Live tank SF6 gas circuit breaker 40.5kV to 362kV

  • Live tank SF6 gas circuit breaker 40.5kV to 362kV

Key attributes

Brand ROCKWILL
Series RHB
Rated voltage 40.5kV/52kV/123kV/145kV/363kV
Rated current up to 4000A
Rated peak withstand current up to 158kA
Rated frequency 50/60Hz

Description

The RHB type Live tank SF6 gas circuit breaker is specifically designed for outdoor high - voltage environments. Utilizing self - blast arc - extinguishing technology and taking advantage of the excellent insulating and arc - extinguishing properties of SF₆ gas。

It can quickly quench arcs, ensuring the efficient interruption of fault currents. With a compact and robust structure, it can adapt to various harsh weather conditions. 

It boasts high reliability and a long service life, which can significantly reduce maintenance frequency, making it a key device for enhancing the safety and stability of power systems.

Main function introduction:

  • SF6 gas is used for arc extinguishing

  • Monitor with a pointer-type density relay

  • Adopt the self-blast arc extinguishing principle

  • Adopt pointer-type density relays for pressure and density monitoring

Technology parameters:

RHB-52

Item Unit Parameter
Rated voltage kV 52
Rated frequency Hz 50/60
Rated current A up to 4000
Rated short-time withstand current, up to 3 s kA up to 63
Rated peak withstand current kA up to 158
Rated short-duration power-frequency withstand voltage, 1 min kV 95
Power-frequency withstand voltage, 1 min across open contacts kV 95
Rated lightning impulse withstand voltage, 1.2/50 μs kV 200
Rated lightning impulse withstand voltage, 1.2/50 μs, across open contacts kV 250
Rated filling pressure (abs. at 20 °C) circuit-breaker/other components MPa 0.5
Minimum functional pressure (abs. at 20 °C) circuit-breaker/other components MPa 0.4

RHB-123/145

Item Unit 123kV 145kV
Rated voltage kV 123 145
Rated frequency Hz 50/60
Rated current A up to 4000
Rated short-time withstand current, up to 3 s kA up to 63
Rated peak withstand current kA up to 158
Rated short-duration power-frequency withstand voltage,1min kV 230 275
Power-frequency withstand voltage,1min across open contacts kV 265 315
Rated lightning impulse withstand voltage,1.2/50 μs kV 550 650
Rated lightning impulse withstand voltage,1.2/50 μs,across open contacts kV 650 750
Rated filling pressure (abs. at 20℃) circuit-breaker MPa 0.6
Minimum functional pressure (abs. at 20℃) circuit-breaker MPa 0.5
Temperature range (ambient) -30~+40
Type of installation — outdoor
Partial discharge capacity pC <5
SF₆ leakage rate per year — <0.5%
Maintenance cycle Year 30

RHB-363 

Item Unit Parameter
Rated voltage kV 362
Rated frequency Hz 50/60
Rated current A up to 4000
Rated short-time withstand current, up to 3 s kA up to 63
Rated peak withstand current kA 158
Rated short-duration power-frequency withstand voltage, 1 min kV 450
Power-frequency withstand voltage, 1 min across open contacts kV 520
Rated lightning impulse withstand voltage, 1.2/50  μs kV 1175
Rated lightning impulse withstand voltage, 1.2/50 μs, across open contacts kV 1380
Rated filling pressure (abs. at 20 ℃) circuit-breaker MPa 0.6
Minimum functional pressure (abs. at 20 ℃) circuit-breaker MPa 0.5

Device structure:

RHB-40.5

RHB type Live tank SF6 gas circuit breaker.png

RHB-72.5

72.5kV RHB type Live tank SF6 gas circuit breaker.jpg

RHB-123/145

123/145kV RHB type Live tank SF6 gas circuit breaker.jpg

 

RHB-170

170kV RHB type Live tank SF6 gas circuit breaker.jpg

RHB-252

 

252kV RHB type Live tank SF6 gas circuit breaker.jpg

RHB-362

363kV RHB type Live tank SF6 gas circuit breaker.png

 

Solutions for Live tank

  • SF6 Circuit Breaker Seal Failure Analysis and HNBR Upgrade Strategy for Venezuela 24kV Network
    Core Challenge: The 24kV outdoor SF6 circuit breakers operated by Venezuela's National Electric Corporation (CORPOELEC), under the C5-M high salt mist corrosion environment along the Lake Maracaibo coast and an annual average temperature of 32°C, experience accelerated O-ring compression set, causing the SF6 annual leakage rate to deteriorate from the design value of ≤0.1% to over 1% in actual operation, frequently triggering low-pressure lockout alarms. This is one of the key contributin

Documentation Resource Library Live tank

RHB-330kV Live tank SF6 gas circuit breaker
Restricted.
RHB-330kV Live tank SF6 gas circuit breaker
Drawings
English
Consulting
Consulting
RHB Type Live tank SF6 gas circuit breaker 11kV…550kV
Restricted.
RHB Type Live tank SF6 gas circuit breaker 11kV…550kV
Catalogue
English
Consulting
Consulting
RHB-52 Live tank SF6 gas circuit breaker FLYER
Public.
RHB-52 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-170  Live tank SF6 gas circuit breaker FLYER
Public.
RHB-170 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-252  Live tank SF6 gas circuit breaker  FLYER
Public.
RHB-252 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-145  Live tank SF6 gas circuit breaker  FLYER
Public.
RHB-145 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB-72.5 Live tank SF6 gas circuit breaker FLYER
Public.
RHB-72.5 Live tank SF6 gas circuit breaker FLYER
Brochure
English
RHB Hybird Switchgear Catalog
Restricted.
RHB Hybird Switchgear Catalog
Selection Guide
English
Consulting
Consulting

FAQ for Live tank

Q: What applications are a live tank breaker and a dead tank breaker each best suited for?
A:

 Live tank breakers are well-suited for outdoor high-voltage distribution with a dispersed layout. Dead tank breakers flexibly adapt to both indoor and outdoor applications, especially in space-constrained substations or where compact installation is required.

Q: Where is the arc extinguishing chamber located in a live tank breaker versus a dead tank breaker?
A:

In a live tank breaker, the arc chamber is mounted at the top or side of the column, exposed to ambient air. In a dead tank breaker, the arc chamber is placed inside the metal tank, fully sealed.

Q: What is the fundamental difference between a vacuum circuit breaker (VCB) and an SF₆ circuit breaker?
A:

The core difference is the arc-extinguishing medium. A VCB uses a high vacuum inside a sealed ceramic or glass envelope — the vacuum rapidly diffuses ions and metal vapor after current zero, achieving arc extinction in <10 ms. An SF₆ CB uses sulfur hexafluoride gas, which has strong electron affinity — it captures free electrons to form heavy negative ions, quickly depleting the arc channel's conductivity.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO