| Brand | ROCKWILL |
| Series | RHB |
| Rated voltage | 40.5kV/52kV/123kV/145kV/363kV |
| Rated current | up to 4000A |
| Rated peak withstand current | up to 158kA |
| Rated frequency | 50/60Hz |
The RHB type Live tank SF6 gas circuit breaker is specifically designed for outdoor high-voltage environments. Utilizing self-blast arc-extinguishing technology and taking advantage of the excellent insulating and arc-extinguishing properties of SF₆ gas, it can quickly quench arcs and ensure efficient interruption of fault currents.
With a compact and robust structure, it adapts to various harsh weather conditions. It boasts high reliability and a long service life, which significantly reduces maintenance frequency, making it a key device for enhancing the safety and stability of power systems.
We also provide Outdoor SF6 Circuit Breaker OEM/ODM services to meet customized project requirements.
SF6 gas is used for arc extinguishing
Monitor with a pointer-type density relay
Adopt the self-blast arc extinguishing principle
Adopt pointer-type density relays for pressure and density monitoring

RHB-52
| Item | Unit | Parameter |
|---|---|---|
| Rated voltage | kV | 52 |
| Rated frequency | Hz | 50/60 |
| Rated current | A | up to 4000 |
| Rated short-time withstand current, up to 3 s | kA | up to 63 |
| Rated peak withstand current | kA | up to 158 |
| Rated short-duration power-frequency withstand voltage, 1 min | kV | 95 |
| Power-frequency withstand voltage, 1 min across open contacts | kV | 95 |
| Rated lightning impulse withstand voltage, 1.2/50 μs | kV | 200 |
| Rated lightning impulse withstand voltage, 1.2/50 μs, across open contacts | kV | 250 |
| Rated filling pressure (abs. at 20 °C) circuit-breaker/other components | MPa | 0.5 |
| Minimum functional pressure (abs. at 20 °C) circuit-breaker/other components | MPa | 0.4 |
RHB-123/145
| Item | Unit | 123kV | 145kV |
|---|---|---|---|
| Rated voltage | kV | 123 | 145 |
| Rated frequency | Hz | 50/60 | |
| Rated current | A | up to 4000 | |
| Rated short-time withstand current, up to 3 s | kA | up to 63 | |
| Rated peak withstand current | kA | up to 158 | |
| Rated short-duration power-frequency withstand voltage,1min | kV | 230 | 275 |
| Power-frequency withstand voltage,1min across open contacts | kV | 265 | 315 |
| Rated lightning impulse withstand voltage,1.2/50 μs | kV | 550 | 650 |
| Rated lightning impulse withstand voltage,1.2/50 μs,across open contacts | kV | 650 | 750 |
| Rated filling pressure (abs. at 20℃) circuit-breaker | MPa | 0.6 | |
| Minimum functional pressure (abs. at 20℃) circuit-breaker | MPa | 0.5 | |
| Temperature range (ambient) | ℃ | -30~+40 | |
| Type of installation- | —— | outdoor | |
| Partial discharge capacity | pC | <5 | |
| SF₆ leakage rate per year | —— | <0.5% | |
| Maintenance cycle | Year | 30 | |
RHB-363
| Item | Unit | Parameter |
|---|---|---|
| Rated voltage | kV | 362 |
| Rated frequency | Hz | 50/60 |
| Rated current | A | up to 4000 |
| Rated short-time withstand current, up to 3 s | kA | up to 63 |
| Rated peak withstand current | kA | 158 |
| Rated short-duration power-frequency withstand voltage, 1 min | kV | 450 |
| Power-frequency withstand voltage, 1 min across open contacts | kV | 520 |
| Rated lightning impulse withstand voltage, 1.2/50 μs | kV | 1175 |
| Rated lightning impulse withstand voltage, 1.2/50 μs, across open contacts | kV | 1380 |
| Rated filling pressure (abs. at 20 ℃) circuit-breaker | MPa | 0.6 |
| Minimum functional pressure (abs. at 20 ℃) circuit-breaker | MPa | 0.5 |
RHB-40.5

RHB-72.5

RHB-123/145

RHB-170

RHB-252

RHB-362

| Ambient temperature | ‑30°C ~ +40°C |
| Altitude | <1000m |
| Wind speed | <34m/s |
| Daily temperature difference | <25°C |
| Solar irradiance | < 0.1W/cm² |
| Monthly average relative humidity | <90% |
| Ice‑coating thickness | <10mm |
| Seismic acceleration resistance | Horizontal <0.2g, vertical <0.1g |
| Installation location | Outdoor |
The core difference is the arc-extinguishing medium. A VCB uses a high vacuum inside a sealed ceramic or glass envelope — the vacuum rapidly diffuses ions and metal vapor after current zero, achieving arc extinction in <10 ms. An SF₆ CB uses sulfur hexafluoride gas, which has strong electron affinity — it captures free electrons to form heavy negative ions, quickly depleting the arc channel's conductivity.
In a live tank breaker, the arc chamber is mounted at the top or side of the column, exposed to ambient air. In a dead tank breaker, the arc chamber is placed inside the metal tank, fully sealed.
Live tank breakers are well-suited for outdoor high-voltage distribution with a dispersed layout. Dead tank breakers flexibly adapt to both indoor and outdoor applications, especially in space-constrained substations or where compact installation is required.
The RHB series covers a wide voltage range from 40.5kV up to 550kV. Standard models include 52kV, 123/145kV, 170kV, 252kV, and 363kV, with customized voltage ratings up to 550kV available upon request.
This extensive range allows us to provide tailored solutions for various transmission and distribution network levels, ensuring full compatibility with your specific grid infrastructure requirements.
The RHB breaker utilizes advanced self-blast arc extinguishing technology. This mechanism uses the energy generated by the arc itself to create the gas flow needed for extinction, rather than relying solely on mechanical piston action.
The key benefits are significantly reduced operating power requirements (allowing for smaller, more efficient operating mechanisms) and enhanced reliability in interrupting high fault currents (up to 63kA), leading to a longer mechanical life and lower maintenance costs.