| Brand | ROCKWILL |
| Series | RHB |
| Rated voltage | 40.5 kV/52 kV |
| Rated current | up to 4000A |
| Rated short-time withstand current(3s) | up to 31.5 kA |
| Rated peak withstand current | up to 80kA |
| Rated frequency | 50/60 HZ |
As a leading Outdoor SF6 Circuit Breaker Manufacturer, we present the RHB 52kV Live Tank Circuit Breaker, engineered for 50/60Hz three-phase outdoor power distribution systems.
It provides reliable switching and fault protection for transformers, overhead lines, and power equipment, with robust mechanical performance for frequent operation under rated conditions.
Self-blast arc extinction design: Low operating power, outstanding breaking performance to suppress switching overvoltage effectively.
Three-phase post porcelain insulator construction: Outdoor-type insulation structure, compact layout, high pollution resistance.
Optimized spring operating mechanism: High-strength cast aluminum frame with floating-tooth energy storage structure, full energy stored within 8s; centralized layout for opening/closing springs & oil buffers, low operating impact and contact rebound. Filled with imported low-temperature grease, stable service from -50℃ to +55℃, mechanical life over 10,000 times.
Pointer density relay fitted: Real-time monitoring on SF₆ gas pressure & density for safe running.
Optional built-in / external CT: Built-in CT adopts high-permeability microcrystalline alloy core, accuracy up to 0.2/0.2S for rated current ≥200A; external CT facilitates maintenance and capacity upgrade.
Dry sealed inner cavity filled with SF₆: Avoid internal condensation and dampness. Key auxiliary parts sourced from imported/joint-venture brands; exposed fittings adopt hot-dip galvanization or stainless steel for superior anti-corrosion.
High altitude adaptability: Suitable for installation altitude up to 3000m with premium insulation property.
| Rated voltage | kV | 52 | |
| Rated frequency | Hz | 50/60 | |
| Rated current | A | up to 4000 | |
| Rated short-time withstand current(3s) | kA | up to 31.5 | |
| Rated peak withstand current | kA | up to 80 | |
| 1min power-frequency withstand voltage (earth) | kV | 95 | |
| 1min power-frequency withstand voltage (across open contacts) | kV | 118 | |
| Lightning impulse 1.2/50 μs (earth) | kV | 200 | |
| Lightning impulse 1.2/50 μs (across open contacts) | kV | 250 | |
| Rated filling pressure(abs.@20℃) | MPa | 0.5 | |
| Minimum functional pressure(abs.@20℃) | MPa | 0.4 | |
| Ambient temperature range | ℃ | -25~+40 | |
| Installation type | - | Outdoor | |
| Partial discharge | pC | <5 | |
| Annual SF₆ leakage rate | - | <0.5% | |
| Maintenance cycle | Year | 30 | |
Note:Beyond the standard specifications listed above, we offer extensive customization to meet diverse grid requirements. Our manufacturing capabilities cover a comprehensive voltage range from 40.5kV to 550kV.
Whether you need specific ambient temperature adaptations or unique parameter configurations, our engineering team is ready to provide tailored high-voltage solutions for your project.


Ambient temperature: -25℃ ~ +40℃
Altitude: <1000m
Wind speed: <34m/s
Daily temperature difference: <25℃
Solar irradiance: <0.1W/cm2
Monthly average relative humidity: <90%
Ice-coating thickness: <10mm
Seismic acceleration resistance: Horizontal <0.2g, vertical <0.1g
Installation location: Outdoor
Circuit breaker model & specification
Rated parameters: voltage, rated current, short-circuit breaking current
Application environment: ambient temperature, installation altitude, pollution class
Control & motor operating voltage of operating mechanism
CT configuration: internal/external type, transformation ratio, secondary load & combination
Spare parts & special tools (separate ordering required)
In a live tank breaker, the arc chamber is mounted at the top or side of the column, exposed to ambient air. In a dead tank breaker, the arc chamber is placed inside the metal tank, fully sealed.
ABB’s high-voltage live-tank vacuum breakers are reliable but costly with long lead times. Hitachi Energy is mature yet lacks local high-voltage track records and smart features. Schneider Electric excels in 40.5kV distribution but is limited in voltage range and extreme performance.
In contrast, Rockwill offers up to 363kV SF₆-free vacuum solutions with fast local service and spare parts delivery. Featuring robust mechanisms, full smart functions, and superior resistance to extreme cold, heavy salt fog, and short-circuit currents, our breakers ensure long maintenance-free service and lower LCC.
We provide a 20-year warranty for this circuit breaker. This long-term guarantee reflects our confidence in the product's durability, supported by its 30-year maintenance cycle and high-quality components from imported or joint-venture brands.
Yes. Beyond standard specifications, we offer extensive customization capabilities. Our manufacturing range covers a comprehensive voltage spectrum, allowing us to tailor insulation distances and breaking chamber designs to meet your specific grid requirements.
The inner cavity is dry-sealed and filled with SF6 gas to effectively prevent internal condensation and dampness. Additionally, all exposed fittings adopt hot-dip galvanization or stainless steel materials to provide superior anti-corrosion protection against pollution and humidity.
The unit is fitted with a pointer density relay. This device allows for real-time visual monitoring of the SF6 gas pressure and density, ensuring that the insulation status is always within safe running parameters.