占位边距

SF6 Free/Pure Air Dead tank vacuum circuit breaker 12kV-145kV

  • SF6 Free/Pure Air Dead tank vacuum circuit breaker 12kV-145kV

Key attributes

Brand ROCKWILL
Series RVD
Rated voltage 12…145kV
lightning impulse withstand voltage 75…650kV
Rated short-circuit breaking current 25–50kA
Rated frequency 50/60Hz

Description

Product introduction

ROCKWILL® Electric is committed to providing customers with cutting-edge technology, competitive pricing, and superior after-sales services to advance automated distribution. 

As the power industry evolves, the miniaturization of electrical equipment represents a key future trend and an urgent need for current power consumers. 

Miniaturized electrical equipment not only saves land and civil engineering costs but also reduces the use of greenhouse gases like sulfur hexafluoride (SF₆), thereby meeting ecological and environmental protection requirements.

 Leveraging years of extensive experience in high-voltage electrical design and incorporating globally advanced technical design philosophies, our company has developed the latest RVD Dead Tank Vacuum Circuit Breaker. 

This product is tailored for power utilities and enterprises pursuing high power supply reliability, advancing distribution automation upgrades, and operating in harsh environments. It serves not just as a simple line switch but as a critical component in building smart, resilient distribution grids.

Main characteristic

  • Eco-friendly Design: SF₆ and fluorinated greenhouse gases free, adopting clean air for insulation with zero GWP; insulating gas can vent directly to atmosphere without greenhouse pollution.

  • High Operational Safety: Non-toxic air insulation produces no poisonous arc decomposition by-products; no special gas handling needed for maintenance or equipment decommissioning.

  • Outstanding Performance: Built on decades of proven vacuum interruption technology, it maintains stable breaking performance under rated normal and short-circuit currents. Hermetically sealed vacuum interrupter is maintenance-free throughout service life, with over 50-year service lifetime and first major inspection after minimum 25 years.

  • Wide Environmental Adaptability: Works reliably across -50℃ ~ +55℃; insulation air avoids liquefaction risk, available for both indoor and outdoor installation.

Product Structure 

Structural Aspect Key Components & Characteristics
Core Technology Vacuum interrupter technology + Clean air insulation.

 

This forms the foundation for achieving "zero harm".
Insulation Medium Clean air (80% nitrogen, 20% oxygen), with a Global Warming Potential (GWP) = 0, non-toxic and harmless.
Key Components 1. Vacuum interrupter chamber: Sealed design, maintenance-free for life.

 

2. Spring-operated mechanism: Mature and reliable technology.

 

3. Low-power instrument transformer (LPIT): Optional integration, combining voltage and current transformers into one unit, saving space.
Physical Structure Modular design, available in standard and compact versions (with LPIT), suitable for indoor/outdoor installation.

Main technical parameters

Item

Parameter

Rated voltage

12-145kV

Rated frequency

50/60Hz

Rated short-duration power-frequency withstand voltage (1 min)

42-275kV

Rated lightning impulse withstand voltage (1.2/50 μs)

75-650kV

Rated continuous current - bus bar / feeder bus coupler

1250-3150A

Rated short-circuit breaking current

25-50kA

Rated peak withstand current

63, 80, 100, 135kA

Rated short-time withstand current (up to 3 s)

25,31.5,40,50kA

Leakage rate per year and gas compartment (type tested)

<0.1%

Drive mechanism of circuit-breaker

stored energy spring

Rated operating sequence

O-0.3s-CO-3min-CO

 

CO-15s-CO

interrupter technology

vacuum

Insulation medium

clean air

Weight of SF₆ or other fluorinated green-house gases

0 kg

Rated filling pressure

0.8 MPa (abs.)

Bay width common pole drive

1000 mm

Ambient temperature range

-50℃~+55℃

Installation

Indoor/outdoor

First major inspection

>25 years

Expected lifetime

>50 years

Standards

IEC/IEEE

Optional LPIT

Optional Low-Power Instrument Transformer (LPIT) combines voltage and current transformer functions in one device. A single unit meets both protection and measurement requirements, allows flexible installation, and helps reduce the equipment's size and weight.

Service environment

  • Air temperature: Maximum temperature: +55℃; Minimum temperature: -50℃

  • Humidity: Daily average humidity 100%.

  • Above sea level: Maximum installation altitude: 1000m.

1. If it needs to be installed in plateau areas with an altitude higher than 1,000 meters, it is essential to consult with the manufacturer to take necessary measures to strengthen insulation during the ordering process.
2. When operating in an area with a temperature of -40℃, measures need to be taken to prevent SF₆ gas from liquefying.

Documentation Resource Library Dead Tank circuit breaker

RVD Dead tank SF6 Free/vacuum circuit breaker
Public.
RVD Dead tank SF6 Free/vacuum circuit breaker
Brochure
English
RVD-145  Dead tank vacuum circuit breaker
Public.
RVD-145 Dead tank vacuum circuit breaker
Brochure
English
RVD-145 Dead tank vacuum circuit breaker catalogue
Restricted.
RVD-145 Dead tank vacuum circuit breaker catalogue
Catalogue
English
Consulting
Consulting
Dead Tank Circuit Breakers Catalog
Restricted.
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting

FAQ for Dead Tank circuit breaker

Q: What are the core differences and key selection points of SF6 tank circuit breakers with voltage levels of 138kV/145kV/252kV?
A:

145kV is a mainstream standard grade in China, 138kV is an American standard specification, and 252kV is suitable for higher-voltage scenarios. Core differences and selection points: ① Insulation and parameters — the break spacing and rated SF6 pressure (0.7MPa) of 252kV are both higher than the other two; 138kV and 145kV can share some structures but require adjustment of the voltage sampling threshold; ② Key selection points — 138kV prioritizes matching interfaces of imported equipment, 145kV focuses on maturity, and 252kV needs to verify the breaking capacity of ≥63kA and the insulation coordination test report.

Q: What are the requirements for monitoring the gas decomposition products of the SF6 tank circuit breaker?
A:

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Q: What are the characteristics of the interrupter in a tank-type circuit breaker?
A:

The interrupter is typically installed inside the tank, resulting in a highly compact overall structure that enables efficient arc quenching within a limited space. Depending on the arc extinguishing principle and technical approach, the specific configuration of the interrupter may vary, but all designs include core components such as moving/stationary contacts, a nozzle, and insulating parts. During opening operation to interrupt the current, these components work together to achieve fast and reliable extinction of the arc.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO