占位边距

Customization Live tank SF6 Circuit Breaker Manufacturer -123kV 145kV

  • Customization Live tank SF6 Circuit Breaker Manufacturer -123kV 145kV

Key attributes

Brand ROCKWILL
Series RHB
Rated voltage 123kV/145kV
Rated current up to 4000kA
Rated peak withstand current up to 158 kA
Rated frequency 50/60Hz

Description

The Live tank SF6 gas circuit breaker (equipped with CT - type spring operating mechanism) is an outdoor three - phase AC 50HZ high - voltage power transmission equipment.It is used to interrupt and close the rated current, interrupt the fault current, or switch the circuit, so as to achieve the control and protection of the power transmission line.

This circuit breaker can not only perform single - pole opening, closing, and fast auto - reclosing operations, but also, through the electrical interlocking among the three poles, conduct three - pole opening, closing, and fast auto - reclosing operations.The circuit breaker adopts the Live tank SF6 gas circuit breaker principle and has the characteristics of simple structure, low required operating power, high reliability, easy installation, and low noise. 

Live Tank SF6 Circuit Breaker Factory China

Features

  • Three-phase post porcelain insulator with common single-spring mechanism, compact outdoor layout.

  • SF₆ serves as insulation & arc-quenching medium; three poles gas interlinked for stable performance.

  • Fitted with pointer density relay for real-time gas pressure & density monitoring.

  • Self-blast arc extinction reduces operating power and boosts mechanical efficiency.

  • Customized design available per client’s specific project demands.

Pole Column

Each pole column is an airtight unit. From top to bottom, the pole columnis composed of the upper outgoing line plate, arc quenching chamber,lower outgoing line plate, supporting porcelain bushing, insulating tie rod,direct - acting seal, and mechanism operation shaft.

SF6 circuit breaker pole column structure

Technical parameters

Item Unit Parameter
Rated voltage kV 123 145
Rated frequency Hz 50/60
Rated current A up to 4000
Rated short-time withstand current, up to 3 s kA up to 63
Rated peak withstand current kA up to 158 
Rated short-duration power-frequency withstand voltage, 1 min kV 230 275
Power-frequency withstand voltage, 1 min across open contacts kV 265 315
Rated lightning impulse withstand voltage, 1.2/50 μs kV 550 650
Rated lightning impulse withstand voltage, 1.2/50 μs, across open contacts kV 650 750
Rated filling pressure (abs. at 20 ℃) circuit-breaker MPa 0.6
Minimum functional pressure (abs. at 20 ℃) circuit-breaker MPa 0.5
Temperature range (ambient) ℃ -30~+40
Type of installation — outdoor
Partial discharge capacity pC <5
SF₆ leakage rate per year — <0.5%
Maintenance cycle Year 30

Note:Custom voltage ratings and special parameters are available upon request. As an experienced SF6 Live Tank Circuit Breaker Manufacturer, we are committed to providing solutions that precisely match your project specifications. Contact us for more details on custom configurations.

Dimension Drawing

 Live tank Circuit breaker installation dimensions

Service environment

  • Ambient temperature:-25℃ ~ +40℃

  • Altitude:<1000m

  • Wind speed:<34m/s

  • Daily temperature difference:<25℃

  • Solar irradiance:<0.1w/cm²

  • Monthly average relative humidity:<90%

  • Ice-coating thickness:<10mm

  • Seismic acceleration resistance:Horizontal <0.2g, vertical <0.1g

  • Installation location:Outdoor

Solutions for Live tank SF6 Circuit-Breaker

  • Rockwill Company's SF6 Circuit Breaker Solution for Substations in the Ethiopian Highlands
    I.Project BackgroundThe Ethiopian highlands feature high altitudes (average over 2,500 meters), extreme cold climates (winter temperatures as low as -30°C), and location within the seismically active East African Rift Zone. These conditions pose significant challenges to power equipment: SF6 Liquefaction Risk: At 0.6 MPa operating pressure, SF6 gas liquefies at -25°C. Extreme cold may cause liquefaction, leading to degraded insulation and loss of arc-extinguishing capability. Seismic Threats: Th
  • Rockwill's SF6 Circuit Breaker Solution for 33kV Substations in Nigeria
    Project BackgroundNigeria&amp;rsquo;s tropical climate, characterized by year-round high temperatures (annual average of 35&amp;deg;C) and humidity (&amp;ge;80%), poses significant challenges to the sealing integrity, insulation performance, and gas management of electrical equipment. Rockwill was contracted to upgrade a 33kV substation, deploying its proprietary HV-type SF6 circuit breaker to address critical issues: Sealing Failure Risks: Accelerated aging of seals due to heat and water ingres
  • SF6 Circuit Breaker Seal Failure Analysis and HNBR Upgrade Strategy for Venezuela 24kV Network
    Core Challenge: The 24kV outdoor SF6 circuit breakers operated by Venezuela's National Electric Corporation (CORPOELEC), under the C5-M high salt mist corrosion environment along the Lake Maracaibo coast and an annual average temperature of 32&deg;C, experience accelerated O-ring compression set, causing the SF6 annual leakage rate to deteriorate from the design value of &le;0.1% to over 1% in actual operation, frequently triggering low-pressure lockout alarms. This is one of the key contributin
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor InstallationIn high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues: Pollution &amp; Insulation Degradation Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach Class IV, resulting in insufficient creepage distance and triggering flashov

Documentation Resource Library Live tank SF6 Circuit-Breaker

RHB Type Live tank SF6 gas circuit breaker
Restricted.
RHB Type Live tank SF6 gas circuit breaker
Catalogue
English
PDF
PDF
RHB Hybird Switchgear Catalog
Restricted.
RHB Hybird Switchgear Catalog
Selection Guide
English
PDF
PDF
RHB-72.5 Live tank SF6 gas circuit breaker FLYER
Public.
RHB-72.5 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-170  Live tank SF6 gas circuit breaker FLYER
Public.
RHB-170 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-52 Live tank SF6 gas circuit breaker FLYER
Public.
RHB-52 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-123 Live tank SF6 gas circuit breaker
Public.
RHB-123 Live tank SF6 gas circuit breaker
Drawings
English
RHB-145 Live tank SF6 gas circuit breaker
Public.
RHB-145 Live tank SF6 gas circuit breaker
Drawings
English
RHB-170(m) Live tank SF6 gas circuit breaker
Public.
RHB-170(m) Live tank SF6 gas circuit breaker
Drawings
English
RHB-245 Live tank SF6 gas circuit breaker
Public.
RHB-245 Live tank SF6 gas circuit breaker
Drawings
English
RHB Outdoor SF6 Circuit Breaker  Installation and Operation Instruction
Restricted.
RHB Outdoor SF6 Circuit Breaker Installation and Operation Instruction
Operating Instruction
English
PDF
PDF

FAQ for Live tank SF6 Circuit-Breaker

Where is the arc extinguishing chamber located in a live tank breaker versus a dead tank breaker?

In a live tank breaker, the arc chamber is mounted at the top or side of the column, exposed to ambient air. In a dead tank breaker, the arc chamber is placed inside the metal tank, fully sealed.

How do the insulation designs of a live tank breaker and a dead tank breaker differ?

A live tank breaker relies on porcelain columns, air, or composite insulating materials for phase-to-ground insulation. A dead tank breaker uses SF₆ (or other insulating gases) inside a sealed metal tank, providing high insulation strength unaffected by external humidity or contamination.

What is the core structural difference between a live tank breaker and a dead tank breaker?

A live tank breaker (also called a porcelain column breaker) mounts its core components on top of porcelain insulators with an open, visible layout. A dead tank breaker encloses all core parts — including the arc extinguishing chamber and current path — inside a grounded metal tank, achieving a highly integrated and compact structure.

What voltage ratings are available for your live tank SF6 circuit breaker, and can it be customized?

The live tank SF6 gas circuit breaker is offered in standard 123kV and 145kV configurations, with rated current up to 4000A and short-time withstand current up to 63kA.

As a professional SF6 Live Tank Circuit Breaker Manufacturer, we also customize voltage ratings, rated current, and operating parameters to match your specific substation and project requirements. Contact us for a tailored solution.

How much maintenance does an outdoor SF6 live tank circuit breaker require?

Our SF6 circuit breakers are designed for minimal maintenance, with a maintenance cycle of up to 30 years. SF₆ serves as both the insulation and arc-quenching medium, and the annual SF₆ leakage rate is kept below 0.5%.

A built-in pointer density relay provides real-time gas pressure and density monitoring, so you can trust stable, long-term outdoor operation with low operating power and high reliability.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO