占位边距

Primary air insulated RMU

  • Primary air insulated RMU
  • Primary air insulated RMU
  • Primary air insulated RMU
  • Primary air insulated RMU
  • Primary air insulated RMU

Key attributes

Brand ROCKWILL
Series RMR,RGIS,REC

Description

An air-insulated ring main unit engineered for primary distribution networks — no SF6, no fluorinated gas, with sealed vacuum interruption. Designed for 12–24kV rings where reliable, clean and low-maintenance protection is required.

12–24kV            Primary MV class

630A                  Busbar current

20kA/3s             Short-time withstand

Air                      SF6-free insulation

Primary air insulated RMU

What is a primary air insulated RMU?

A ring main unit insulated by air rather than SF6, built for primary distribution — the part of the network closest to the supply point where reliability matters most.

A primary air insulated RMU uses conditioned air for phase-to-earth and phase-to-phase insulation, paired with a sealed vacuum interrupter for current breaking. Unlike SF6 units, it contains no greenhouse gas, so there is nothing to leak, report or recover. It is sized for 12–24kV primary rings feeding distribution transformers, and type-tested to IEC 62271 for dependable, long-life service.

Air insulation

Conditioned air sealed in the tank provides clean, breathable, non-toxic insulation with zero global warming potential.

Vacuum interruption

Sealed vacuum interrupters handle current breaking independently of the insulation medium, proven over decades.

Primary-grade rating

Type-tested withstand levels for primary distribution, with optional protection and metering for demanding networks.

Primary air insulated RMU

Advantages for primary distribution

SF6-free

No fluorinated gas sealed in the tank — zero GWP and no F-gas compliance burden.

Safe on site

Air does not displace oxygen; no asphyxiation risk in cable pits, kiosks or basements.

Low maintenance

No gas-density top-ups, just sealed vacuum parts and air-pressure monitoring.

Long service life

Sealed construction and vacuum interrupters designed for decades of operation.

Recyclable

Steel enclosure and copper busbar recycle as standard materials at end of life.

OEM / ODM

Built to your ring layout and brand, with IEC 62271 documentation for tenders.

Primary air insulated RMU

Typical specifications

Representative values; the certified datasheet is prepared on request — contact us.

Parameter Typical value
Rated voltage 12kV / 24kV
Power frequency withstand 50kV (1 min)
Lightning impulse withstand 125kV
Rated frequency 50 / 60 Hz
Insulation medium Conditioned air — SF6-free, GWP 0
Breaking device Sealed vacuum interrupter
Busbar rated current 630A (up to 1250A on request)
Rated short-time withstand 20kA / 3s (25kA on request)
Configuration 2 ring incomers + transformer feeder (switch-fuse / VCB)
Standard IEC 62271-1, -102 / -103

Solutions for Primary air insulated RMU

  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire distr
  • Rockwill Medium-Voltage SF6-Free Gas-Insulated Switchgear Series – From RMR to REC and RAR
    Within Rockwill's SF6-free product portfolio, the RMR, REC, and RAR series all adopt gas-insulated, hermetically sealed structures that fully enclose high-voltage live parts in stainless steel tanks, ensuring complete sealing and maintenance-free operation. The three series share a similar modular design philosophy, but differ significantly in insulation medium, technical positioning, voltage coverage, and application scenarios.Core DifferencesIn terms of insulation medium and environmental char

Reference Projects for Primary air insulated RMU

  • Rockwill RGIS Case Study and Gas Insulated Switchgear Project in Ghana
    Focusing on the demand for improved distribution network reliability in Ghana, 11kV R-GIS gas-insulated switchgear is adopted. Integrating advantages of compact design, weather-resistant protection and intelligent management, it adapts to limited installation space and complex tropical local environments. It supports the upgrading of regional power distribution infrastructure and realizes safe, stable, maintenance-free and efficient operation.01 Project Overview1.1 Project BackgroundGhana, as a

Documentation Resource Library Primary air insulated RMU

EEHC Distribution materials specification for 24kv ring mian units
Restricted.
EEHC Distribution materials specification for 24kv ring mian units
Others
English
PDF
PDF
24kV SF6 Gas insulated Ring Main Unit (RMU)
Restricted.
24kV SF6 Gas insulated Ring Main Unit (RMU)
Brochure
English
PDF
PDF
   OMR Type Outdoor Gas Insulated Ring Main Unit
Restricted.
OMR Type Outdoor Gas Insulated Ring Main Unit
Catalogue
English
PDF
PDF
SM66 type 36kV 40.5kV air insulated Ring Main Unit (RMU)
Restricted.
SM66 type 36kV 40.5kV air insulated Ring Main Unit (RMU)
Catalogue
English
PDF
PDF
Air insulated Ring Main Unit (RMU)
Restricted.
Air insulated Ring Main Unit (RMU)
Catalogue
English
PDF
PDF

Certifications Primary air insulated RMU

FAQ for Primary air insulated RMU

Can it be built under our brand?

Yes. We manufacture primary air insulated RMUs for distributors and EPCs under OEM/ODM with your nameplate and documentation.

Is it really SF6-free?

Yes. No SF6 or fluorinated gas is sealed in the tank; the global warming potential is zero.

Is air insulation reliable in primary distribution?

Yes. When dimensioned and type-tested to the IEC 62271 withstand levels, conditioned air provides reliable insulation with sealed vacuum interruption.

What does "primary air insulated RMU" mean?

It is an air-insulated ring main unit built for primary distribution networks — the upstream part of the MV network — using conditioned air and vacuum interruption instead of SF6.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
WhatsApp
WhatsApp
Chat
Chen/CEO