Key attributes

Brand ROCKWILL
Series RVD
Rated voltage 145kV
Rated frequency 60Hz
Rated normal current 3000 A
Rated break time 50 ms
Rated short-circuit breaking current 63kA

Description

Product Overview

Based on this expertise, we have developed a SF6-free dead tank circuit breaker (DTCB) that is very similar to its SF6 predecessor. Using our g3 insulating and switching SF6-free technology, the new RVD-145 remains compact with the same footprint. Performance and life-cycle costs remain similar while offering a significant decrease in carbon footprint.

The SF6-free gas mixture used in the new RVD-145 works on the same well-known principle for insulation and breaking purposes as that of SF6 gas. Thus, the operational and maintenance procedures are similar to SF6 dead tank circuit breakers.The g3 gas is a mixture of carbon dioxide (CO2) with oxygen (O2) and an additive (C4F7N), whose physical properties are essential to g3. Its contribution to global warming is significantly lower than that of SF6 gas: reduced by roughly 99% on average.

Main Characteristics

  •  Advanced self-blast interrupters
  • Durable low-energy spring/spring operated mechanisms
  • 2 μs chopped wave 838 kV
  • Zero bar withstand capability

Ratings

IEC

VALUE

UNITS

Rated voltage

145

kV

Rated frequency

60

Hz

Rated insulation level

• at power frequency, dry
• at power frequency, wet

315

kV

275 / 315

kV

Lightning impulse

650

kV

Rated normal current

3000

A

Rated short-circuit breaking current

63

kA

Rated break time

50

ms

Rated operating sequence

O-CO-15s-CO / O-0.3s-CO-180s-CO

Dimensions

RATED MAX. VOLTAGE 145 kV
A (in/mm) 89.2/2264
B (in/mm) 73.85/1876
C (in/mm) 122.9/3120
D (in/mm) 167.5/4254
E (in/mm) 51.83/1316
F (in/mm) 137.4/3490
G (in/mm) 65.9/1674
H (in/mm) 107.85/2739.5
I (in/mm) 97.5/2476
J (in/mm) 51.83/1316

 High reliability SF6-free Dead Tank Circuit Breaker-145 kV

Technical Data

Ambient temperature range* -30° to +40°
 
-22° to +104°
Celsius/Fahrenheit
High seismic capability in accordance with IEEE 693-2018
Weight (without current transformers) 4,413/2,006 lb/kg

 

Solutions for SF6-free DTCB

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO