占位边距

China Distribution Line Automatic Step Voltage Regulator Supplier 6kV-34.5kV

  • China Distribution Line Automatic Step Voltage Regulator Supplier 6kV-34.5kV

Key attributes

Brand ROCKWILL
Series RVR-1
Rated Voltage 7.62-34.5kV
Rated Current 50-546 A
Capacity 38-660 kVA
Rated Frequency 50/60 Hz

Description

The RVR-1 single-phase automatic step voltage regulator from China factory achieves automatic on-load voltage regulation by adjusting the transformer ratio through the on-load tap changer. The intelligent controller RVR samples, analyzes, judges, and processes the voltage on the line, then sends signals to drive the on-load tap changer to adjust the voltage.
The RVR-1 voltage regulator is equipped with self-protection lockout functions, including line fault, overload, overcurrent, and undervoltage protection. The RVR-1 voltage regulator also features a unique on-load tap changer design that prevents arcing during voltage regulation, ensuring a service life of up to two million operations. The RVR-1 voltage regulator features a fully sealed design, with a high level of protection and excellent weather resistance, allowing for long-term maintenance-free operation.

RVR-1 Automatic Step Voltage Regulator | Field Operation Video

Advantages of the product 

  • High precision: Within the set voltage regulator range, it automatically adjusts the voltage in 32 loaded steps.
  • Long service life: The unique voltage-tapping switch design prevents arcing during voltage adjustment, ensuring a mechanical operational lifespan of 1 million cycles.
  • Low maintenance: Fully sealed design with high protection rating, excellent weather resistance, allowing for long-term maintenance-free operation, with a design life of 20 years.
  • Low loss: The single-phase design can minimize iron losses and reduce no-load losses, with total losses being less than 0.1%.
  • Strong overload capability: Designed with a rated capacity for a 55°C temperature rise, it can handle an overload of 12% at a 65°C temperature rise. 

Cutaway Illustration

Single Phase Automatic Voltage Regulator Cutaway Illustration

Technical Specifications

Voltage (kV) Current (A) Capacity (kVA) BIL (kV) Power Frequency Withstand Voltage (kV) Insulation Class
7.62

50 38 60/75 20 A
100 76
150 114
219 167
328 250
438 333
546 416
13.8 50 69 95/125 38
100 138
150 207
200 276
300 414
400 552
14.4 50 72 95/125 38
100 144
200 288
300 432
400 576
19.92 50 100 170/200

70
100 200
167 333
200 400
335 667
34.5 50 165 170/200

70
100 330
150 495
200 660

Installation diagram for three single phase regulators connected in triphasic 

Three single-phase regulators connected to a triphasic line in closed delta providing the system with 15% of the regulation range.

Single Phase Automatic Voltage Regulator Installation diagram

On-site Operation Photo

Single Phase Automatic Voltage Regulator On-site Operation Photo

Service environment

  • Air temperature: Maximum temperature: +40℃;
  • Minimum temperature: -40℃
  • Humidity: Daily average humidity 100%.
  • Above sea level: Maximum installation altitude: 1000m.

Note: If it needs to be installed in plateau areas with an altitude higher than 1,000 meters, it is essential to consult with the manufacturer to take necessary measures to strengthen insulation during the ordering process. 

Typical Applications

  • Utility Grids: The voltage regulator compensates for drops in rural or long-distance lines
  • Industrial Power: The step voltage regulator stabilizes voltage for factories with fluctuating loads
  • Renewable Energy: The voltage regulator smooths variations in solar/wind farm connections
  • Commercial/Municipal: The step voltage regulator ensures stable power for hospitals, data centers, and plants
  • Mining/Offshore: The voltage regulator handles high fluctuations in demanding environments

Solutions for voltage regulator

  • Innovative Solutions of Step Voltage Regulators in Power Distribution Systems
    1 Executive SummaryVoltage Management Challenges in Modern Distribution Networks: Long-distance feeders causing voltage drop; Distributed energy resource (DER) integration leading to bidirectional power flow; Load fluctuations causing frequent voltage variations.Technical Features of Step Voltage Regulators (SVRs): Employs tap-changing technology to alter transformer winding turns ratio, achieving a ±10% voltage adjustment range (typically in 32 steps, 0.625% per step); Core advantage
  • Zanzibar project – voltage regulator selection misalignment with load requirements: root cause analysis & solution
    I. Incident BackgroundThe 33kV line voltage regulator (13 taps, 4% step per tap) supplied by our company for the Zanzibar project has been commissioned and is currently in operation. However, during nighttime periods of low load, the regulator has repeatedly caused the low-voltage side voltage at the downstream factory to rise to 420V, triggering overvoltage shutdowns of production machinery. Following these incidents, the customer specified a maximum permissible low-voltage side tolerance of 41
  • Midnight Voltage Surge to 420V Causes Plant Shutdown? The RVR-1 Automatic Voltage Regulator Breaks the
    Introduction: A "Low-Load Hours" Crisis That Struck in the Early MorningBetween 1:00 AM and 7:30 AM on August 24, while most plants were in their low-production overnight window, one facility was forced to shut down three times in succession due to voltage spikes reaching 420V. This was not a grid fault, but a classic case of "off-peak voltage over-limit."During late-night hours when grid load is light, line losses are minimal, and excess reactive power causes the terminal voltage to rise sharpl
  • Zanzibar Project Voltage Regulation Technical Solution: Multi-Level Voltage Stabilization and Precision Control in 380V/415V Mixed-Use Scenarios
    1. Core Project Challenges and Reference Standards1.1 Core Parameters System Constraint:The client proposed a 410V upper limit on the low-voltage side. This requirement stems from the need to protect 380V-rated equipment against overvoltage in scenarios where both 380V and 415V equipment are used. This 410V limit is not a contractual hard requirement but rather a system-level design reference value. With the implementation of a dedicated supply scheme for specific equipment, independent analysis
  • Comprehensive Solution for Replacing RS Series Stepping Voltage Regulators
    Ⅰ. Analysis of Original Equipment Specifications and System Requirements AssessmentCore Features (ABB RS Series Stepping Voltage Regulator): Voltage Regulation Range: 100V-440V AC input, output 0.7-1.0 times rated voltage (e.g., 400V input yields 280-400V output). Control Interface: Supports 4-20mA analog signal or RS485 digital communication (Modbus protocol), default parameters: 9600 baud rate, no parity, 8 data bits, 1 stop bit. Load Capability: 5A-16A RMS current, suitable for high-power ste

Reference Projects for voltage regulator

  • Successful Case of 263 Units of 33kV Oil-immersed 32-step Voltage Regulator Controller Project in Bangladesh
    Successful Case of 263 Units of 33kV Oil-immersed 32-step Voltage Regulator Controller Project in Bangladesh01 Overall Project Overview1.1 Project BackgroundIn June 2024, 263 units of 33kV oil-immersed 32-step voltage regulator controller were officially delivered and applied to the Bangladesh Medium Voltage Distribution Network Upgrade Project. R&D and manufactured by Rockwill, these devices are used for voltage stability regulation, load fluctuation adaptation and power supply quality impr

Documentation Resource Library voltage regulator

6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Restricted.
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
PDF
PDF
Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English
RVR-1 Type  Single Phase Automatic Voltage Regulator  6kV-34.5kV
Restricted.
RVR-1 Type Single Phase Automatic Voltage Regulator 6kV-34.5kV
Operating Instruction
English
PDF
PDF
RVR-1  Single Phase Automatic Voltage Regulator 6kV-34.5kV
Restricted.
RVR-1 Single Phase Automatic Voltage Regulator 6kV-34.5kV
Catalogue
English
PDF
PDF

Certifications voltage regulator

FAQ for voltage regulator

How does the RVR-1 Step Voltage Regulator achieve automatic voltage regulation?

The RVR-1 Step Voltage Regulator automatically adjusts line voltage in 32 loaded steps by using its intelligent controller to analyze line voltage and drive the on-load tap changer.

What is the operational lifespan and maintenance requirement of the RVR-1 Step Voltage Regulator?

The RVR-1 Step Voltage Regulator features a unique anti-arcing tap changer ensuring 1 to 2 million operations, and a fully sealed design offering a 20-year design life with long-term maintenance-free operation.

What protection features are built into the RVR-1 Step Voltage Regulator?

The RVR-1 Step Voltage Regulator is equipped with self-protection lockout functions against line faults, overload, overcurrent, and undervoltage.

What are the loss and overload capabilities of the RVR-1 Step Voltage Regulator?

Total losses of the RVR-1 Step Voltage Regulator are less than 0.1%. Designed for a 55°C temperature rise, it can handle an overload of 12% at a 65°C temperature rise.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO