Three Phase Neutral Grounding Transformer Supplier 15kV-36kV

  • Three Phase Neutral Grounding Transformer Supplier 15kV-36kV

Key attributes

Brand ROCKWILL
Model NO. Three Phase Neutral Grounding Transformer Supplier 15kV-36kV
Rated voltage 36kV
Rated normal current 3000A
Rated frequency 50/60Hz
Series JDS

Description

Rockwill’s three-phase neutral grounding transformers are designed to create a reliable artificial neutral point for medium-voltage power systems between 15 kV and 36 kV. Built with an optimized zigzag (ZN/ZNyn) winding and a fully sealed oil-immersed tank, they provide a safe grounding reference for ungrounded, impedance-grounded, or delta-connected networks.
These units help suppress arc grounding overvoltage, limit ground fault currents, and improve relay protection sensitivity. Manufactured in compliance with IEC standards, they are suitable for distribution networks, industrial plants, renewable energy stations, and utility substations.
Zigzag Earthing Transformer OEM China

How It Works?

In medium-voltage systems without a natural neutral point, a zigzag grounding transformer creates an artificial neutral by interconnecting phase windings on the same core limb. Under normal operating conditions, the transformer draws very little current. During a single-phase earth fault, it provides a low zero-sequence impedance path, allowing fault current to return through the neutral point.
This design enables stable connection of neutral grounding resistors, arc suppression coils, or protection devices, while keeping healthy-phase voltages within acceptable limits.
zigzag earthing transformer working principle diagram
Three Phase Neutral Grounding Transformer Supplier 15kV-36kV

Key Features

  • Stable Artificial Neutral Point:Provides a neutral reference for delta-connected or ungrounded MV systems from 15 kV to 36 kV.
  • Optimized Zigzag Winding:ZN/ZNyn configuration delivers low zero-sequence impedance and accurate fault current distribution.
  • Fully Sealed Oil-Immersed Tank:Hermetically sealed mineral oil construction reduces moisture ingress, oxidation, and maintenance requirements.
  • High Short-Time Fault Capability:Rated neutral current up to 3000 A, with customizable short-time durations of 10 s, 30 s, or 60 s.
  • Flexible Cooling Options:Available with ONAN, ONAF, AN, or AF cooling to match site load and ambient conditions.
  • Optional Auxiliary Winding:An optional 0.4 kV secondary winding can supply local station service loads.

Product Showcase Video

Technical Parameters

Parameter Value
Highest voltage for equipment (Um) 17.5 / 36 kV
Rated frequency 50 / 60 Hz
Number of phases Three
Connection group ZN (zigzag) / ZNyn11
Rated neutral current Up to 3000 A (customizable)
Rated short-time duration 10 s / 30 s / 60 s (customizable)
Zero-sequence impedance (Zo) Per project specification (tolerance ≤ ±10 %)
Cooling method ONAN / ONAF / AN / AF
Insulation medium Mineral oil
Auxiliary winding Optional 0.4 kV
Installation Indoor or outdoor
Enclosure options IP-rated cabinet; optional CT, VT, or isolation switch

Selection Guide

When specifying a neutral grounding transformer, the following parameters should be confirmed:
  • System voltage: 15 kV, 20 kV, 36 kV, or other MV levels up to Um 36 kV.
  • Neutral current and time rating: Typical combinations include 10 s, 30 s, or 60 s, depending on protection coordination.
  • Zero-sequence impedance: Selected according to fault current limitation and relay sensitivity requirements.
  • Cooling method: ONAN for standard outdoor service; ONAF/AF for higher thermal demand.
  • Auxiliary winding: Required when the transformer also supplies LV station service loads.
  • Installation environment: Indoor, outdoor, IP-rated enclosure, or substation integration.

Environmental Conditions

Item Value
Max ambient air temperature +40°C
Max 24h average ambient air temperature +35°C
Min ambient air temperature -25°C
Altitude ≤ 1000 m
Max relative humidity(24h average) ≤ 95%
Max relative humidity(1 month average) ≤ 90%
Max water vapor pressure(24h average) 2.2 kPa
Max water vapor pressure(1 month average) 1.8 kPa
Solar radiation ≤ 1000 W/m²
Pollution level II

Applications

  • Medium-voltage distribution network neutral grounding (15 kV – 36 kV)
  • Wind farm and photovoltaic power station grid connection
  • Railway traction power supply systems
  • Industrial and mining enterprise power distribution
  • Regional substation grounding protection projects
  • Urban power grid upgrading and renovation

Standards

  • IEC 60076-6 — Power transformers – Part 6: Reactors (grounding transformer requirements)
  • IEC 60076-1 — Power transformers (general)
  • IEC 60071-1 — Insulation coordination
  • ISO 9001 — Quality management system

Request a Quote

For 15 kV–36 kV neutral grounding transformer specifications, drawings, or project quotations, contact our MV engineering team with your system voltage, neutral current, short-time rating, and installation requirements.

Solutions for Grounding Transformer Supplier

  • Oil-Immersed Grounding Transformer for Chile’s Mining and Renewable Energy Networks
    Chile has one of the more developed power standards systems in South America, with a grid architecture shaped by its unique geography. The northern mining and renewable energy hubs, such as the Atacama Desert PV clusters, commonly operate at 34.5kV or 23kV medium-voltage levels, under demanding environmental conditions. To address high altitude, high salinity, intense solar radiation and long-distance transmission, Rockwill provides customized oil-immersed grounding transformer solutions. This s
  • Earthing Transformer Solution for Egypt’s Distribution Network
    As a major economy in North Africa, Egypt’s power system is facing growing pressure from rapid urbanization and industrialization. In core cities such as Cairo and Alexandria, as well as in the Suez Canal Economic Zone, the distribution network relies heavily on cable systems with high capacitive earth fault currents. Many areas are also located near desert environments, where operating conditions are harsh.1.  Challenge AnalysisTechnical challengesHigh wind-blown sand, large day-night temperatu
  • Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding Transformers
    Intelligent Maintenance Services and Sustainable Solutions for Z-Type Grounding TransformersZ-type grounding transformers are critical for stabilizing ungrounded or delta-connected power systems by providing a low-impedance path for zero-sequence currents during faults. Integrating intelligent maintenance and sustainability practices enhances their reliability while minimizing environmental impact. Below is a structured analysis of advanced solutions:I. Intelligent Maintenance Services Real-Time

Documentation Resource Library Grounding Transformer Supplier

Rockwill Electric Group Profile
Public.
Rockwill Electric Group Profile
Brochure
English

FAQ for Grounding Transformer Supplier

What is the function of optional 0.4 kV auxiliary winding on this earthing transformer?

The optional 0.4 kV auxiliary winding enables dual‑function operation of the earthing transformer.

Besides its core duty of creating artificial neutral‑point for MV‑network earth‑fault protection, this winding can output low‑voltage power and act as a station‑service transformer to supply local auxiliary loads inside substation sites.

Its maximum available capacity is up to 500 kVA. Please note this auxiliary winding is for station‑service supply only and cannot take priority over the earthing‑protection function under earth‑fault conditions.

If you require this dual‑use function, specify auxiliary‑winding kVA rating during technical clarification phase.

What routine and type‑test documents are supplied for this oil‑immersed earthing transformer?

Every Rockwill earthing transformer is manufactured and tested complying with IEC 60076‑6, IEC 60076‑1, IEC 60071‑1 and ISO 9001 quality‑system requirements.

Before shipment, each unit completes a full set of routine factory tests including winding‑resistance measurement, ratio‑and‑vector‑group verification, zero‑sequence‑impedance measurement, no‑load and load‑loss test, dielectric withstand tests and sealing‑leakage inspection.

Upon customer request, we can provide complete type‑test reports covering short‑time fault‑current withstand, temperature‑rise test and insulation‑co‑ordinatio

Can this oil‑immersed earthing transformer be installed both indoors and outdoors? What points need attention?

Yes, the JDS series supports both indoor and outdoor installation. For outdoor deployment, the fully‑sealed mineral‑oil tank structure works well under all‑weather conditions, and we can supply IP‑rated protective enclosures, external CT/VT and isolating‑switch assemblies as factory‑integrated packages.

If installed indoors, users must guarantee sufficient ventilation for heat dissipation of radiators and comply with local fire‑safety rules for oil‑filled electrical equipment.

Standard environmental baseline covers altitude ≤ 1000 m, pollution class II, ambient temperature from -25 °C to +40 °C. For high‑altitude, heavy salt‑fog coastal or heavily‑polluted sites, please notify us in advance so we can upgrade insulation, creepage distance, anti‑corrosion coating and perform necessary thermal derating design.

Can Rockwill earthing transformer work with both Petersen coil (arc‑suppression coil) and neutral‑grounding resistor NGR?

Absolutely. The JDS‑series zig‑zag earthing transformer is purpose‑built to create an artificial neutral point for delta‑connected or ungrounded medium‑voltage grids.

Its externally‑brought‑out neutral terminal can be connected either to a Petersen coil for resonant‑earthing schemes or to neutral‑grounding resistors (NGR) for resistive‑earthing networks.

When placing an order, please share your system earthing philosophy, target fault‑current magnitude and required short‑time withstand duration. Our engineering team will tune zero‑sequence impedance, rated neutral‑current and short‑time rating to perfectly match your selected neutral‑earthing device.

What advantages does ZNyn11 zigzag winding bring to the earthing transformer?

The specially optimized ZNyn11 zigzag winding structure features low and controllable zero-sequence impedance. When a single-phase earth fault occurs, it can form a smooth fault current loop. This characteristic ensures the relay protection device can detect faults sensitively and act reliably.

Compared with using ordinary power transformers for grounding purposes, this dedicated winding avoids uncontrolled zero-sequence current, extra stray loss and unexpected local overheating risks under earth fault conditions.

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Message
Inquiry
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO