Oil-Immersed Neutral Grounding Transformer OEM ODM 17.5kV-40.5kV

  • Oil-Immersed Neutral Grounding Transformer OEM ODM 17.5kV-40.5kV

Key attributes

Brand ROCKWILL
Model NO. Oil-Immersed Neutral Grounding Transformer OEM ODM 17.5kV-40.5kV
Rated voltage 33kV
Rated frequency 50/60Hz
Rated capacity 800kVA
Series JDS

Description

Rockwill three-phase oil-immersed Z-type earthing transformers are engineered for medium-voltage power systems that require a stable artificial neutral point. With an optimized zigzag (ZN) winding and a fully sealed oil-immersed tank, these units provide reliable neutral grounding for ungrounded or resistance-grounded networks between 17.5 kV and 40.5 kV.
They limit ground fault currents, suppress arc grounding overvoltage, and improve relay protection sensitivity. Designed and manufactured in compliance with IEC standards, they are suitable for utility distribution networks, industrial plants, commercial facilities, and renewable energy power systems.

Why a Z-Type Earthing Transformer Is Needed?

In ungrounded or delta-connected medium-voltage systems, there is no natural neutral point for ground fault current to return. A single-phase earth fault may therefore remain undetected, allowing transient overvoltage, insulation stress, and potential escalation to phase-to-phase faults.
A Z-type zigzag earthing transformer creates an artificial neutral point with low zero-sequence impedance. During a ground fault, it provides a controlled current path so that protective relays can detect and isolate the fault quickly. The neutral point can also be connected to a neutral grounding resistor or arc suppression coil for selective earthing.

Product Showcase Video

Key Features

  • Stable Artificial Neutral Point:Provides a reliable neutral for ungrounded or resistance-grounded MV systems, enabling connection of neutral grounding resistors or arc suppression coils.
  • Optimized Z-Type Zigzag Winding:The ZN winding configuration delivers low zero-sequence impedance, ensuring an efficient fault current path and sensitive relay protection.
  • Fully Sealed Oil-Immersed Construction:A durable sealed mineral-oil tank isolates the insulation from air and moisture, improving service life, overload capability, and outdoor reliability.
  • Customizable Capacity Range:Rated capacity from 30 kVA to 3000 kVA, configurable to match system grounding requirements.
  • Optional LV Auxiliary Winding:An integrated secondary winding at 200–440 V can be provided for station service power supply.
  • IEC-Compliant Design:Manufactured in accordance with IEC 60076-6, IEC 60076-1, and ISO 9001 requirements.

Technical Parameters

Parameter Value
Highest voltage for equipment (Um) 17.5 / 24 / 36 / 40.5 kV
Rated frequency 50 / 60 Hz
Number of phases Three
Connection group ZN (zigzag)
Rated capacity 30 – 3000 kVA (customizable)
Winding material Copper or aluminum (customizable)
Cooling method ONAN (oil natural air natural)
Insulation medium Mineral oil
Auxiliary winding Optional (200 V – 440 V)
Installation Indoor or outdoor
Standards compliance IEC 60076-6, IEC 60076-1, ISO 9001

Insulation Levels by Voltage Class

System Voltage Um (kV) PF (kV) LI (kV)
15 kV 17.5 38 95
20 kV 24 50 125
22 kV 24 50 125
30 kV 36 70 170
33 kV 36 70 170
35 kV 40.5 95 200

Environmental Conditions

Max ambient air temperature +40°C
Max 24h average ambient air temperature +35°C
Min ambient air temperature -25°C
Altitude ≤ 1000 m
Max relative humidity (24h average) ≤ 95%
Max relative humidity (1 month average) ≤ 90%
Max water vapor pressure (24h average) 2.2 kPa
Max water vapor pressure (1 month average) 1.8 kPa
Solar radiation ≤ 1000 W/m²
Pollution level II

Applications

  • Medium-voltage distribution network neutral grounding
  • Industrial plant power distribution with resistance-grounded systems
  • Utility substations and switching stations
  • Commercial and institutional building power systems
  • Renewable energy power collection and grid connection

Manufacturing Capabilities

Zigzag Earthing Transformer Manufacturer

Grounding Transformer OEM China

 

Request a Protection-Ready Quote

Provide your Um, target zero-sequence impedance, capacity, cooling and mounting environment — Rockwill engineers respond with a coordinated datasheet, drawing and commercial quotation.

Solutions for Grounding Transformer OEM

  • Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid Stability
    Southeast Asia Power Solutions: Zig-Zag Grounding Transformer for Cost-Effective & Reliable Grid StabilityZig-Zag transformers (also known as Z-connected grounding transformers) offer significant advantages in Southeast Asian power systems due to their unique design, which addresses tropical climates, grid structures, and development needs. Below is an analysis of their core benefits and application scenarios:I. Cost Efficiency & Space Optimization Low-Cost SolutionSimplified constructio
  • Oil-Immersed Grounding Transformer for Chile’s Mining and Renewable Energy Networks
    Chile has one of the more developed power standards systems in South America, with a grid architecture shaped by its unique geography. The northern mining and renewable energy hubs, such as the Atacama Desert PV clusters, commonly operate at 34.5kV or 23kV medium-voltage levels, under demanding environmental conditions. To address high altitude, high salinity, intense solar radiation and long-distance transmission, Rockwill provides customized oil-immersed grounding transformer solutions. This s
  • Earthing Transformer Solution for Egypt’s Distribution Network
    As a major economy in North Africa, Egypt’s power system is facing growing pressure from rapid urbanization and industrialization. In core cities such as Cairo and Alexandria, as well as in the Suez Canal Economic Zone, the distribution network relies heavily on cable systems with high capacitive earth fault currents. Many areas are also located near desert environments, where operating conditions are harsh.1.  Challenge AnalysisTechnical challengesHigh wind-blown sand, large day-night temperatu

Documentation Resource Library Grounding Transformer OEM

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

Certifications Grounding Transformer OEM

FAQ for Grounding Transformer OEM

What inspection and acceptance items should be checked when receiving the transformer on site?

Upon arrival, the first step is visual inspection for tank deformation, paint damage, oil leakage on welds, flanges and valve connections.

The nameplate data should be cross-checked against the technical datasheet, including winding material, rated neutral current, zero-sequence impedance tolerance, auxiliary winding voltage and cooling method.

The oil level gauge reading and sealing status need confirmation. Before energization, routine field tests are recommended: winding resistance, vector group verification, insulation resistance and dielectric loss measurement.

If it is equipped with an auxiliary winding, no-load voltage test should be carried out to verify the low-voltage output. All factory test certificates shall be kept for local grid inspection and audit.

Can this earthing transformer be used in switching stations without local generation?

Yes, it is fully suitable for standalone switching stations and distribution switching points with no generators. Switching stations often split long overhead cable feeders and require a neutral point for the whole section of network to detect earth faults and suppress transient overvoltage.

Even without onsite power generation, the ungrounded feeder section still has distributed capacitive earth‑fault current, which needs a dedicated zigzag earthing unit to establish a neutral reference.

The selection process follows the same principle: calculate total feeder capacitance, define target fault current and protection clearing time, then confirm neutral current rating and short‑time withstand capacity.

How do integrated CT, VT and isolation switches benefit a complete earthing protection scheme?

Current transformers and voltage transformers installed together with the earthing transformer supply measured signals for zero‑sequence protection relays, fault recording and insulation monitoring devices. The isolation switch provides a visible break point for safe isolation during maintenance.

When these components are factory‑integrated inside an IP‑rated cabinet, all wiring, polarity checks and insulation tests are finished before shipment. This reduces site wiring errors, cuts field commissioning time and removes the risk of mismatched polarity between transformer and protection sensors.

It also simplifies civil layout, as contractors receive a single pre‑tested unit rather than multiple separate pieces of equipment that need to be aligned on site.

Why are zigzag winding transformers widely preferred for renewable energy grid‑connection projects?

Solar and wind farm collection networks are mostly ungrounded or low‑current grounded medium‑voltage systems with large distributed capacitance to earth. A zigzag winding provides a dedicated low‑impedance zero‑sequence path, which enables reliable earth fault detection and controlled fault current.

Unlike wye‑delta earthing schemes, the zigzag design presents high impedance to balanced positive‑sequence operating currents under normal operation, so it consumes very little no‑load magnetizing loss and does not disturb normal power delivery.

It can work smoothly with either resonant arc suppression coils or resistive grounding cabinets, adapting to different grid codes issued by power utilities for renewable interconnection.

Compact structure and flexible neutral‑current rating also suit the limited footprint inside wind and solar collector substations.

What are the special design requirements for earthing/grounding transformers used on ships or offshore platforms?

Marine/offshore transformers demand salt-spray-resistant insulation, compact oil-free construction, reinforced vibration-proof design (meeting IEC 60076-5 Class 3), customized shipboard voltages/frequencies (e.g., 6.6kV/60Hz) with auxiliary windings for onboard loads, and natural air cooling (KNAN) for reliable enclosed-cabin operation.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO