IEC Oil-Immersed Zigzag Earthing Transformer Manufacturer-11kV to 35kV

  • IEC Oil-Immersed Zigzag Earthing Transformer Manufacturer-11kV to 35kV
  • IEC Oil-Immersed Zigzag Earthing Transformer Manufacturer-11kV to 35kV

Key attributes

Brand ROCKWILL
Series JDS
Rated voltage 24 kV
Rated neutral current Up to 3000 A
Rated frequency 50 / 60 Hz

Description

Rockwill three-phase oil-immersed zigzag earthing transformers are engineered to provide a stable artificial neutral point for medium-voltage power systems. Featuring a fully sealed oil-immersed structure with optimized zigzag (ZNyn) winding, these transformers provide stable neutral grounding for ungrounded or low-current grounded systems from 11 kV to 35 kV.
They effectively suppress arc grounding overvoltage, limit ground fault currents, and enhance grid stability. Manufactured in compliance with IEC standards, these units are suitable for distribution networks, industrial facilities, and utility substations.
 Earthing Transformer Manufacturer

Product Showcase Video

Key Features

  • Medium-Voltage Neutral Grounding: Creates an artificial neutral for ungrounded or delta-connected 11~35kV systems, compatible with arc suppression coils and neutral grounding resistors.
  • Optimized Z-Type Winding: Zigzag (ZNyn) winding configuration delivers low zero-sequence impedance, ensuring efficient fault current path and sensitive relay protection.
  • Oil-Immersed Fully Sealed Construction:Durable sealed tank design with mineral oil insulation ensures long service life, strong overload capacity, and maintenance-free outdoor operation.
  • Flexible Cooling Options:Available with ONAN or ONAF cooling systems to match application load profiles and ambient conditions.
  • Customizable Secondary Winding:Optional 0.4 kV auxiliary winding enables dual use as station service transformer, supplying local LV loads.

Technical Parameters

Parameter Value
Highest voltage for equipment (Um) 12 / 24 / 36 / 40.5 kV
Rated frequency 50 / 60 Hz
Number of phases Three
Connection group ZNyn11
Rated neutral current Up to 3000 A (customizable)
Rated short-time duration 10 s / 30 s / 60 s (customizable)
Zero-sequence impedance (Zo) Per project specification (tolerance ≤ ±10 %)
Cooling method ONAN / ONAF
Insulation medium Mineral oil
Auxiliary winding Optional 0.4 kV, up to 500 kVA
Ambient temperature –25 °C to +40 °C
Installation Indoor or outdoor
Enclosure options IP-rated cabinet; optional CT, VT, or isolation switch

Insulation Levels by Voltage Class

System Voltage Um (kV) PF (kV) LI (kV)
11 kV 12 28 75
20 kV 24 50 125
22 kV 24 50 125
30 kV 36 70 170
33 kV 36 70 170
35 kV 40.5 95 200

Type Test

Temperature rise test is one of the mandatory type tests for oil-immersed earthing transformers, to verify the winding and oil temperature rise under rated neutral current condition. The diagram below shows the single-phase energizing wiring scheme for temperature rise test of ZNyn11 earthing transformer. This special test connection simulates the zero-sequence fault operating condition, to heat the windings and check whether the temperature rise complies with IEC limits.

Temperature rise test verifies thermal performance of the earthing transformer under neutral fault current. The wiring diagram illustrates the single-phase injection test connection for temperature rise measurement, which is adopted for type test according to IEC 60076-6.

IEC Oil-Immersed Zigzag Earthing Transformer Manufacturer-11kV to 35kV

Figure: Earthing transformer temperature rise test wiring

Applications

  • Medium-voltage distribution network neutral grounding (11 kV – 35 kV)
  • Wind farm and photovoltaic power station grid connection
  • Railway traction power supply systems
  • Industrial and mining enterprise power distribution
  • Regional substation grounding protection projects
  • Urban power grid upgrading and renovation

Standards

  • IEC 60076-6 — Power transformers – Part 6: Reactors (grounding transformer requirements)
  • IEC 60076-1 — Power transformers (general)
  • IEC 60071-1 — Insulation coordination
  • ISO 9001 — Quality management system

Request Custom Quotation

Please provide your requirements: system voltage, rated neutral current, short-time withstand time, connection group (ZN / ZNyn11), cooling method and ambient condition. Our engineering team will send you technical proposal and quotation promptly.

Solutions for Earthing Transformer Manufacturer

  • Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid Stability
    Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid StabilityZig-Zag transformers (also known as Z-connected grounding transformers) offer significant advantages in Southeast Asian power systems due to their unique design, which addresses tropical climates, grid structures, and development needs. Below is an analysis of their core benefits and application scenarios:I. Cost Efficiency & Space Optimization Low-Cost SolutionSimplified constructio
  • Oil-Immersed Grounding Transformer for Chile’s Mining and Renewable Energy Networks
    Chile has one of the more developed power standards systems in South America, with a grid architecture shaped by its unique geography. The northern mining and renewable energy hubs, such as the Atacama Desert PV clusters, commonly operate at 34.5kV or 23kV medium-voltage levels, under demanding environmental conditions. To address high altitude, high salinity, intense solar radiation and long-distance transmission, Rockwill provides customized oil-immersed grounding transformer solutions. This s
  • Earthing Transformer Solution for Egypt’s Distribution Network
    As a major economy in North Africa, Egypt’s power system is facing growing pressure from rapid urbanization and industrialization. In core cities such as Cairo and Alexandria, as well as in the Suez Canal Economic Zone, the distribution network relies heavily on cable systems with high capacitive earth fault currents. Many areas are also located near desert environments, where operating conditions are harsh.1.  Challenge AnalysisTechnical challengesHigh wind-blown sand, large day-night temperatu
  • Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding Transformers
    Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding TransformersZ-type grounding transformers are critical for stabilizing ungrounded or delta-connected power systems by providing a low-impedance path for zero-sequence currents during faults. Integrating intelligent maintenance and sustainability practices enhances their reliability while minimizing environmental impact. Below is a structured analysis of advanced solutions:I. Intelligent Maintenance Services Real-Time

Documentation Resource Library Earthing Transformer Manufacturer

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

FAQ for Earthing Transformer Manufacturer

What is the main difference between Rockwill Zig-zag earthing transformer and ordinary three-phase transformer repurposed for neutral grounding?
Item Rockwill Zig-zag Earthing Transformer Ordinary 3-phase transformer repurposed for neutral grounding
Winding Dedicated Zig-zag ZN winding, high impedance for positive/negative sequence, low & stable zero-sequence impedance; zero-sequence flux closes within core limbs Standard YNd/YNy winding. Zero-sequence flux travels through tank/clamp, creating extra losses and uncontrolled Z0
Purpose Designed to create artificial neutral point for short-time single-phase earth fault duty Designed for power transformation, not earth-fault duty
Fault withstand Custom short-time fault current & duration (typical 10s/30s/60s) per project Limited zero-sequence loading. Engineering experience shows the matched Petersen coil capacity is generally limited to 20% of transformer rating, with risk of local overheating
Package Native compatible with arc suppression coil / neutral earthing resistor cabinet Requires heavy modification for neutral earthing, high engineering risk
Standard IEC 60076-6, type test verified for earthing duty General power transformer standard, no dedicated earth-fault verification

Summary: Repurposed ordinary three-phase transformers are NOT recommended for MV distribution neutral earthing. Rockwill Zig-zag earthing transformer is purpose-built for short-time single-phase earth faults with stable zero-sequence characteristics, offering reliable artificial neutral point for distribution networks.

Can Rockwill provide OEM / ODM earthing transformer service for local partners and system integrators?

Yes. Rockwill support full OEM / ODM cooperation. We select partners rigorously, prioritizing system integrators with power engineering capability, local delivery and after-sales service. Ideal partners are not only distributors, but also capable of local technical support to jointly deploy neutral earthing packages.

Does Rockwill offer long-term warranty for earthing transformer, and what is covered under warranty?

Rockwill provides industry-leading warranty for earthing transformers:

10-year+ full-unit warranty covering core, ZN windings, tank/enclosure and sealing components.

We offer free repair or replacement of defective parts for failures caused by material or manufacturing defects within warranty period. Damage caused by human error, system overvoltage or operation exceeding the nameplate short-time fault duty is excluded. Terms are clear with no hidden clauses.

This guarantee is backed by years of design and field operation experience for neutral earthing packages. Most competitors only offer standard 1–2 year warranty. Earthing transformers operate under short-time fault duty. Rockwill’s extended warranty demonstrates confidence in winding insulation and structural reliability.

Does Rockwill have a cost-effective economical version of earthing transformer for budget-limited distribution projects?

Rockwill’s economical earthing transformer variant. It retains the core Zig-zag ZN winding structure to create artificial neutral point, with basic temperature monitoring as standard.
Cost optimization can be achieved via the following downgrade options:

  • Downgrade insulation class from Class H to Class F
  • Remove remote temperature sensors, keep local temperature measurement only
  • Simplify enclosure IP rating according to site environment
  • Remove integrated PT/CT; customers may use external instrument transformers

The solution cuts unnecessary features while guaranteeing required neutral earthing function and compliance to reduce capital expenditure.

How does Rockwill earthing transformer compare with other well-known brands in the medium voltage earthing transformer market?

Rockwill Zig-zag (ZN connection) earthing transformers compete with global leading brands including Hitachi Energy, Schneider Electric and GE Vernova in technology, configuration and package delivery.

  • Core: Cold-rolled oriented silicon steel, low loss & low noise
  • Winding: Dedicated Zig-zag (ZN) winding with controllable zero-sequence impedance, tolerance ≤ ±10%
  • Insulation class: Class F / Class H optional (oil-immersed / dry type)
  • Package options: Integrated packages with arc suppression coil, neutral earthing resistor cabinet, built-in PT/CT available; many competitors supply only transformer unit separately
  • Grades: Economy / Standard / Heavy-duty short-time withstand version
  • Certifications: IEC 60076-6, IEC 60076-1, IEEE C57.32 and other national standards on request, full type test reports supplied

Key difference: Rockwill customizes zero-sequence impedance and short-time fault current precisely according to system capacitive current, supporting standalone unit or complete neutral earthing package. Customers select configurations only for actual requirements without overpaying for redundant performance.

What are the standards for the "fault withstand time" of earthing/grounding transformers, and how to match them during selection?

Fault withstand time is the maximum duration an earthing transformer can endure fault-current thermal and mechanical stresses under rated short-time capacity, with standard durations of 10s, 30s, 60s, or 1 hour per IEEE 32/IEC 60076‑5. Selection must ensure withstand time ≥ protection clearing time plus redundancy—e.g., a 15‑second relay trip requires a 30‑second withstand rating to prevent damage.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO