ODM Support: Rated voltage, current, CT ratio, control logic and communication options can be customized for different distribution network projects.

PC software for controller Testing, Setting, programing, Update

RWK351 tool: Configure, Manage, Control and Design. Protection and Communications Configuration tools for ROCKWILL’s Products

Configuration Management Software‑Class defining protection settings management for ROCKWILL devices. Locally and Remotely configure and control ROCKWILL Reclosers.

Single-phase vacuum Auto Circuit recloser for controller Testing

Parameters

Item Unit data
Rated maximum voltage kV 21.9
Rated maximum current A 400/630/800/1250
Rated frequency Hz 50/60
Rated short circuit breaking current kA 12.5/16/20/25*
Rated peak value withstand current kA 31.5/40/50/63*
Rated 1min power frequency withstand voltage (Dry/Wet) kV

E: 70

F: 85

G: 90

Rated lightning impulse voltage kV

E: 170

F: 185

G: 195

Operation sequence s C-0.5-CO-2-CO-5-CO
Mechanical life n. 30000
Power supply and operating voltage V 110/220, Customized
Ratio of current transformer A 400/1, Customized
Number of voltage sensors n E: ≤1F: ≤2M: ≤2
Opening time ms M: ≤20
Closing time ms M: ≤30
Minimum creepage distance mm/kV 31, Level 4
Potential transformer V 110/220, Customized
Cable length m 6, 8, 12, Customized
Cable clamp —

E: 2-hole NEMA

F: 4-hole NEMA

Lightning arrester n ≤2
Mounting type — Single / double column
3-phase combination — provide

Note:All parameters in the above table can be customized according to project requirements. As a professional Vacuum Recloser/Reclosure China Supplier, we provide flexible OEM/ODM solutions for voltage rating, current rating, CT configuration, control logic and communication options.

This single-phase automatic recloser is also available as an Outdoor Recloser/Reclosure For Sale product for distribution network and rural line applications.

Controller Description

The single-phase recloser controller integrates protection, control, monitoring, measurement and metering functions. It supports multiple relay protection logics, including overcurrent, negative-sequence, directional, over/under-voltage and earth-fault protection, with ANSI/IEC curve options and customizable protection settings.
The controller is equipped with RS-232/RS-485 communication interfaces and supports multiple power communication protocols, including GPRS/GSM remote communication. Reclosing parameters can be pre-programmed, and the unit provides electrical parameter measurement together with up to 10,000 SOE event and fault records for efficient fault analysis and O&M.
Single-phase Automatic Recloser OEM ODM China 21.9kV

With optional relay protection & logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(⁽¹⁾)

Over-voltage protection / Under voltage protection

Programmable protection relay curves (total 10 nos ANSI/IEC curves)

Cold load pickup protection TCC + Hot line tag

Earth protection E/F SEF + Zone- Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support

Modbus communication protocol is optional

IEC 60870-501 communication protocol support

IEC 60870-5-104 communication protocol support

The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language

With optional functions for use

Rated currents, System phase current,

Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency

power (kWh), reactive power (kVarh), power factor

With optional reclosing interval for user pre-program

reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note:mean should customized by manufacturer if needed

Single-phase Automatic Recloser OEM ODM China 21.9kV

External dimensions

Single-phase vacuum Auto Circuit recloser External dimensions

Environmental requirement

Maximum temperature:

+40°C

Minimum temperature:

-30°C

Monthly average humidity

95%

Humidity:

90%

Above sea level:

2500m or higher

Ambient air Not apparently polluted by corrosive and flammable gas, vapor

 

 

Solutions for outdoor vacuum Auto Circuit recloser

  • Integrated Sandstorm Defense Solution with Recloser Upgrades for Northern Nigeria
    Project Background: Nigeria's Intensifying Sandstorm ChallengNorthern Nigeria (e.g., Kano, Ogun States) confronts severe desertification threats (63% land area), enduring over 60 annual Sandstorm events originating from the Sahara. Dust infiltration causes:• Equipment Damage: Sandstorm-driven particulate corrosion triggers 40% higher failure rates in power infrastructure. Industrial line shutdowns cost Nigeria’s economy >$10M yearly.• Economic Erosion: Farmland degradation and forced relocati
  • Indonesia's Smart Recloser System: Integrated Solution for Volcanic Ash and Coastal Salt Corrosion Mitigation
    Project BackgroundIndonesia is situated within the Pacific Ring of Fire, experiencing frequent natural disasters that pose multiple threats to its power system:Geographical Risks: Volcanic Ash: The country has 127 active volcanoes. Eruptions produce Volcanic Ash containing sulfides and dust, accelerating corrosion of electrical equipment and causing insulator flashovers. Coastal High Salt Fog & Corrosion: With an 81,000 km coastline, salt fog permeation leads to severe Coastal Salt Corrosion
  • Vietnam Flood-Resilient Recloser Solution: Solving Immersion Protection in Monsoon Zones
    Project BackgroundVietnam's tropical monsoon climate causes annual floods lasting 4-5 months, severely damaging power infrastructure. The 2020 central Vietnam floods paralyzed grids, delaying rescue operations. Traditional circuit breakers fail under water immersion, and manual restoration is inefficient. Although flood control infrastructure has improved, rapid power recovery remains a critical gap. Recloser devices, if unprotected, are highly vulnerable to flood-induced short circuits. Enhanci

Reference Projects for outdoor vacuum Auto Circuit recloser

  • DTEK Grid Upgrade: Operation of Rockwill 10kV Smart Recloser in -40°C Extreme Cold Environment Ukraine Case Study
    As a benchmark for Chinese‑manufactured medium‑voltage distribution equipment going global, Rockwill established in‑depth cooperation with DTEK Kyiv Power Grid, Ukraine. Tailored outdoor vacuum recloser solutions were mass‑deployed to address existing weaknesses in local 10 kV distribution networks, comprehensively improving regional power supply reliability and automation to build a flagship distribution grid modernization project in Kyiv.01 Project Background: Core Pain Points of DTEK Kyiv Dis
  • Successful Case of 170 Sets of 11kV Automatic Recloser Project in Kenya
    Against the backdrop of quality upgrading for Kenya’s urban and rural power grids, 11kV auto-reclosers deliver reliable performance to suit local climates and grid conditions. It enables rapid fault isolation and efficient operation and maintenance, forming a core safeguard for the upgrading of Kenya’s urban and rural distribution networks.01 Project Overview1.1 Project BackgroundIn May 2023, 170 sets of 11kV Automatic Reclosers (Model: RCW12M) were officially supplied and applied to the medium-

Documentation Resource Library outdoor vacuum Auto Circuit recloser

RCW MV Triple-single recloser Brochure
Public.
RCW MV Triple-single recloser Brochure
Brochure
English
27kV automatic recloser technology specification
Public.
27kV automatic recloser technology specification
Technical Data
English
10 to 38kV auto vacuum break recloser Catalog
Restricted.
10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
PDF
PDF
15kV/27kV/38kV outdoor auto break vacuum recloser
Restricted.
15kV/27kV/38kV outdoor auto break vacuum recloser
Brochure
English
PDF
PDF
RCW MV Triple-single Recloser catalog
Restricted.
RCW MV Triple-single Recloser catalog
Catalogue
English
PDF
PDF
RCW MV outdoor vacuum recloser installation manual
Restricted.
RCW MV outdoor vacuum recloser installation manual
Operating Instruction
English
PDF
PDF

FAQ for outdoor vacuum Auto Circuit recloser

Does the controller for Outdoor Single-phase vacuum recloser come with an operation panel? What are its advantages compared with general controllers?

This controller for Outdoor Single-phase vacuum recloser integrates a dedicated local operation panel. On-site parameter configuration, local operation and fault information review can be realized directly. Many general controllers do not have built-in panels and need to connect an external third-party HMI for local human-machine interaction.

What’s the difference in closing/opening monitoring for our Outdoor Single-phase Vacuum Recloser controller vs ordinary distribution controllers?

Ordinary distribution controllers mostly only collect position signals from auxiliary switches. This controller, matched for Outdoor Single-phase vacuum recloser, is natively integrated with on-line monitoring of closing and opening. It can monitor the operating status of closing and opening in real time and grasp the operation condition of the recloser body.

What advantages does the RCW recloser have over conventional reclosers?

It supports multiple MV voltage classes including 21.9kV/22kV/24kV/25.8kV, while most ordinary reclosers are built for a single fixed voltage.

Built on full-chain independent R&D and production instead of simple assembly. It achieves 10,000+ mechanical operations, longer than economy-grade reclosers and cuts utility maintenance expenses.

How to select current sensor or current transformer specifications for Rockwill Smart Recloser?

The Rockwill standard smart recloser offers high precision with a wide measuring range (2A–16,000A). Simply ensure your normal current is within this standard range when making a selection.

Does Rockwill offer an MV Smart Auto Recloser capable of measuring primary currents as low as 0.1A?

Yes. In addition to the standard 2A–16,000A range, Rockwill provides custom-configured units for ultra-low current measurement and protection in the 0.1A–2A range.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO