占位边距
Rockwill delivers integrated electrical solutions for smart grids, urban infrastructure, renewable integration, and industrial applications. From medium-voltage automation to EV charging networks and prefabricated substations, our systems ensure stable, efficient, and future-ready power distribution. Customized. Connected. Reliable.

Oil-Immersed Grounding Transformer for Chile’s Mining and Renewable Energy Networks


Chile has one of the more developed power standards systems in South America, with a grid architecture shaped by its unique geography. The northern mining and renewable energy hubs, such as the Atacama Desert PV clusters, commonly operate at 34.5kV or 23kV medium-voltage levels, under demanding environmental conditions.
To address high altitude, high salinity, intense solar radiation and long-distance transmission, Rockwill provides customized oil-immersed grounding transformer solutions.
This solution is designed for Chilean distribution networks to establish a reliable artificial neutral point, improving system safety and operational stability for renewable integration, mining power supply and long feeder circuits.
China Grounding Transformer Manufacturer

Key Challenges: Why Chile Requires a Customized Approach?

1.Voltage level compatibility

Chile’s medium-voltage distribution networks commonly use 34.5kV and 23kV, rather than the 35kV/10kV systems frequently seen in domestic Chinese projects. Equipment not designed for local voltage levels may face insulation coordination and system compatibility issues.

2.Harsh environments accelerate equipment aging

Northern mining areas are located at high altitude with strong UV exposure, dust and salt mist, while southern coastal regions experience high humidity. Conventional outdoor equipment may suffer from reduced insulation performance, insufficient creepage distance or accelerated corrosion over long-term operation.

3.High capacitive earth fault current on long lines

Chile’s narrow and elongated geography means mine collection circuits and renewable export lines are often long. During a single-phase earth fault, capacitive current can cause intermittent arcing and temporary overvoltages, potentially affecting downstream VFDs, inverters and other sensitive equipment.

4.High O&M costs at remote sites

Mining sites, PV plants and wind farms are often widely dispersed, making manual inspection costly. Customers typically prefer equipment with high reliability, low maintenance requirements and suitability for unattended or lightly attended operation.

Technical Solution: Purpose-Built Design

1.Customized insulation and voltage design

  • Rated voltage can be designed for 34.5kV or 23kV system requirements.
  • HV bushings can be specified as reinforced porcelain or composite type, with creepage distance optimized for heavily polluted environments.
  • As grounding transformers normally operate only during fault conditions, winding design must meet the required zero-sequence current and thermal stability duration.

2.Oil-immersed structure for harsh environments

  • Fully sealed corrugated tank or plate radiator design reduces air and moisture ingress, slowing insulation oil aging.
  • Tank surfaces can be treated with anti-corrosion coatings to improve resistance to salt mist, humidity and industrial atmospheres.

Grounding Transformer Factory China

 

3.High-altitude derating compensation

  • For high-altitude mining sites, air density reduction is considered in temperature rise calculations.
  • Radiator area, oil volume and layout can be optimized to maintain stable thermal performance at altitude.

4.Low zero-sequence impedance connection

  • ZN,yn11 connection is recommended, providing low zero-sequence impedance and a stable artificial neutral point.
  • The transformer can be coordinated with a neutral earthing resistor to limit single-phase earth fault current and enable fast fault clearance by protection relays.

Economic Value: Benefits for End Users

1.Lower lifecycle cost

Although oil-immersed equipment may have a higher initial cost than some simplified dry-type alternatives, the sealed structure reduces insulation oil aging and lowers inspection and maintenance frequency at remote sites, helping reduce long-term O&M expenditure.

2.Reduced unplanned outage losses

Proper earthing resistor coordination helps suppress arcing overvoltages during single-phase earth faults, reducing the risk of damage to downstream crushers, ball mill VFDs, PV inverters and other equipment, thereby minimizing production downtime.

3.Simplified civil works and installation

Rockwill oil-immersed grounding transformers have a compact structure and high protection level. They can be installed on outdoor platforms or under simple shelters, reducing dependence on separate fire-rated buildings or complex climate-control facilities, which helps lower civil costs and footprint.

Compliance and Documentation: Supporting Project Acceptance

  • Product design can follow the IEC 60076 series standards.
  • Type test reports, material certificates and technical drawings can be provided to support preparation of documentation for Chilean SEC review.
  • Seismic conditions can be considered in structural design, with reinforced or flexible arrangements for the base, bushings and lead connections to improve reliability during transport, installation and operation.
  • For long ocean shipments to Chilean ports, heavy-duty wooden crates with moisture protection measures can be used to reduce the risk of moisture ingress.

MV Grounding Transformer OEM China

Typical Applications and Delivery Support

Typical Applications

  • Neutral earthing for 34.5kV distribution networks in large copper and lithium mines.
  • Earthing for 23kV/34.5kV booster stations in Atacama PV plants.
  • Neutral earthing for wind farm collection systems.
  • Long-distance overhead line and cable hybrid supply systems.

Delivery and After-Sales Support

  • Spanish installation and maintenance manuals can be provided.
  • Common spare parts such as sealing gaskets, silica gel for breathers and pressure gauges can be supplied with the equipment.
  • Remote video support is available for installation, commissioning and operational checks.

Key Technical Parameters

Item Typical Configuration
Rated voltage 23kV / 34.5kV
Vector group ZN,yn11
Rated output Customized per system requirement
Thermal stability duration 10s / 30s / 60s optional
Insulation level Compliant with IEC 60076 requirements
Protection class IP54 / IP55 optional, subject to enclosure or installation arrangement
Service environment High altitude, high salinity, strong UV, humid areas
Corrosion protection Configurable for coastal or industrial environments
Packing Heavy-duty wooden crate with moisture protection measures
 

Request Technical Documents

For the 34.5kV/23kV oil-immersed grounding transformer selection chart, technical data sheet or Spanish version of this solution, please contact the Rockwill technical team.

Deployed Equipment

  • Oil-Immersed Neutral Grounding Transformer OEM ODM 17.5kV-40.5kV
    Rockwill three-phase oil-immersed Z-type earthing transformers are engineered for medium-voltage power systems that require a stable artificial neutral point. With an optimized zigzag (ZN) winding and a fully sealed oil-immersed tank, these units provide reliable neutral grounding for ungrounded or resistance-grounded networks between 17.5 kV and 40.5 kV.They limit ground fault currents, suppress arc grounding overvoltage, and improve relay protection sensitivity. Designed and manufactured in co
  • China Oil Immersed Grounding Transformer Manufacturer 15kV-35kV
    Rockwill three-phase oil-immersed Z-type earthing transformers are designed for medium-voltage power systems requiring a reliable artificial neutral point. Featuring a fully sealed oil-immersed structure with optimized zigzag (ZN) winding, these transformers provide stable neutral grounding for ungrounded or low-current grounded systems from 15 kV to 35 kV. They effectively suppress arc grounding overvoltage, limit ground fault currents, and enhance grid stability. Manufactured in compliance wit
  • Customized Neutral Grounding Transformer Manufacturer-33kV
    Rockwill’s three-phase oil-immersed zigzag earthing transformer is designed for medium-voltage networks that do not have a natural neutral point. By creating a reliable artificial neutral, it allows arc suppression coils, neutral grounding resistors and protection devices to be connected safely and effectively.The transformer uses an optimized ZN or ZNyn11 winding arrangement inside a fully sealed oil tank. Under normal operation, it draws very little current. During a single-phase earth fault,
  • Three Phase Neutral Grounding Transformer Supplier 15kV-36kV
    Rockwill’s three-phase neutral grounding transformers are designed to create a reliable artificial neutral point for medium-voltage power systems between 15 kV and 36 kV. Built with an optimized zigzag (ZN/ZNyn) winding and a fully sealed oil-immersed tank, they provide a safe grounding reference for ungrounded, impedance-grounded, or delta-connected networks.These units help suppress arc grounding overvoltage, limit ground fault currents, and improve relay protection sensitivity. Manufactured i
  • IEC Oil-Immersed Zigzag Earthing Transformer Manufacturer-11kV to 35kV
    Rockwill three-phase oil-immersed zigzag earthing transformers are engineered to provide a stable artificial neutral point for medium-voltage power systems. Featuring a fully sealed oil-immersed structure with optimized zigzag (ZNyn) winding, these transformers provide stable neutral grounding for ungrounded or low-current grounded systems from 11 kV to 35 kV. They effectively suppress arc grounding overvoltage, limit ground fault currents, and enhance grid stability. Manufactured in compliance
  • Three Phase Z-type Oil-Immersed Earthing Transformer OEM China 10kV-35kV
    Rockwill three-phase oil-immersed Z-type earthing transformers are designed for medium-voltage power systems that require a stable artificial neutral point. Built with a fully sealed oil-immersed structure and optimized zigzag (ZNyn) winding, they provide reliable neutral grounding for ungrounded or low-current grounded systems from 10 kV to 35 kV.These transformers effectively suppress arc grounding overvoltage, limit ground fault currents, and improve overall grid stability. Manufactured in co
Leave your contact information to receive the full technical documentation and a free consultation from our engineers. Get the Solution Guide
Recent Solutions
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO