占位边距

HV SF6 Live Tank Circuit Breaker OEM supplier 145kV-362kV

  • HV SF6 Live Tank Circuit Breaker OEM supplier 145kV-362kV

Key attributes

Brand ROCKWILL
Series RHB
Rated voltage 145 kV/252kV/362kV
Rated short-time withstand current up to 63 kA
Rated peak withstand current up to 158 kA
Rated frequency 50/60 Hz

Description

The RHB Series is a premier Live Tank SF6 Circuit Breaker China solution, engineered as a unified high-voltage platform rather than a medium-voltage extension. Covering a complete spectrum from 11kV to 362kV, it utilizes advanced self-blast arc extinction to minimize operating power while maximizing reliability for outdoor 50Hz transmission networks.

Key features include robust three-phase porcelain insulation, a stable CT-type spring mechanism with low noise, and a pointer density relay for continuous SF6 monitoring. Designed for single/three-pole switching and auto-reclosing, the RHB ensures superior environmental adaptability and grid safety.

Product Showcase Video

Core Advantages

  • Unified HV Platform Architecture: Designed natively for high-voltage applications, ensuring consistent quality and performance without "medium-to-high" voltage compromises.
  • Energy-Efficient Self-Blast Technology: Advanced arc extinction design reduces the required operating power, enhancing overall system efficiency.
  • Robust Environmental Adaptability: The three-phase outdoor porcelain post insulation structure is built to withstand extreme weather and pollution levels.
  • Precision Monitoring & Safety: Integrated pointer density relay provides real-time visualization of SF6 gas density, guaranteeing safe dielectric strength.
  • Reliable CT-Type Spring Mechanism: Proven mechanical design characterized by stable tripping/closing actions, low operational noise, and ease of maintenance/installation.

Main technical parameters

Item Unit 145kV 252kV 363kV
Rated voltage kV 145 252 363
Rated frequency Hz 50/60
Rated current A up to 5000
Rated short-time withstand current, up to 3 s kA up to 63
Rated peak withstand current kA up to 158
1min power-frequency withstand voltage (earth) kV 275 460 460
1min power-frequency withstand voltage (across open contacts) kV 315 530 530
Rated lightning impulse withstand voltage, 1.2/50 μs (earth) kV 650 1050 1175
Rated lightning impulse withstand voltage, 1.2/50 μs (across open contacts) kV 750 1200 1380
Rated filling pressure (abs. at 20 ℃) circuit-breaker MPa 0.6
Minimum functional pressure (abs. at 20 ℃) circuit-breaker MPa 0.5
Ambient temperature range ℃ -30~+40
Type of installation — Outdoor
Partial discharge pC <5
Annual SF₆ leakage rate — <0.5%
Maintenance cycle Year 30

Note: Beyond the standard ratings listed above, our engineering team supports flexible voltage customization ranging from 11kV to 550kV to meet specific grid requirements. We also offer tailored solutions for special frequency (60Hz) and extreme environmental conditions upon request.

Working Principle

Upon trip signal, trip spring drives the integrated moving assembly (cylinder, moving arc contact & connecting rod) downward. Main contacts separate first, shifting circuit current onto closed arc contacts; arc generates once arc contacts part.

For short-circuit breaking, massive arc energy heats surrounding SF6 gas and feeds high-temperature airflow into thermal expansion chamber to build high-pressure cold gas, closing the check valve. At current zero-crossing, high-pressure gas blasts across contact gap to quench arc efficiently.

Meanwhile, compression chamber’s excess pressure opens bottom elastic pressure relief valve to release redundant gas pressure, drastically cutting required operating work of the spring mechanism and optimizing breaking performance.

 Self-blast SF6 circuit breaker interrupter working principle

CT20 spring operating mechanism

Rotation principle The output crank arm converts the circular motion of the opening and closing operations output by the mechanism into horizontal motion through the connecting rod, transmission shaft, connecting plate and horizontal tie rod, so as to realize the opening and closing operations of the circuit breaker body.

There are opening and closing buffers (limiters) to absorb the residual energy after the moving contact finishes its movement and limit the terminal position of the moving contact 

HV Live Tank SF6 Circuit Breaker China

1.Closing spring 2. Oil buffer 3. Ratchet wheel 4. Energy - storage retaining pin 5. Pawl 6. Pawl shaft 7. Output crank arm 8. Large crank arm 9. Closing retaining pawl 10. Opening pawl

11. Opening electromagnet 12. Mechanical anti - tripping device 13. Closing pawl 14. Closing electromagnet 15. Energy storage retaining pawl 16. Opening spring 17. Output shaft 18. Cam 19. Energy - storage shaft 20. Closing retaining pin 

Service environment

Item Parameter
Ambient temperature -30°C ~ +40°C
Altitude <1000m
Wind speed <34m/s
Daily temperature difference <25°C
Solar irradiance <0.1W/cm²
Monthly average relative humidity <90%
Ice-coating thickness <10mm
Seismic acceleration resistance Horizontal <0.2g, vertical <0.1g
Installation location Outdoor

Solutions for SF6 Live Tank Circuit Breaker OEM

  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor InstallationIn high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues: Pollution & Insulation Degradation Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach Class IV, resulting in insufficient creepage distance and triggering flashov
  • Rockwill Company's SF6 Circuit Breaker Solution for Substations in the Ethiopian Highlands
    I.Project BackgroundThe Ethiopian highlands feature high altitudes (average over 2,500 meters), extreme cold climates (winter temperatures as low as -30°C), and location within the seismically active East African Rift Zone. These conditions pose significant challenges to power equipment: SF6 Liquefaction Risk: At 0.6 MPa operating pressure, SF6 gas liquefies at -25°C. Extreme cold may cause liquefaction, leading to degraded insulation and loss of arc-extinguishing capability. Seismic Threats: Th
  • Rockwill's SF6 Circuit Breaker Solution for 33kV Substations in Nigeria
    Project BackgroundNigeria’s tropical climate, characterized by year-round high temperatures (annual average of 35°C) and humidity (≥80%), poses significant challenges to the sealing integrity, insulation performance, and gas management of electrical equipment. Rockwill was contracted to upgrade a 33kV substation, deploying its proprietary HV-type SF6 circuit breaker to address critical issues: Sealing Failure Risks: Accelerated aging of seals due to heat and water ingres
  • SF6 Circuit Breaker Seal Failure Analysis and HNBR Upgrade Strategy for Venezuela 24kV Network
    Core Challenge: The 24kV outdoor SF6 circuit breakers operated by Venezuela's National Electric Corporation (CORPOELEC), under the C5-M high salt mist corrosion environment along the Lake Maracaibo coast and an annual average temperature of 32°C, experience accelerated O-ring compression set, causing the SF6 annual leakage rate to deteriorate from the design value of ≤0.1% to over 1% in actual operation, frequently triggering low-pressure lockout alarms. This is one of the key contributin

Documentation Resource Library SF6 Live Tank Circuit Breaker OEM

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English
Outdoor live tank SF6 circuit breaker
Restricted.
Outdoor live tank SF6 circuit breaker
Catalogue
English
PDF
PDF
RHB-145  Live tank SF6 gas circuit breaker  FLYER
Public.
RHB-145 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-252  Live tank SF6 gas circuit breaker  FLYER
Public.
RHB-252 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-170  Live tank SF6 gas circuit breaker FLYER
Public.
RHB-170 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB Type Live tank SF6 gas circuit breaker
Restricted.
RHB Type Live tank SF6 gas circuit breaker
Catalogue
English
PDF
PDF
RHB-123 Live tank SF6 gas circuit breaker
Public.
RHB-123 Live tank SF6 gas circuit breaker
Drawings
English
RHB-145 Live tank SF6 gas circuit breaker
Public.
RHB-145 Live tank SF6 gas circuit breaker
Drawings
English
RHB-170(m) Live tank SF6 gas circuit breaker
Public.
RHB-170(m) Live tank SF6 gas circuit breaker
Drawings
English
RHB-245 Live tank SF6 gas circuit breaker
Public.
RHB-245 Live tank SF6 gas circuit breaker
Drawings
English
RHB-330kV Live tank SF6 gas circuit breaker
Restricted.
RHB-330kV Live tank SF6 gas circuit breaker
Drawings
English
PDF
PDF
RHB Outdoor SF6 Circuit Breaker  Installation and Operation Instruction
Restricted.
RHB Outdoor SF6 Circuit Breaker Installation and Operation Instruction
Operating Instruction
English
PDF
PDF

FAQ for SF6 Live Tank Circuit Breaker OEM

As an OEM partner, do you support private labeling and specific branding requirements?

Absolutely. We specialize in OEM services and can fully customize the product nameplate, paint color, and even the mechanism box layout to match your brand identity. We ensure the equipment meets your local grid standards while carrying your brand.

How does the equipment perform in areas with heavy pollution or coastal salt mist?

The RHB series is designed with robust porcelain post insulation which offers superior hydrophobicity and pollution resistance compared to composite materials in certain harsh environments. Combined with a low annual SF6 leakage rate (<0.5%), it ensures stable dielectric strength even in challenging outdoor conditions.

Is the spring operating mechanism compatible with existing automation or SCADA systems?

Yes. The CT20 spring mechanism is designed for seamless integration. It supports standard auxiliary contacts for remote signaling and can be equipped with motorized charging and trip/close coils to interface directly with modern substation automation systems for remote control.

What is the warranty period for the RHB Series Circuit Breaker?

We stand behind the quality of our unified high-voltage platform with a 20-year warranty. This reflects our confidence in the robust porcelain insulation, the sealed SF6 system (leakage rate <0.5%), and the durability of the CT-type spring mechanism.

How do you ensure the safety of the SF6 insulation over time?

Safety is monitored via an integrated pointer density relay that provides real-time visualization of the gas status. Combined with an annual leakage rate of less than 0.5% and a maintenance cycle of up to 30 years, the system guarantees consistent dielectric strength throughout its service life.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO