Model NO. SF6 Ring Main Unit Switchgear Source Manufacturer-24kV
Rated voltage 24kV
Rated frequency 50/60Hz
Series RMR

Description

The SF6 gas-insulated switchgear RMR-24/630 is designed for medium-voltage power distribution systems with a rated voltage up to 24kV (25kV). It serves as a highly reliable Ring Main Unit (RMU) in power supply networks, providing fault isolation and sectionalizing capabilities. When equipped with smart distribution automation devices (FTU/DTU) and communication modules, it enables real-time monitoring and remote control for modern smart grids.

This product operates with a safe, fully sealed SF6 gas tank, ensuring a compact structure, longevity, and a maintenance-free lifecycle. It is in strict conformity with the international standard IEC 62271-105.

Product feature

  • Robust Panel Enclosure: The main enclosure is constructed from 2mm aluminum-zinc-coated (Alu-Zinc) steel plates using multi-bending technology. This design ensures high mechanical strength, excellent corrosion resistance, and an aesthetically precise finish.

  • Top-Mounted Busbar Compartment: The main busbar compartment is securely located at the top of the unit, facilitating safe and efficient interconnections with adjacent modular panels to form a complete switchgear assembly.

  • SF6 Gas-Insulated Load Break Switch (LBS): The core switching unit features a highly reliable Load Break Switch housed within a hermetically sealed SF6 gas tank, ensuring excellent arc-quenching capabilities and a maintenance-free lifecycle.

  • Spacious Cable Compartment: Occupying approximately 75% of the lower cabinet volume, this generously sized compartment provides ample room for power cable terminations, as well as the installation of high-voltage fuses, earthing switches, and potential transformers (PT).

  • Mechanism & Interlocking System: The operating mechanism chamber houses precision actuators, mechanical interlocks, position indicators, auxiliary contact trip coils, and charge status indicators. These components work together to provide foolproof "5-prevent" safety interlocking, strictly adhering to IEC safety protocols.

  • Low-Voltage (LV) Control Chamber: Conveniently located at the top front of the panel, the LV chamber is isolated from high-voltage areas. It is designed for housing protective relays, metering instruments, and motorized control units, ensuring safe access for operators.

  • Circuit Breaker Integration (Optional): Depending on the specific RMR-24/630 configuration, an SF6 or Vacuum Circuit Breaker (VCB) can be integrated below the load break switch for enhanced short-circuit protection.

Technical data

Item Unit Parameter Value
Rated Voltage (Ur) kV 24 (25)
Power Frequency Withstand Voltage (Ph-Gnd / Across Isolation) kV 50 / 60
Lightning Impulse Withstand Voltage (Ph-Gnd / Across Isolation) kV 125 / 145
Rated Current A 630
Active Load A 630
Closed Loop A 670
Off-load Cable Charging A 141
Earth Fault A 160
Earth Fault Cable Charging A 91
Making Capacity kA 40
Short-time Current (3 sec) kA 16

Environmental Conditions

  • Altitude: ≤ 2000 m (For >1000m applications, insulation is subject to Ka correction per IEC 62271-1).

  • Temperature Range: -40°C ~ +55°C

  • Relative Humidity: Daily mean ≤ 95%, Monthly mean ≤ 90%

  • Gradation of Earthquake Damage: ≤  Level 8

Solutions for Ring Main Unit

Documentation Resource Library Ring Main Unit

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

FAQ for Ring Main Unit

Does the RMR-24/630 support smart grid automation?

Yes. When equipped with smart distribution automation devices (FTU/DTU) and communication modules, the RMR-24/630 enables real-time monitoring and remote control, making it suitable for modern smart grid deployments.

Is the RMR-24/630 maintenance-free?

Yes. The fully sealed SF₆ gas tank ensures a compact, maintenance-free lifecycle. All high-voltage components are hermetically sealed, eliminating gas replenishment and internal inspection requirements throughout the designed service life.

What safety interlocking features does the RMR-24/630 offer?

The RMR-24/630 features a precision mechanism chamber housing actuators, mechanical interlocks, position indicators, auxiliary contacts, and charge status indicators. Together they provide foolproof "5-prevent" safety interlocking, strictly adhering to IEC safety protocols.

What is the enclosure design and durability?

The main enclosure is constructed from 2mm Alu-Zinc coated steel plates using multi-bending technology, ensuring high mechanical strength, excellent corrosion resistance, and a precise finish. The LV control chamber is isolated from HV areas at the top front, ensuring safe access for operators. The top-mounted busbar compartment facilitates safe and efficient interconnection with adjacent modular panels.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
WhatsApp
WhatsApp
Chat
Chen/CEO