Customized Neutral Grounding Transformer Manufacturer-33kV

  • Customized Neutral Grounding Transformer Manufacturer-33kV

Key attributes

Brand ROCKWILL
Series JDS
Rated voltage 33kV
Rated neutral current Up to 3000 A
Rated frequency 50 / 60 Hz

Description

Rockwill’s three-phase oil-immersed zigzag earthing transformer is designed for medium-voltage networks that do not have a natural neutral point. By creating a reliable artificial neutral, it allows arc suppression coils, neutral grounding resistors and protection devices to be connected safely and effectively.
The transformer uses an optimized ZN or ZNyn11 winding arrangement inside a fully sealed oil tank. Under normal operation, it draws very little current. During a single-phase earth fault, it provides a low zero-sequence impedance path so fault current can return through the neutral point. This helps limit fault current, suppress arc-grounding overvoltage and improve relay protection sensitivity.

Why This Transformer Fits MV Grounding Systems?

  • Provides an artificial neutral point for ungrounded, impedance-grounded or delta-connected systems
  • Supports stable connection of neutral grounding resistors and arc suppression coils
  • Limits ground fault current to a controllable level
  • Improves earth-fault detection and relay coordination
  • Fully sealed oil-immersed design suitable for outdoor and long-term service
  • Customizable neutral current, short-time rating and zero-sequence impedance

Typical System Benefits

System Need Transformer Contribution
No neutral point available Creates a stable artificial neutral
High arc-grounding overvoltage risk Provides a controlled zero-sequence path
Weak earth-fault protection Enables sensitive relay operation
Outdoor substation installation Sealed oil tank reduces maintenance
Dual-purpose requirement Optional auxiliary winding can supply LV station service

 Robust Sealed Construction & Component Layout

As shown in the image, the unit features a fully sealed welded tank design, eliminating the need for an oil conservator and preventing moisture ingress for maintenance-free operation.

  • High-Voltage Bushings: The four robust porcelain/polymer bushings demonstrate a high-insulation design suitable for various medium-voltage applications, ensuring safety against flashover.
  • Efficient Cooling: Visible corrugated fin radiators maximize the heat dissipation surface area, supporting stable operation under full load.
  • Safety Accessories: Equipped with pressure relief devices and thermometer pockets on the tank cover for real-time internal monitoring and grid safety.

Three Phase Oil-Immersed Neutral Earthing Transformer Custom Factory-33kV

Design Highlights

  • ZN / ZNyn11 Zigzag Winding:Low zero-sequence impedance enables effective fault current return while keeping normal operating current minimal.
  • Fully Sealed Oil-Immersed Tank:Mineral oil insulation and sealed construction help protect the transformer from moisture, oxygen and environmental contamination.
  • Custom Short-Time Rating:Neutral current can be specified up to 3000 A with short-time durations of 10 s, 30 s or 60 s.
  • Flexible Cooling:Available with ONAN or ONAF cooling depending on site load and ambient conditions.
  • Optional Auxiliary Winding:A 0.4 kV auxiliary winding can be added for station service or local low-voltage supply.

Product Showcase Video

Technical Parameters

Parameter Value
Highest voltage for equipment (Um) 36 kV
Rated frequency 50 / 60 Hz
Number of phases Three
Connection group ZN (zigzag) / ZNyn11
Rated capacity Customizable (per project specification)
Rated neutral current Up to 3000 A
Rated short-time duration 10 s / 30 s / 60 s (customizable)
Zero-sequence impedance (Zo) Per project specification (tolerance ≤ ±10 %)
Cooling method ONAN / ONAF
Insulation medium Mineral oil
Auxiliary winding Optional (0.4 kV)
Ambient temperature –25 °C to +40 °C
Installation Indoor or outdoor
Enclosure options IP-rated cabinet; optional CT, VT, or isolation switch

Insulation Level

System Voltage Um (kV) PF (kV) LI (kV)
33 kV 36 70 170

Environmental Conditions

Item Value
Max ambient air temperature +40°C
Max 24h average ambient air temperature +35°C
Min ambient air temperature -25°C
Altitude ≤ 1000 m
Max relative humidity(24h average) ≤ 95%
Max relative humidity(1 month average) ≤ 90%
Max water vapor pressure(24h average) 2.2 kPa
Max water vapor pressure(1 month average) 1.8 kPa
Solar radiation ≤ 1000 W/m²
Pollution level II

Suitable Applications

  • Medium-voltage distribution network grounding
  • Wind farm and PV plant grid connection
  • Railway traction power systems
  • Industrial and mining power distribution
  • Regional substation grounding protection
  • Urban power grid upgrading

Standards

  • IEC 60076-6 — Power transformers – Part 6: Reactors (grounding transformer requirements)
  • IEC 60076-1 — Power transformers (general)
  • IEC 60071-1 — Insulation coordination
  • ISO 9001 — Quality management system

How to Request a Quotation?

Please provide:
  • System voltage and Um
  • Required neutral current and short-time rating
  • Target zero-sequence impedance
  • Cooling method preference
  • Indoor or outdoor installation
  • Need for auxiliary winding
  • Required accessories such as CT, VT, cabinet or isolation switch

Solutions for Grounding Transformer Manufacturer

  • Oil-Immersed Grounding Transformer for Chile’s Mining and Renewable Energy Networks
    Chile has one of the more developed power standards systems in South America, with a grid architecture shaped by its unique geography. The northern mining and renewable energy hubs, such as the Atacama Desert PV clusters, commonly operate at 34.5kV or 23kV medium-voltage levels, under demanding environmental conditions. To address high altitude, high salinity, intense solar radiation and long-distance transmission, Rockwill provides customized oil-immersed grounding transformer solutions. This s
  • Earthing Transformer Solution for Egypt’s Distribution Network
    As a major economy in North Africa, Egypt’s power system is facing growing pressure from rapid urbanization and industrialization. In core cities such as Cairo and Alexandria, as well as in the Suez Canal Economic Zone, the distribution network relies heavily on cable systems with high capacitive earth fault currents. Many areas are also located near desert environments, where operating conditions are harsh.1.  Challenge AnalysisTechnical challengesHigh wind-blown sand, large day-night temperatu
  • Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding Transformers
    Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding TransformersZ-type grounding transformers are critical for stabilizing ungrounded or delta-connected power systems by providing a low-impedance path for zero-sequence currents during faults. Integrating intelligent maintenance and sustainability practices enhances their reliability while minimizing environmental impact. Below is a structured analysis of advanced solutions:I. Intelligent Maintenance Services Real-Time

Documentation Resource Library Grounding Transformer Manufacturer

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

Certifications Grounding Transformer Manufacturer

FAQ for Grounding Transformer Manufacturer

What routine maintenance items are required for fully‑sealed oil‑immersed earthing transformers?

Although fully‑sealed oil‑immersed design reduces daily maintenance workload, regular visual and preventive checks are still recommended.

For on‑site routine inspection, operators should observe oil level indicator to keep oil within normal range, check for oil leakage at weld seams, flange and valve positions, inspect porcelain/composite bushing surface for dirt, crack or tracking discharge traces, verify reliable earthing connection of tank shell. For annual preventive maintenance, oil‑sampling test including dielectric strength is suggested, tightening high‑voltage terminal connections, cleaning insulator surface dirt.

Since earthing transformer operates mostly under no‑load status in normal grid condition, most failures only reveal themselves under actual earth‑fault events, so visual check of external components forms the major part of daily care. Major internal disassembly is generally not required for sealed units under normal service life.

What is the difference in application scenarios between oil‑immersed and dry‑type earthing transformers?

Oil‑immersed earthing transformer uses mineral oil as insulation and cooling medium. It features strong overload capability, good heat dissipation performance and competitive unit cost, well‑suited for outdoor substations, wind‑solar power plants, mining and industrial field sites where fire‑safety restriction is not extremely strict.

Fully‑sealed tank construction supports long‑term maintenance‑free outdoor operation. Dry‑type earthing transformer adopts cast‑resin insulation without combustible mineral oil, mainly applied for indoor locations with strict fire‑protection requirements such as urban underground substations, data‑center auxiliary power houses.

Dry‑type units normally come with higher procurement cost and relatively limited overload margin. There is no absolute good‑or‑bad between two types; selection should balance fire risk, installation location, budget and local specification requirements.

What special design adjustments are required for high‑altitude or heavy‑pollution coastal sites?

Standard design is validated for altitude up to 1000 m and pollution class II. When equipment is deployed above 1000 m, air dielectric strength decreases with altitude.

It requires increased creepage and clearance distance for high‑voltage bushings, together with corresponding insulation derating. For coastal locations with heavy salt fog, anti‑salt‑fog composite bushings and enhanced anti‑corrosion painting for the whole tank structure will be adopted.

Cooling performance also degrades under high‑altitude low‑air‑density environment, so thermal derating calculation will be completed accordingly.

These environmental modifications are completed during factory production phase instead of on‑site retrofitting, so special operating conditions should be notified at technical clarification stage.

What key site‑specific information do I need to provide for proper earthing transformer quotation and design?

To deliver a fully‑matched technical proposal, several core site parameters should be shared at the early project stage.

Apart from system nominal voltage, you need to provide the measured or calculated total system capacitive earth fault current, selected neutral earthing scheme whether resonant earthing with arc‑suppression coil or resistive earthing with neutral grounding resistor, relay protection operating time which defines required short‑time fault duration.

In addition, actual site environmental conditions including altitude, maximum and minimum ambient temperature, pollution level, relative humidity, installation location indoor or outdoor should be clarified.

If auxiliary station‑service power is required, the load kVA value for secondary winding shall also be specified. Complete site data helps avoid under‑specification or over‑engineering, ensuring the equipment fits local grid protection coordination requirements.

Why is short‑time duration parameter critical for selecting an earthing transformer?

Earthing transformers are designed for short‑time fault duty rather than continuous earth‑fault operation. The short‑time duration defines how long the unit can safely sustain full rated neutral fault‑current without over‑heating.

Rockwill offers standard options of 10 s / 30 s / 60 s. This time setting must be coordinated with your whole‑grid relay‑protection operating time. For example, fast‑tripping resistive‑grounded systems may select 10 seconds, while resonant‑earthed networks with delayed‑fault clearing commonly adopt 30 s or 60 s rating.

Wrong selection of short‑time duration may result in excessive over‑heating risk under actual earth‑fault incidents.

What are the core international standards governing the design, production and testing of earthing/grounding transformers, and what are their respective focuses?

Global standards for grounding transformers fall into IEEE and IEC systems. IEEE 32 (North America) emphasizes fault withstand capability and zero-sequence impedance, while IEC 60076 series covers winding design, insulation, cooling, and short-circuit tests. Chinese standards follow IEC with additional grid-specific requirements on efficiency, temperature rise, and harmonics.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO